Development and evaluation of an IS711-based loop mediated isothermal amplification method (LAMP) for detection of Brucella spp. on clinical samples

被引:27
|
作者
Perez-Sancho, M. [1 ,2 ]
Garcia-Seco, T. [1 ]
Arrogante, L. [3 ]
Garcia, N. [1 ]
Martinez, I. [1 ]
Diez-Guerrier, A. [2 ]
Perales, A. [3 ]
Goyache, J. [1 ,2 ]
Dominguez, L. [1 ,2 ]
Alvarez, J. [1 ,4 ]
机构
[1] Univ Complutense Madrid, Ctr VISAVET, E-28040 Madrid, Spain
[2] Univ Complutense Madrid, Fac Vet, Dept Sanidad Anim, E-28040 Madrid, Spain
[3] Minist Agr Alimentac & Media Ambiente, Lab Cent Sanidad Anim, Granada 18320, Spain
[4] IRYCIS, Madrid 28034, Spain
关键词
Bacteriology; Brucella; Loop mediated isothermal amplification (LAMP); PCR; POLYMERASE-CHAIN-REACTION; REAL-TIME PCR; ABORTED BOVINE FETUSES; RAPID DETECTION; REEMERGING ZOONOSIS; DNA; MILK; MELITENSIS; BLOOD; SHEEP;
D O I
10.1016/j.rvsc.2013.05.002
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
DNA-based methods have emerged as an additional tool for Brucella infection-confirmation at a herd level. However, their implementation may require the use of specialized equipment. In this context the recently developed loop-mediated isothermal amplification (LAMP) technique may constitute an additional and cost-effective tool for rapid and specific DNA detection, especially in low income areas. In the present study the usefulness of a newly developed LAMP assay aiming at the multicopy-IS711 sequence was assessed on a variety of clinical samples (n = 81 from abortions and ewes; cattle, n = 3; swine, n = 4) that were analyzed in parallel using real-time PCR and bacteriology. Although overall sensitivities obtained with the three methods were comparable (p > 0.05), our results highlighted the complementarity between bacteriology and molecular-based methods for increased sensitivity. Significant differences (p < 0.05) were observed with all techniques depending on the nature of the sample. Our results demonstrate the potential of the IS711-LAMP technique for direct Brucella detection. (c) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:489 / 494
页数:6
相关论文
共 50 条
  • [21] A novel, sensitive, accurate multiplex loop-mediated isothermal amplification method for detection of Salmonella spp., Shigella spp. and Staphylococcus aureus in food
    Jiang, Kan
    Lv, Qinfeng
    Zhang, Donglei
    Gao, Xiang
    Zhao, Yi
    Li, Mengxian
    Liu, Ling
    Wu, Junhua
    Lu, Xiangyi
    Luo, Cheng
    JOURNAL OF FOOD AGRICULTURE & ENVIRONMENT, 2012, 10 (3-4): : 252 - 256
  • [22] Evaluation of molecular inhibitors of loop-mediated isothermal amplification (LAMP)
    Nwe, May Khat
    Jangpromma, Nisachon
    Taemaitree, Lapatrada
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [23] Evaluation of diagnostic accuracy of loop-mediated isothermal amplification method (LAMP) compared with polymerase chain reaction (PCR) for Leptospira spp. in clinical samples: a systematic review and meta-analysis
    Gunasegar, Shan
    Neela, Vasantha Kumari
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2021, 100 (03)
  • [24] Loop-mediated isothermal amplification (LAMP) test for specific and rapid detection of Brucella abortus in cattle
    Karthik, K.
    Rathore, Rajesh
    Thomas, Prasad
    Arun, T. R.
    Viswas, K. N.
    Agarwal, R. K.
    Manjunathachar, H. V.
    Dhama, Kuldeep
    VETERINARY QUARTERLY, 2014, 34 (04) : 174 - 179
  • [25] Establishment of universal loop-mediated isothermal amplification method (LAMP) for rapid detection of pathogenic Vibrio spp. in aquatic organisms
    Xu, Hai-sheng
    He, Lin
    Lv, Sun-jian
    Gong, Qi
    Li, Song
    AFRICAN JOURNAL OF MICROBIOLOGY RESEARCH, 2012, 6 (14): : 3447 - 3454
  • [26] Development of a loop-mediated isothermal amplification (LAMP) assay for the sensitive detection of Haemonchus contortus eggs in ovine faecal samples
    Melville, Lynsey
    Kenyon, Fiona
    Javed, Sajid
    McElarney, Lain
    Demeler, Janina
    Skuce, Philip
    VETERINARY PARASITOLOGY, 2014, 206 (3-4) : 308 - 312
  • [27] Development and evaluation of a Loop Mediated Isothermal Amplification (LAMP) technique for the detection of hookworm (Necator americanus) infection in fecal samples
    Mugambi, Robert Muriuki
    Agola, Eric L.
    Mwangi, Ibrahim N.
    Kinyua, Johnson
    Shiraho, Esther Andia
    Mkoji, Gerald M.
    PARASITES & VECTORS, 2015, 8
  • [28] DEVELOPMENT AND EVALUATION OF A LOOP-MEDIATED ISOTHERMAL AMPLIFICATION (LAMP) ASSAY FOR THE DETECTION OF HAEMONCHUS CONTORTUS IN GOAT FECAL SAMPLES
    Yang, X.
    Qi, M. W.
    Zhang, Z. Z.
    Gao, C.
    Wang, C. Q.
    Lei, W. Q.
    Tan, L.
    Zhao, J. L.
    Fang, R.
    Hu, M.
    JOURNAL OF PARASITOLOGY, 2017, 103 (02) : 161 - 167
  • [29] "Shining a LAMP" (Loop-Mediated Isothermal Amplification) on the Molecular Detection of Phytopathogens Phytophthora spp. and Phytophthora cactorum in Strawberry Fields
    Siegieda, Dominika G.
    Panek, Jacek
    Frac, Magdalena
    PATHOGENS, 2021, 10 (11):
  • [30] Molecular detection of Brucella spp. in clinical samples of seropositive ruminants in Bosnia and Herzegovina
    Maksimovic, Zinka
    Jamakovic, Amela
    Semren, Orjana
    Rifatbegovic, Maid
    COMPARATIVE IMMUNOLOGY MICROBIOLOGY AND INFECTIOUS DISEASES, 2022, 86