A Methodology for the Direct Assessment of the Damping Ratio of Structures Equipped with Nonlinear Viscous Dampers

被引:53
作者
Diotallevi, Pier Paolo [1 ]
Landi, Luca [1 ]
Dellavalle, Alberto [1 ]
机构
[1] Univ Bologna, Dept Civil Environm & Mat Engn DICAM, I-40136 Bologna, Italy
关键词
Nonlinear Viscous Dampers; Equivalent Damping Ratio; Damper Index; Design Spectra; Design Procedure; MODAL-ANALYSIS PROCEDURES; EQUIVALENT LATERAL FORCE; FRAMED STRUCTURES; SEISMIC RESPONSE; DESIGN; BUILDINGS; PLACEMENT; 2000-NEHRP-PROVISIONS; RETROFIT;
D O I
10.1080/13632469.2011.618521
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The expressions proposed in literature for the supplemental damping ratio provided by nonlinear viscous dampers usually include a term related to the structural response, so that iterative procedures are required. This article proposes a simplified method for the direct assessment of the supplemental damping ratio on the basis of a new dimensionless parameter, called damper index. The methodology has been verified through numerical investigations, considering single- and multi-degree of freedom systems subjected to harmonic excitations and ground motions. A procedure is also proposed for obtaining design spectra of the damping ratio in terms of the damper index.
引用
收藏
页码:350 / 373
页数:24
相关论文
共 44 条
[1]  
Agrawal AK, 1999, J INTEL MAT SYST STR, V10, P997, DOI 10.1106/YV3B-TP5H-HWQ2-X10K
[2]  
[Anonymous], P 12 EUR C EARTHQ EN
[3]  
[Anonymous], 2003, EUR 8 DES STRUCT E 1
[4]  
[Anonymous], MONOGRAPH STATE U NE
[5]  
[Anonymous], ENG STRUCTURES
[6]  
Building Seismic Safety Council (BSSC), 2003, Rept. No. FEMA 450
[7]  
Chopra AnilK., 2000, Earthquake Spectra, V23, DOI DOI 10.1193/1.1586188
[8]  
Christopoulos C., 2006, Principles of Passive Supplemental Damping and Seismic Isolation
[9]  
Constantinou M.C., 1992, Experimental and analytical investigation of seismic response of structures with supplemental fluid viscous dampers
[10]  
Constantinou M.C., 1993, STRUCT DES TALL BUIL, V2, P77