Improved 3D reconstuction of pacemaker leads

被引:0
作者
Williams, BB [1 ]
Esthappan, J [1 ]
Hoffmann, KR [1 ]
机构
[1] Univ Chicago, Dept Radiol MC2026, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
来源
PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING | 1997年 / 19卷
关键词
pacemakers; 3D reconstruction; biplane imaging;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recently, serious health risks to recipients of pacemakers due to the failure and fracture of structural pacemaker components has placed an emphasis on the need for methods of evaluating pacemaker components in vivo. In order to facilitate these evaluations, we have developed methods for determination of the in-vivo 3D positions of pacemaker leads during the entire heart cycle. Sequences of biplane images of patients with pacemakers were obtained at 30 frames/sec for each projection. The sequences usually included at least two heart cycles. After patient imaging, biplane images of a calibration object were obtained from which the biplane imaging geometry was determined. The centerlines of the leads were indicated manually for all acquired images. These lead data were interpolated temporally so that the temporal non-synchronicity of the image acquisition was overcome. Epipolar lines, generated from the calculated geometry, were used to adjust the temporally interpolated data based on known consistencies of simultaneously acquired images. The 3D positions of the leads were then calculated using the calculated geometry and point correspondences between leads in simultaneous projections using an epipolar technique. Calculated results indicate that an accurate estimate of the shapes and positions of pacemaker leads throughout the heart cycle can be determined, providing a reliable basis for the needed stress analysis.
引用
收藏
页码:854 / 856
页数:3
相关论文
共 7 条
[1]   ENDOCARDIAL PACING LEADS - THE GOOD, THE BAD, AND THE UGLY [J].
BRINKER, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (05) :953-954
[2]  
Harrigan Timothy, 1996, Journal of the American College of Cardiology, V27, p345A
[3]   A simple technique for calibrating imaging geometries [J].
Hoffmann, KR ;
Esthappan, J ;
Li, SD ;
Pelizzari, CA .
PHYSICS OF MEDICAL IMAGING: MEDICAL IMAGING 1996, 1996, 2708 :371-376
[4]  
HOFFMANN KR, UNPUB MED PHYSICS
[5]  
HOFFMANN KR, 1997, IN PRESS SPIE, V3034
[6]   ATRIAL J PACING LEAD RETENTION WIRE FRACTURE - RADIOGRAPHIC ASSESSMENT, INCIDENCE OF FRACTURE, AND CLINICAL MANAGEMENT [J].
LLOYD, MA ;
HAYES, DL ;
HOLMES, DR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (05) :958-964
[7]   LIFE-THREATENING DEGENERATION OF THE ACCUFIX ACTIVE-FIXATION ATRIAL-PACING ELECTRODE [J].
SULKE, N ;
CHAMBERS, J ;
BLAUTH, C .
LANCET, 1995, 346 (8966) :25-26