Reduced-scale experimental and numerical study of fire in a hybrid ventilation system in a large underground subway depot with superstructures under fire scenario

被引:20
作者
Wang, Zhilei [1 ]
Zhu, Li [1 ]
Guo, Xinxin [1 ]
Pan, Xuhai [1 ,2 ,3 ]
Zhou, Bin [4 ]
Yang, Juan [1 ]
Jiang, Juncheng [1 ,2 ,3 ]
Hua, Min [1 ,3 ]
Feng, Lu [4 ]
机构
[1] Nanjing Tech Univ, Coll Safety Sci & Engn, Nanjing 210009, Jiangsu, Peoples R China
[2] Nanjing Tech Univ, Inst Fire Sci & Engn, Nanjing 210009, Jiangsu, Peoples R China
[3] Nanjing Tech Univ, Jiangsu Key Lab Urban & Ind Safety, Nanjing 210009, Jiangsu, Peoples R China
[4] Nanjing Tech Univ, Coll Urban Construct, Nanjing 210009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
Underground large space; Superstructure; Hybrid ventilation; Scaling model; Smoke control; NATURAL VENTILATION; SMOKE MOVEMENT; TUNNEL; PERFORMANCE; SIMULATION; EMERGENCY; SPREAD; SHAFT; MODE; FLOW;
D O I
10.1016/j.tust.2019.02.006
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To reduce energy consumption and improve the safety and reliability of ventilation systems in underground subway depots, a hybrid ventilation (HV) system composed of natural ventilation, mechanical fans, and flow deflectors was proposed and tested. A reduced-scale (1:50) experiment and a full-scale numerical simulation were conducted, wherein four heat release rates (HRRs; 281 W, 380 W, 531 W, and 866 W) of the fire source and five ventilation velocities (0.7 m/s, 1.0 m/s, 1.4 m/s, 1.9 m/s, and 2.4 m/s) were tested. The temperature distributions under the ceiling were measured. Smoke movement and smoke layer stability were visualized using a laser sheet. The smoke layer height, gas flux of shafts, and smoke movement route were recorded from the simulation. Under HV, the ceiling temperature decreased significantly with increasing ventilation velocity; however, changes in temperature were different at different locations. With appropriate ventilation velocity (1.4 m/s), HV effectively controlled the smoke temperature of the bottom layer and ensured the stability of the smoke layer in the interlayer. However, the stability of the smoke layer was disrupted at higher ventilation velocities, which caused the smoke to sink, whereas a lower velocity could not slow the rise in temperature. The relationship among ventilation velocity, HRR, ceiling temperature, and smoke layer stability was analysed. A new criterion, N (N = 0.62), was proposed to determine the critical ventilation velocity associated with a lower ceiling temperature and improved smoke layer stability.
引用
收藏
页码:98 / 112
页数:15
相关论文
共 34 条
[1]  
[Anonymous], 92B NFPA
[2]  
[Anonymous], 1991, GEN ROUTING ANAL STA
[3]  
Awbi H.B., 2003, Ventilation of Buildings, V2nd
[4]  
Chen F, 2003, THEOR COMP FLUID DYN, V16, P349, DOI [10.1007/s00162-002-0086-5, 10.1007/S00162-002-0086-5]
[5]   Vertical temperature distributions in ventilation shafts during a fire [J].
Chen, Yanqiu ;
Zhou, Xiaodong ;
Fu, Zhijian ;
Zhang, Taolin ;
Cao, Bei ;
Yang, Lizhong .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2016, 79 :118-125
[6]   Scale modeling studies on stack effect in tall vertical shafts [J].
Chow, W. K. ;
Zhao, J. H. .
JOURNAL OF FIRE SCIENCES, 2011, 29 (06) :531-542
[7]   Prediction of the spread of smoke in a huge transit terminal subway station under six different fire scenarios [J].
Gao, Ran ;
Li, Angui ;
Hao, Xinpeng ;
Lei, Wenjun ;
Deng, Baoshun .
TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2012, 31 :128-138
[8]   Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station [J].
Gao, Ran ;
Li, Angui ;
Hao, Xinpeng ;
Lei, Wenjun ;
Zhao, Yujiao ;
Deng, Baoshun .
ENERGY AND BUILDINGS, 2012, 45 :280-289
[9]   Smoke spreading analysis from an experimental subway scale model [J].
Giachetti, B. ;
Couton, D. ;
Plourde, F. .
FIRE SAFETY JOURNAL, 2016, 86 :75-82
[10]   Large Eddy Simulation of stack effect on natural smoke exhausting effect in urban road tunnel fires [J].
Ji, J. ;
Gao, Z. H. ;
Fan, C. G. ;
Sun, J. H. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2013, 66 :531-542