Equipment failure rate updating-Bayesian estimation

被引:18
作者
Shafaghi, Ahmad [1 ]
机构
[1] ABS Consulting, Houston, TX 77060 USA
关键词
Bayes' theorem; Failure rate; Prior distribution; Posterior distribution; Poisson distribution; Gamma distribution; Conjugate gamma distribution;
D O I
10.1016/j.jhazmat.2008.01.042
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The paper presents a Bayes' method for augmenting generic equipment failure data with a prior distribution - predicated on the evidence, e.g., plant data - resulting in a posterior distribution. The depth of the evidence is significant in shaping the characteristics of the posterior distribution. In conditions of insufficient data about the prior distribution or great uncertainty in the generic data sources, we may use "constrained non-informative priors". This representation of the prior preserves the mean value of the failure rate estimate and maintains a broad uncertainty range to accommodate the site-specific event data. Although the methodology and the case study presented in this paper focus on the calculation of a time-based (i.e., failures per unit time) failure rate, based on a Poisson likelihood function and the conjugate gamma distribution, a similar method applies to the calculation of demand failure rates utilizing the binomial likelihood function and its conjugate beta distribution. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:87 / 91
页数:5
相关论文
共 17 条
  • [1] [Anonymous], PROBABILITY THEORY L
  • [2] [Anonymous], 2002, Offshore reliability data handbook
  • [3] Atwood C., 2003, NUREGCR6823
  • [4] ATWOOD CL, 1994, CONSTRAINED NONINFOR
  • [5] BLANTON CH, 1993, WSSRCTR93262
  • [6] BUSH SH, 1988, J PRESS VESS TEC AUG
  • [7] Center for Chemical Process Safety, 1989, GUID PROC EQ REL DAT
  • [8] *CTR CHEM PROC SAF, 1985, GUID CHEM PROC QUANT
  • [9] *IEEE, 1993, 5001984IEEE