Out-of-Step Protection Using Equal Area Criterion in Time Domain

被引:0
|
作者
Sauhats, Antans [1 ]
Utans, Andrejs [1 ]
Antonovs, Dmitrijs [1 ]
Biela-Dalidovicha, Edite [1 ]
机构
[1] Riga Tech Univ, Inst Power Engn, Riga, Latvia
来源
2016 57TH INTERNATIONAL SCIENTIFIC CONFERENCE ON POWER AND ELECTRICAL ENGINEERING OF RIGA TECHNICAL UNIVERSITY (RTUCON) | 2016年
关键词
angular instability; out-of-step protection; equal area criterion in time domain; wide-area measurements; SLOW COHERENCY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes the out-of-step (OOS) protection system, which operation principle is based on combination of two approaches: equal area criterion, implemented in time domain, is used for generators first swing stability assessment and generation sources electromotive forces (emf) vectors angle control is used for multi swing instability detection. The paper focuses on possibilities of practical implementation of the above mentioned approaches within real time operating OOS protection system. Protection system structure and principles of operation addressed in the paper.
引用
收藏
页数:6
相关论文
共 27 条
  • [21] Out-of-step protection of generator using analysis of angular velocity and acceleration data measured from magnetic flux
    Yaghobi, Hamid
    ELECTRIC POWER SYSTEMS RESEARCH, 2016, 132 : 9 - 21
  • [22] Angle Control-Based Multi-Terminal Out-of-Step Protection System
    Sauhats, Antans
    Utans, Andrejs
    Antonovs, Dmitrijs
    Svalovs, Andrejs
    ENERGIES, 2017, 10 (03):
  • [23] A novel approach for out-of-step protection based on Clarke's transformation and analytic geometry parameters
    Ramon Camarillo-Penaranda, Juan
    Celeita, David
    Gutierrez, Mario
    Toro, Mateo
    Ramos, Gustavo A.
    2019 IEEE INDUSTRY APPLICATIONS SOCIETY ANNUAL MEETING, 2019,
  • [24] Online Detection of Out-of-Step Condition Using PMU-Determined System Impedances
    Tealane, Marko
    Kilter, Jako
    Popov, Marjan
    Bagleybter, Oleg
    Klaar, Danny
    IEEE ACCESS, 2022, 10 : 14807 - 14818
  • [25] A Predictive Generator Out-of-Step Protection and Transient Stability Monitoring Scheme Enabled by a Distributed Dynamic State Estimator
    Farantatos, Evangelos
    Huang, Renke
    Cokkinides, George J.
    Meliopoulos, A. P.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2016, 31 (04) : 1826 - 1835
  • [26] OUT-OF-STEP protection in rotating generation networks for hydrogen fuel production. Modeling conditions to test its algorithms☆
    Osintsev, Anatoliy A.
    Frolova, Ekaterina I.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 91 : 574 - 583
  • [27] Performance evaluation of impedance-based synchronous generator out-of-step protection in the presence of unified power flow controller
    Hosseini, Seyed Rasoul
    Karrari, Mehdi
    Abyaneh, Hossein Askarian
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 114