Epileptic Seizure Detection Using Lacunarity and Bayesian Linear Discriminant Analysis in Intracranial EEG

被引:107
作者
Zhou, Weidong [1 ]
Liu, Yinxia [1 ]
Yuan, Qi [1 ]
Li, Xueli [1 ]
机构
[1] Shandong Univ, Sch Informat Sci & Engn, Jinan 250100, Peoples R China
关键词
Bayesian linear discriminant analysis (BLDA); lacunarity; seizure detection; wavelet transform; NEURAL-NETWORK; SYSTEM; LONG; RECOGNITION; ONSET;
D O I
10.1109/TBME.2013.2254486
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Automatic seizure detection plays an important role in long-term epilepsy monitoring, and seizure detection algorithms have been intensively investigated over the years. This paper proposes an algorithm for seizure detection using lacunarity and Bayesian linear discriminant analysis (BLDA) in long-term intracranial EEG. Lacunarity is a measure of heterogeneity for a fractal. The proposed method first conducts wavelet decomposition on EEGs with five scales, and selects the wavelet coefficients at scale 3, 4, and 5 for subsequent processing. Effective features including lacunarity and fluctuation index are extracted from the selected three scales, and then sent into the BLDA for training and classification. Finally, postprocessing which includes smoothing, threshold judgment, multichannels integration, and collar technique is applied to obtain high sensitivity and low false detection rate. The proposed algorithm is evaluated on 289.14 h intracranial EEG data from 21-patient Freiburg dataset and yields a sensitivity of 96.25% and a false detection rate of 0.13/h with a mean delay time of 13.8 s.
引用
收藏
页码:3375 / 3381
页数:7
相关论文
共 33 条
  • [1] A fuzzy rule-based system for epileptic seizure detection in intracranial EEG
    Aarabi, A.
    Fazel-Rezai, R.
    Aghakhani, Y.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2009, 120 (09) : 1648 - 1657
  • [2] Analysis of EEG records in an epileptic patient using wavelet transform
    Adeli, H
    Zhou, Z
    Dadmehr, N
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2003, 123 (01) : 69 - 87
  • [3] [Anonymous], 1983, FRACTAL GEOMETRY NAT
  • [4] [Anonymous], 2008, FREIBURG SEIZURE PRE
  • [5] [Anonymous], 2007, EEG SIGNAL PROCESSIN, DOI DOI 10.1002/9780470511923
  • [6] Validation of a new automated neonatal seizure detection system: A clinician's perspective
    Cherian, P. J.
    Deburchgraeve, W.
    Swarte, R. M.
    De Vos, M.
    Govaert, P.
    Van Huffel, S.
    Visser, G. H.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2011, 122 (08) : 1490 - 1499
  • [7] Improved patient specific seizure detection during pre-surgical evaluation
    Chua, Eric C. -P.
    Patel, Kunjan
    Fitzsimons, Mary
    Bleakley, Chris J.
    [J]. CLINICAL NEUROPHYSIOLOGY, 2011, 122 (04) : 672 - 679
  • [8] Fractal signature and lacunarity in the measurement of the texture of trabecular bone in clinical CT images
    Dougherty, G
    Henebry, GM
    [J]. MEDICAL ENGINEERING & PHYSICS, 2001, 23 (06) : 369 - 380
  • [9] Seizure detection using a self-organizing neural network: validation and comparison with other detection strategies
    Gabor, AJ
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 107 (01): : 27 - 32
  • [10] AUTOMATIC RECOGNITION AND QUANTIFICATION OF INTERICTAL EPILEPTIC ACTIVITY IN HUMAN SCALP EEG
    GOTMAN, J
    GLOOR, P
    [J]. ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1976, 41 (05): : 513 - 529