How reliable is MRCP with an SS-FSE sequence at 3.0 T: comparison between SS-FSE BH and 3D-FSE BH ASSET sequences

被引:4
|
作者
Lavdas, Eleftherios [1 ,2 ]
Vlychou, Marianna [1 ]
Arikidis, Nikolaos [1 ]
Kapsalaki, Eftychia [1 ]
Roka, Violeta [1 ]
Arvanitis, Dimitrios L. [3 ]
Fezoulidis, Ioannis [1 ]
Vassiou, Katerina [1 ,3 ]
机构
[1] Univ Hosp Larissa, Dept Radiol, Larisa, Greece
[2] Inst Athens, Dept Med Radiol Technol, Athens, Greece
[3] Univ Thessaly, Sch Hlth Sci, Dept Anat, Thessaly, Greece
关键词
Biliary system; Liver; 3.0; T; MRCP; Pancreatic system; Pancreatic-Biliary system; FAST SPIN-ECHO; PHASED-ARRAY COIL; CHOLANGIOPANCREATOGRAPHY; CHOLANGIOGRAPHY; ACQUISITION; RELAXATION; CHOLEDOCHOLITHIASIS; ENHANCEMENT; SENSE; DUCT;
D O I
10.1016/j.clinimag.2013.01.011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purpose of the present study was to evaluate the visibility and the image quality of the biliary and pancreatic duct system on magnetic resonance cholangiopancreatography (MRCP) images based on two breath-hold (BH) methods using array spatial sensitivity technique: a single-shot fast spin-echo (SS-FSE) sequence and a three-dimensional single slab fast spin-echo (3D-FSE) sequence. Materials and methods: In the present prospective comparative study, 47 patients (22 male and 25 female, mean age=50 years, age range=22-82 years) that were referred for MRCP during a 12-month period are included. All of them were referred with suspected pancreaticobiliary disease. All patients underwent MRCP with both a SS-FSE BH sequence and a 3D-FSE BH sequence. Qualitative evaluation regarding the depiction of three segments of the pancreaticobiliary tree and the frequency of artifacts was performed. Two radiologists graded each sequence of the obtained studies in a blinded fashion. Quantitative evaluation including calculation of relative signal intensity (rSI) and relative contrast (RC) ratios at seven segments of the pancreaticobiliary tree between fluid-filled ductal structures and organ parenchyma at the same ductal segments was performed. In order to evaluate the parameters' differences of the two sequences, either in qualitative or in quantitative analysis, the Wilcoxon paired signed-rank test was performed. Results: On quantitative evaluation, both rSI and RC ratios of all segments of the pancreaticobiliary tree at SS-FSE BH sequence were higher than those at 3D-FSE BH sequences. This finding was statistically significant (P<.01). On qualitative evaluation, the two radiologists found intrahepatic ducts and pancreatic ducts to be better visualized with SS-FSE BH than with 3D-FSE BH sequence. This finding was statistically significant (P<.02). One of them found extrahepatic ducts to be significantly better visualized with SS-FSE BH sequence. Moreover, the frequency of artifacts was lower in the SS-FSE sequence, a finding that was of statistical significance. Interobserver agreement analysis found at least substantial agreement (kappa>0.60) between the two radiologists. Conclusion: The SS-FSE sequence is performed faster and significantly improves image quality; thus, it should be included into the routine MRCP sequence protocol at 3.0 T. Furthermore, we recommended SS-FSE BH MRCP examination to be applied to uncooperative patients or patients in emergency because of its short acquisition time (1 s). (c) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:697 / 703
页数:7
相关论文
共 7 条
  • [1] MR imaging of brain: Comparison between SS-FSE and fast spin-echo T2-weighted pulse sequences
    Seo, JJ
    Kang, HK
    Jeong, GW
    Jeong, YY
    Kim, JK
    Park, JG
    Chung, TW
    Kim, YH
    RIVISTA DI NEURORADIOLOGIA, 1998, 11 : 125 - 129
  • [2] Bowel obstruction in pregnancy: value of Single Shot Fast Spin Echo MR sequence (SS-FSE)
    Juglard, R
    Rimbot, A
    Marty, A
    Paoletti, H
    Aczel, F
    Talarmin, B
    Arteaga, C
    JOURNAL DE RADIOLOGIE, 2003, 84 (12): : 1986 - 1988
  • [3] MR imaging of articular cartilage at 1.5T and 3.0T: comparison of IDEAL 2D FSE and 3D SPGR with fat-saturated 2D FSE and 3D SPGR in a porcine model
    Cha, Jang Gyu
    Yoo, Jae Ho
    Rhee, Sun Jung
    Hwang, Seung Sik
    Han, Jong Kyu
    ACTA RADIOLOGICA, 2014, 55 (04) : 462 - 469
  • [4] Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
    Shingo Kakeda
    Yukunori Korogi
    Yasuhiro Hiai
    Norihiro Ohnari
    Junji Moriya
    Koji Kamada
    Mai Hanamiya
    Toru Sato
    Mika Kitajima
    European Radiology, 2007, 17 : 2345 - 2351
  • [5] Detection of brain metastasis at 3T: comparison among SE, IR-FSE and 3D-GRE sequences
    Kakeda, Shingo
    Korogi, Yukunori
    Hiai, Yasuhiro
    Ohnari, Norihiro
    Moriya, Junji
    Kamada, Koji
    Hanamiya, Mai
    Sato, Toru
    Kitajima, Mika
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2345 - 2351
  • [6] Comparison of FSE T2W and 3D FIESTA sequences in the evaluation of posterior fossa cranial nerves with MR cisternography
    Hatipoglu, Hatice Guel
    Durakoglugil, Tugba
    Ciliz, Deniz
    Yueksel, Enis
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2007, 13 (02): : 56 - 60
  • [7] Comparison between 2D FSE T2-weighted Dixon MRI and contrast-enhanced 2D FSE and 3D FSPGR T1-weighted Dixon MRI to quantify inflammation in hands of patients with early rheumatoid arthritis
    Dion, Brice
    Lacrosse, Romain
    Michoux, Nicolas
    Stoenoiu, Maria
    Durez, Patrick
    Lecouvet, Frederic
    Kirchgesner, Thomas
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2023, 104 (7-8) : 351 - 358