Conductometric determination of ammonium by a multisyringe flow injection system applying gas diffusion

被引:13
作者
Henriquez, Camelia [1 ]
Horstkotte, Burkhard [2 ]
Cerda, Victor [1 ]
机构
[1] Univ Balearic Isl, Dept Chem, Palma De Mallorca 07122, Spain
[2] Mediterranean Inst Adv Studies, Dept Global Change Res, Esporles 07190, Spain
关键词
ammonium; multisyringe flow injection analysis; gas diffusion; conductometric detection; natural waters; SEQUENTIAL INJECTION; IN-SITU; PART I; SEPARATION; ANALYZER; WATERS; CARBON; ION;
D O I
10.1080/03067319.2012.746322
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multisyringe flow injection system (MSFIA) coupled to a gas-diffusion cell has been developed for the conductometric determination of ammonium in different water samples. Operation strategies, membrane, reagent concentrations, and flow rates have been studied to optimize the sensitivity of detection and to fit the required working range. The proposed MSFIA system has been compared with former FIA and SIA systems using gas diffusion. The system was applied to the determination of ammonium in water samples of different matrices in order to evaluate its performance. These samples were coastal waters, pond waters, and compost aqueous extracts. Good recoveries of 102 +/- 13% were obtained and no significant differences with the reference methods were found. The system can be used for a wide concentration range of ammonia, from 0.075 to 360mgL(-1), without sample dilution and with a precision better than 2% of RSD. The throughput of the method was 32 injections per hour.
引用
收藏
页码:1236 / 1252
页数:17
相关论文
共 33 条
[1]   A robust multisyringe system for process flow analysis -: Part I.: On-line dilution and single point titration of protolytes [J].
Albertús, F ;
Horstkotte, B ;
Cladera, A ;
Cerdá, V .
ANALYST, 1999, 124 (09) :1373-1381
[2]   A membraneless gas-diffusion unit - multisyringe flow injection spectrophotometric method for ammonium determination in untreated environmental samples [J].
Almeida, M. Ines G. S. ;
Manuel Estela, Jose ;
Segundo, Marcela A. ;
Cerda, Victor .
TALANTA, 2011, 84 (05) :1244-1252
[3]   A flow injection-fluorometric method for the determination of ammonium in fresh and saline waters with a view to in situ analyses [J].
Aminot, A ;
Kérouel, R ;
Birot, D .
WATER RESEARCH, 2001, 35 (07) :1777-1785
[4]   Airborne reduced nitrogen: ammonia emissions from agriculture and other sources [J].
Anderson, N ;
Strader, R ;
Davidson, C .
ENVIRONMENT INTERNATIONAL, 2003, 29 (2-3) :277-286
[5]  
APHA-AWWA-WPCF, 1992, MET NORM AN AG POT R
[6]   Lab on valve-multisyringe flow injection system (LOV-MSFIA) for fully automated uranium determination in environmental samples [J].
Avivar, Jessica ;
Ferrer, Laura ;
Casas, Montserrat ;
Cercia, Victor .
TALANTA, 2011, 84 (05) :1221-1227
[7]   Trace Levels Determination of Ammonium by Flow Injection Analysis Using Gas-Diffusion and Capacitively Coupled Contactless Conductivity Detection [J].
Braz, Henrique L. ;
Ito, Debora T. ;
Fracassi da Silva, Jose A. ;
do Lago, Claudimir L. ;
Pedrotti, Jairo J. .
ELECTROANALYSIS, 2011, 23 (11) :2594-2600
[8]  
Capone DG, 2008, NITROGEN IN THE MARINE ENVIRONMENT, 2ND EDITION, P1, DOI 10.1057/9780230226203.3567
[9]   EVALUATION OF FLOW-INJECTION METHODS FOR AMMONIUM DETERMINATION IN WASTE-WATER SAMPLES [J].
CERDA, A ;
OMS, MT ;
FORTEZA, R ;
CERDA, V .
ANALYTICA CHIMICA ACTA, 1995, 311 (02) :165-173
[10]   Flow techniques in water analysis [J].
Cerdà, V ;
Estela, JM ;
Forteza, R ;
Cladera, A ;
Becerra, E ;
Altimira, P ;
Sitjar, P .
TALANTA, 1999, 50 (04) :695-705