Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis

被引:4
作者
Paterson, Andrew [1 ]
Franco, Vittorio [2 ]
Patel, Shanon [1 ]
Foschi, Federico [1 ,3 ]
机构
[1] Kings Coll London, Fac Dent Oral & Craniofacial Sci, Dept Endodont, London, England
[2] UKDS, St Alban, England
[3] IM Sechenov First Moscow State Med Univ, Inst Dent, Dept Therapeut Dent, Moscow, Russia
关键词
Tooth Apex; Cone-Beam Computed Tomography; Meta-Analysis; Dental Pulp Cavity; ELECTRONIC APEX LOCATOR; PART; 2; TEETH; RELIABILITY; ACCURACY; VALIDITY;
D O I
10.5624/isd.2020.50.3.183
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study was performed to assess the accuracy of preoperative cone-beam computed tomography (CBCT), when justified for other reasons, in locating the apical foramen and establishing the working length. Materials and Methods: Six electronic databases were searched for studies on this subject. All studies, of any type, were included if they compared measurements of working length with preoperative CBCT to measurements using an electronic apex locator (EAL) or histological reference standard. Due to the high levels of heterogeneity, an inverse-variance random-effects model was chosen, and weighted mean differences were obtained with 95% confidence intervals and P values. Results: Nine studies were included. Compared to a histological reference standard, CBCT indicated that the apical foramen was on average 0.40 mm coronal of its histological position, with a mean absolute difference of 0.48 mm. Comparisons were also performed to an EAL reference standard, but the conclusions could not be considered robust due to high levels of heterogeneity in the results. Conclusion: A low level of evidence is produced suggesting that preoperative CBCT shows the apical foramen to be on average 0.40 mm coronal to its histological position, with a mean absolute difference of 0.48 mm.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 43 条
  • [1] Effects of voxel size and resolution on the accuracy of endodontic length measurement using cone beam computed tomography
    Aktan, Ali Murat
    Yildirim, Cihan
    Karataslioglu, Emrah
    Ciftci, Mehmet Ertugrul
    Aksoy, Fatih
    [J]. ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2016, 208 : 96 - 102
  • [2] Aleksandraa D, 2019, SERBIAN DENT J, V66, P57
  • [3] Amin Janki, 2019, J Contemp Dent Pract, V20, P1118
  • [4] [Anonymous], 2004, EUR GUID RAD PROT DE
  • [5] Evaluation of Accuracy, Reliability, and Repeatability of Five Dental Pulp Tests
    Chen, Eugene
    Abbott, Paul V.
    [J]. JOURNAL OF ENDODONTICS, 2011, 37 (12) : 1619 - 1623
  • [6] Analysis of the apical constriction using micro-computed tomography and anatomical sections
    Citterio, Filippo
    Pellegatta, Alberto
    Citterio, Claudio Luigi
    Maddalone, Marcello
    [J]. GIORNALE ITALIANO DI ENDODONZIA, 2014, 28 (01): : 41 - 45
  • [7] Evaluation of the accuracy of nine electronic apex locators by using Micro-CT
    Connert, T.
    Judenhofer, M. S.
    Huelber-J, M.
    Schell, S.
    Mannheim, J. G.
    Pichler, B. J.
    Loest, C.
    ElAyouti, A.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (02) : 223 - 232
  • [8] Accuracy of endodontic working length determination using cone beam computed tomography
    Connert, T.
    Huelber-J, M.
    Godt, A.
    Loest, C.
    ElAyouti, A.
    [J]. INTERNATIONAL ENDODONTIC JOURNAL, 2014, 47 (07) : 698 - 703
  • [9] Davis RD, 2002, J ENDODONT, V28, P438
  • [10] de Morais Andre Luiz Gomide, 2016, Iran Endod J, V11, P164, DOI 10.7508/iej.2016.03.003