摘要
Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant:. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UK-A and TKA unproved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery. (C) 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:202-207, 2009
引用
收藏
页码:202 / 207
页数:6
相关论文
共 36 条
[11]   The Rolimeter: a new arthrometer compared with the KT-1000 [J].
Ganko, A ;
Engebretsen, L ;
Ozer, H .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2000, 8 (01) :36-39
[12]   A JOINT COORDINATE SYSTEM FOR THE CLINICAL DESCRIPTION OF 3-DIMENSIONAL MOTIONS - APPLICATION TO THE KNEE [J].
GROOD, ES ;
SUNTAY, WJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1983, 105 (02) :136-144
[13]   Three-dimensional determination of femoral-tibial contact positions under in vivo conditions using fluoroscopy [J].
Hoff, WA ;
Komistek, RD ;
Dennis, DA ;
Gabriel, SM ;
Walker, SA .
CLINICAL BIOMECHANICS, 1998, 13 (07) :455-472
[14]   Tibiofemoral movement 1: the shapes and relative movements of the femur and tibia in the unloaded cadaver knee [J].
Iwaki, H ;
Pinskerova, V ;
Freeman, MAR .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1189-1195
[15]  
Jenny Jean-Yves, 2008, Instr Course Lect, V57, P721
[16]   Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation [J].
Jenny, JY ;
Boeri, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2003, 11 (01) :40-45
[17]   The effect of tibial polyethylene insert design on range of motion - Evaluation of in vivo knee kinematics by a computerized navigation system during total knee arthroplasty [J].
Klein, GR ;
Parvizi, J ;
Rapuri, VR ;
Austin, MS ;
Hozack, WJ .
JOURNAL OF ARTHROPLASTY, 2004, 19 (08) :986-991
[18]  
Krackow KA, 1999, ORTHOPEDICS, V22, P698
[19]   Knee kinematics with a high-flexion posterior stabilized total knee prosthesis: An in vitro robotic experimental investigation [J].
Li, G ;
Most, E ;
Sultan, PG ;
Schule, S ;
Zayontz, S ;
Park, SE ;
Rubash, HE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2004, 86A (08) :1721-1729
[20]   KIN-Nav navigation system for kinematic assessment in anterior cruciate ligament reconstruction: features, use, and perspectives [J].
Martelli, S. ;
Zaffagnini, S. ;
Bignozzi, S. ;
Lopomo, N. F. ;
Iacono, F. ;
Marcacci, M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2007, 221 (H7) :725-737