Light Transmission in the Human Cornea as a Function of Position across the Ocular Surface: Theoretical and Experimental Aspects

被引:53
作者
Doutch, James [1 ]
Quantock, Andrew J. [1 ]
Smith, Valerie A. [2 ]
Meek, Keith M. [1 ]
机构
[1] Cardiff Univ, Sch Optometry & Vis Sci, Struct Biophys Grp, Cardiff, S Glam, Wales
[2] Univ Bristol, Bristol Eye Hosp, Acad Surg Ophthalmol, Bristol, Avon, England
基金
英国医学研究理事会;
关键词
D O I
10.1529/biophysj.108.132316
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This article investigates the theoretical basis for differences in visible light transmission through the human cornea as a function of distance from the center. Experimentally, transmission decreases approximately linearly up to 3 mm from the central axis, then quadratically beyond this. It is known that collagen fibril number density and collagen fibril radii change from the central region to the corneal periphery. We modeled, using the direct-summation-of-scattered-fields method, the effects these ultrastructural changes would be expected to have on light transmission, accounting for the increase in corneal thickness from center to edge. Fibril positions for the modeling were obtained from electron micrographs of human cornea. Theoretically, transmission remains fairly constant across the central cornea; then, as the fibril diameter increases, the predicted scattering increases. Interfibrillar spacing changes alter the refractive index ratio between matrix and fibril; this was modeled in our theoretical deductions. Fibril number density had a minimal effect on light propagation. Our theoretical deductions were in broad agreement with our experimental data. It is concluded that the reduced transparency in the peripheral stroma is primarily caused by changes in fibril radius and an increase in refractive index ratio between the fibril and the interfibrillar substance.
引用
收藏
页码:5092 / 5099
页数:8
相关论文
共 54 条
[1]   X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus [J].
Aghamohammadzadeh, H ;
Newton, RH ;
Meek, KM .
STRUCTURE, 2004, 12 (02) :249-256
[2]   LIGHT TRANSMISSION OF THE CORNEA IN WHOLE HUMAN EYES [J].
BEEMS, EM ;
VANBEST, JA .
EXPERIMENTAL EYE RESEARCH, 1990, 50 (04) :393-395
[3]   THEORY OF TRANSPARENCY OF EYE [J].
BENEDEK, GB .
APPLIED OPTICS, 1971, 10 (03) :459-&
[4]  
Bergmanson Jan P G, 2005, Eye Contact Lens, V31, P281, DOI 10.1097/01.ICL.0000165280.94927.0D
[5]  
BEST JAV, 1988, EXP EYE RES, V46, P765
[6]   Collagen fibrils appear more closely packed in the prepupillary cornea: Optical and biomechanical implications [J].
Boote, C ;
Dennis, S ;
Newton, RH ;
Puri, H ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (07) :2941-2948
[7]   PROTEOGLYCANS AND COLLAGEN FIBER ORGANIZATION IN HUMAN CORNEOSCLERAL TISSUE [J].
BORCHERDING, MS ;
BLACIK, LJ ;
SITTIG, RA ;
BIZZELL, JW ;
BREEN, M ;
WEINSTEIN, HG .
EXPERIMENTAL EYE RESEARCH, 1975, 21 (01) :59-70
[8]   Spatial mapping of polarized light transmission in the central rabbit cornea [J].
ChristensBarry, WA ;
Green, WJ ;
Connolly, PJ ;
Farrell, RA ;
McCally, RL .
EXPERIMENTAL EYE RESEARCH, 1996, 62 (06) :651-662
[9]  
Connon CJ, 2003, J REFRACT SURG, V19, P323
[10]   TRANSPARENCY OF MAMMALIAN CORNEA [J].
COX, JL ;
FARRELL, RA ;
HART, RW ;
LANGHAM, ME .
JOURNAL OF PHYSIOLOGY-LONDON, 1970, 210 (03) :601-&