Image quality improvement in three-dimensional time-of-flight magnetic resonance angiography using the subtraction method for brain and temporal bone diseases

被引:0
作者
Peng, Shu-Hui [1 ,2 ]
Shen, Chao-Yu [1 ,2 ,3 ]
Wu, Ming-Chi [1 ,2 ,3 ]
Lin, Yue-Der [4 ]
Huang, Chun-Huang [5 ]
Kang, Ruei-Jin [6 ]
Tyan, Yeu-Sheng [1 ,2 ,3 ]
Tsao, Teng-Fu [1 ,2 ,3 ,7 ]
机构
[1] Chung Shan Med Univ Hosp, Dept Med Imaging, Taichung 402, Taiwan
[2] Chung Shan Med Univ, Sch Med Imaging & Radiol Sci, Taichung, Taiwan
[3] Chung Shan Med Univ, Sch Med, Dept Radiol, Taichung, Taiwan
[4] Feng Chia Univ, Dept Automat Control Engn, Taichung 40724, Taiwan
[5] Chung Shan Med Univ, Inst Med, Taichung, Taiwan
[6] Natl Chi Nan Univ, Puli, Nantou, Taiwan
[7] Natl Chung Hsing Univ, Dept Vet Med, Taichung 40227, Taiwan
关键词
contamination; hematoma; magnetic resonance angiography; subtraction; MR-ANGIOGRAPHY; CONTRAST;
D O I
10.1016/j.jcma.2013.04.006
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Time-of-flight (TOF) magnetic resonance (MR) angiography is based on flow-related enhancement using the T1-weighted spoiled gradient echo, or the fast low-angle shot gradient echo sequence. However, materials with short T1 relaxation times may show hyperintensity signals and contaminate the TOF images. The objective of our study was to determine whether subtraction three-dimensional (3D) TOF MR angiography improves image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times. Methods: During the 12-month study period, patients who had masses with short T1 relaxation times noted on precontrast T1-weighted brain MR images and 24 healthy volunteers were scanned using conventional and subtraction 3D TOF MR angiography. The qualitative evaluation of each MR angiogram was based on signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and scores in three categories, namely, (1) presence of misregistration artifacts, (2) ability to display arterial anatomy selectively (without contamination by materials with short T1 relaxation times), and (3) arterial flow-related enhancement. Results: We included 12 patients with intracranial hematomas, brain tumors, or middle-ear cholesterol granulomas. Subtraction 3D TOF MR angiography yielded higher CNRs between the area of the basilar artery (BA) and normal-appearing parenchyma of the brain and lower SNRs in the area of the BA compared with the conventional technique (147.7 +/- 77.6 vs. 130.6 +/- 54.2, p < 0.003 and 162.5 +/- 79.9 vs. 194.3 +/- 62.3, p < 0.001, respectively) in all 36 cases. The 3D subtraction angiography did not deteriorate image quality with misregistration artifacts and showed a better selective display of arteries (p < 0.0001) and arterial flow-related enhancement (p < 0.044) than the conventional method. Conclusion: Subtraction 3D TOF MR angiography is more appropriate than the conventional method in improving the image quality in brain and temporal bone diseases with unwanted contaminations with short T1 relaxation times. Copyright (c) 2013 Elsevier Taiwan LLC and the Chinese Medical Association. All rights reserved.
引用
收藏
页码:458 / 465
页数:8
相关论文
共 16 条
[1]   T1 signal hyperintensity in the sellar region: Spectrum of findings [J].
Bonneville, Fabrice ;
Cattin, Francoise ;
Marsot-Dupuch, Kathlyn ;
Dormont, Didier ;
Bonneville, Jean-Francois ;
Chiras, Jacques .
RADIOGRAPHICS, 2006, 26 (01) :93-U171
[2]  
Campos A., 1996, Acta Oto-Rhino-Laryngologica Belgica, V50, P125
[3]   Three-dimensional time-of-flight subtraction angiography of subacute cerebral hemorrhage [J].
Chan, JHM ;
Peh, WCG ;
Tsui, EYK ;
Wong, KPC ;
Yuen, MK .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (01) :242-244
[4]   INTRACRANIAL MR-ANGIOGRAPHY - COMPARISON OF SINGLE-VOLUME 3-DIMENSIONAL TIME-OF-FLIGHT AND MULTIPLE OVERLAPPING THIN SLAB ACQUISITION TECHNIQUES [J].
DAVIS, WL ;
BLATTER, DD ;
HARNSBERGER, HR ;
PARKER, DL .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (04) :915-920
[5]   Quality assessment for CT colonography: Validation of automated measurement of colonic distention and residual fluid [J].
Deshpande, Keshav K. ;
Summers, Ronald M. ;
Van Uitert, Robert L. ;
Franaszek, Marek ;
Brown, Linda ;
Dwyer, Andrew J. ;
Fletcher, Joel G. ;
Choi, J. Richard ;
Pickhardt, Perry J. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 189 (06) :1457-1463
[6]   IMPROVED TIME-OF-FLIGHT MR ANGIOGRAPHY OF THE BRAIN WITH MAGNETIZATION TRANSFER CONTRAST [J].
EDELMAN, RR ;
AHN, SS ;
CHIEN, D ;
WEI, L ;
GOLDMANN, A ;
MANTELLO, M ;
KRAMER, J ;
KLEEFIELD, J .
RADIOLOGY, 1992, 184 (02) :395-399
[7]   A quantitative study of ramped radio frequency, magnetization transfer, and slab thickness in three-dimensional time-of-flight magnetic resonance angiography in a patient population [J].
Goodrich, KC ;
Blatter, DD ;
Parker, DL ;
Du, YPP ;
Meyer, KJ ;
Bernstein, MA .
INVESTIGATIVE RADIOLOGY, 1996, 31 (06) :323-332
[8]  
Handelsman H, 1994, Health Technol Assess (Rockv), P1
[9]   INTRACRANIAL VASCULAR STENOSIS AND OCCLUSION - EVALUATION WITH 3-DIMENSIONAL TIME-OF-FLIGHT MR ANGIOGRAPHY [J].
HEISERMAN, JE ;
DRAYER, BP ;
KELLER, PJ ;
FRAM, EK .
RADIOLOGY, 1992, 185 (03) :667-673
[10]   Magnetic Resonance Venography of Intracranial Venous Diseases [J].
Lirng, Jiing-Feng .
JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2010, 73 (06) :289-291