Determination of intrinsic viscosity of poly(ethylene terephthalate) using infrared spectroscopy and multivariate calibration method

被引:12
作者
Silva Spinace, M. A.
Lucato, M. U.
Ferrao, M. F.
Davanzo, C. U.
De Paoli, M. -A.
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13084971 Campinas, SP, Brazil
[2] Univ Santa Cruz do Sul, Dept Quim & Fis, BR-96815900 Santa Cruz do Rul, RS, Brazil
关键词
diffuse reflectance; intrinsic viscosity; poly(ethylene terephtalate); multivariate calibration; PET;
D O I
10.1016/j.talanta.2005.10.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
methodology was developed to determine the intrinsic viscosity of poly(ethylene terephthalate) (PET) using diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and multivariate calibration (MVC) methods. Multivariate partial least squares calibration was applied to the spectra using mean centering and cross validation. The results were correlated to the intrinsic viscosities determined by the standard chemical method (ASTM D 4603-01) and a very good correlation for values in the range from 0.346 to 0.780 dL g(-1) (relative viscosity values ca. 1.185-1.449) was observed. The spectrophotometer detector sensitivity and the humidity of the samples did not influence the results. The methodology developed is interesting because it does not produce hazardous wastes, avoids the use of time-consuming chemical methods and can rapidly predict the intrinsic viscosity of PET samples over a large range of values, which includes those of recycled materials. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:643 / 649
页数:7
相关论文
共 44 条
[1]   End-group determination in poly(ethylene terephthalate) by infrared spectroscopy [J].
Al-AbdulRazzak, S ;
Lofgren, EA ;
Jabarin, SA .
POLYMER INTERNATIONAL, 2002, 51 (02) :174-182
[2]  
*ASTM, 2001, D460301 ASTM
[3]   AN INTRODUCTION TO MULTIVARIATE CALIBRATION AND ANALYSIS [J].
BEEBE, KR ;
KOWALSKI, BR .
ANALYTICAL CHEMISTRY, 1987, 59 (17) :A1007-+
[4]   Validation of models of multivariate calibration: An application in the determination of polymorphic purity of carbamazepine by near infrared spectroscopy. [J].
Braga, JWB ;
Poppi, RJ .
QUIMICA NOVA, 2004, 27 (06) :1004-1011
[5]   Multiblock PLS as an approach to compare and combine NIR and MIR spectra in calibrations of soybean flour [J].
Brás, LP ;
Bernardino, SA ;
Lopes, JA ;
Menezes, JC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 75 (01) :91-99
[6]   Introduction to multivariate calibration in analytical chemistry [J].
Brereton, RG .
ANALYST, 2000, 125 (11) :2125-2154
[7]   FTIR, FT-Raman and chemometrics: Applications to the analysis and characterisation of polymers [J].
Chalmers, JM ;
Everall, NJ .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (01) :18-25
[8]   Vibrational spectroscopy: Instrumentation for infrared and Raman spectroscopy (Reprinted from Analytical Instrumentation Handbook, 1997) [J].
Coates, J .
APPLIED SPECTROSCOPY REVIEWS, 1998, 33 (04) :267-425
[9]   Density mapping in poly(ethylene terephthalate) using a fiber-coupled Raman microprobe and partial least-squares calibration [J].
Everall, N ;
Davis, K ;
Owen, H ;
Pelletier, MJ ;
Slater, J .
APPLIED SPECTROSCOPY, 1996, 50 (03) :388-393
[10]  
Faber K, 1997, J CHEMOMETR, V11, P419, DOI 10.1002/(SICI)1099-128X(199709/10)11:5<419::AID-CEM486>3.0.CO