Knee Stability before and after Total and Unicondylar Knee Replacement: In Vivo Kinematic Evaluation Utilizing Navigation

被引:25
作者
Casino, Daniela [1 ]
Martelli, Sandra [1 ]
Zaffagnini, Stefano [1 ]
Lopomo, Nicola [1 ]
Iacono, Francesco [1 ]
Bignozzi, Simone [1 ]
Visani, Andrea [1 ]
Marcacci, Maurilio [1 ]
机构
[1] Ist Ortoped Rizzoli, Lab Biomeccan, I-40136 Bologna, Italy
关键词
computer-assisted surgery; knee replacement; screw-home; screw-home mechanism; knee kinematics; MOBILE-BEARING; OSTEOARTHRITIC KNEES; ACL RECONSTRUCTION; FIXED-BEARING; ARTHROPLASTY; SYSTEM; IMPLANTATION; PROSTHESIS; VALIDATION; ALIGNMENT;
D O I
10.1002/jor.20746
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Surgical navigation systems are currently used to guide the surgeon in the correct alignment of the implant:. The aim of this study was to expand the use of navigation systems by proposing a surgical protocol for intraoperative kinematics evaluations during knee arthroplasty. The protocol was evaluated on 20 patients, half undergoing unicondylar knee arthroplasty (UKA) and half undergoing posterior-substituting, rotating-platform total knee arthroplasty (TKA). The protocol includes a simple acquisition procedure and an original elaboration methodology. Kinematic tests were performed before and after surgery and included varus/valgus stress at 0 and 30 degrees and passive range of motion. Both UK-A and TKA unproved varus/valgus stability in extension and preserved the total magnitude of screw-home motion during flexion. Moreover, compared to preoperative conditions, values assumed by tibial axial rotation during flexion in TKA knees were more similar to the rotating patterns of UKA knees. The analysis of the anteroposterior displacement of the knee compartments confirmed that the two prostheses did not produce medial pivoting, but achieved a postoperative normal behavior. These results demonstrated that proposed intraoperative kinematics evaluations by a navigation system provided new information on the functional outcome of the reconstruction useful to restore knee kinematics during surgery. (C) 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:202-207, 2009
引用
收藏
页码:202 / 207
页数:6
相关论文
共 36 条
[1]   In vivo kinematics of cruciate-retaining and -substituting knee arthroplasties [J].
Banks, SA ;
Markovich, GD ;
Hodge, WA .
JOURNAL OF ARTHROPLASTY, 1997, 12 (03) :297-304
[2]   Reliability of the KT-1000 arthrometer (Medmetric) for measuring anterior knee laxity: comparison with Telos in 147 knees [J].
Boyer, P ;
Djian, R ;
Christel, R ;
Paoletti, X ;
Degeorges, R .
REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2004, 90 (08) :757-764
[3]  
Buckup K, 2007, ORTHOPEDICS, V30, P66
[4]  
COLWELL CW, 2004, J BONE JOINT SURG S3, V87, P342
[5]  
CROMIE MJ, 2008, J ORTHOP RES
[6]  
Delp SL, 1998, CLIN ORTHOP RELAT R, P49
[7]  
Delport HP, 2006, J BONE JOINT SURG BR, V88B, P1016, DOI 10.1302/0301-620X.88B8
[8]   In vivo determination of normal and anterior cruciate ligament-deficient knee kinematics [J].
Dennis, DA ;
Mahfouz, MR ;
Komistek, RD ;
Hoff, W .
JOURNAL OF BIOMECHANICS, 2005, 38 (02) :241-253
[9]  
Dennis DA, 1996, CLIN ORTHOP RELAT R, P107
[10]   Alignments and clinical results in conventional and navigated total knee arthroplasty [J].
Ensini, A. ;
Catani, F. ;
Leardini, A. ;
Romagnoli, M. ;
Giannini, S. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (457) :156-162