Investigation on RF Connector Degradation Using Time Domain Reflectometry

被引:0
作者
Li, Qingya [1 ]
Ji, Rui [1 ]
Gao, Jinchun [1 ]
Flowers, George T. [3 ]
Xie, Gang [2 ]
Ye, Weibin [4 ]
机构
[1] Beijing Univ Posts & Telecommun, Sch Elect Engn, Beijing 100876, Peoples R China
[2] Beijing Univ Posts & Telecommun, Sch Informat & Commun Engn, Beijing 100876, Peoples R China
[3] Auburn Univ, Ctr Adv Vehicle & Extreme Environm Elect CAVE3, Auburn, AL 36849 USA
[4] Keysight Technol China Co Ltd, Beijing 100102, Peoples R China
来源
2017 63RD IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS | 2017年
关键词
Time Domain Reflectometry (TDR); Radio Frequency (RF) connector; contact failure; degradation; CONSTRICTION RESISTANCE;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radio Frequency (RF) connectors play an important part in electronic and communication systems. They are generally subjected to degradation in the contact interface during their service life, which affects signal integrity and communication quality of the systems. In the present work, the characteristics of RF connector degradation were theoretically analyzed and experimentally investigated using Time Domain Reflectometry (TDR). An accelerated test was designed to obtain the degraded connector samples. A series of experiments were conducted to measure the reflected voltages using a Network Analyzer for time domain analysis. Then, the reflection coefficients and load impedance were determined and the location of the degraded contact interface was identified. Based on classical electrical contact theory, transmission lines theory, and experimental results, an equivalent circuit model was developed and the degradation mechanism analyzed. The results showed that inductive characteristics increase with increase of the degradation. As the degradation increases beyond a certain level, the connector exhibits a more capacitive characteristic.
引用
收藏
页码:152 / 158
页数:7
相关论文
共 18 条
  • [1] [Anonymous], 2014, ELECT CONTACTS PRINC
  • [2] Bogatin E., 2015, Signal and Power Integrity: Simplified, V2nd
  • [3] The influence of contact interface characteristics on vibration-induced fretting degradation
    Flowers, GT
    Xie, F
    Bozack, M
    Horvath, R
    Rickett, BI
    Malucci, RD
    [J]. PROCEEDINGS OF THE FIFTY-FIRST IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, 2005, : 82 - 88
  • [4] Ji R, 2015, ELECTR CONTACT, P298, DOI 10.1109/HOLM.2015.7355112
  • [5] Simulation of lossy package transmission lines using extracted data from one-port TDR measurements and nonphysical RLGC models
    Kim, W
    Swaminathan, M
    [J]. IEEE TRANSACTIONS ON ADVANCED PACKAGING, 2005, 28 (04): : 736 - 744
  • [6] Kim Woopoung, 2002, P 6 IEEE WORKSH SIGN, P7
  • [7] Constriction resistance at high signal frequencies
    Lavers, JD
    Timsit, RS
    [J]. IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2002, 25 (03): : 446 - 452
  • [8] Li Qingya, 2016, Journal of China Universities of Posts and Telecommunications, V23, P61, DOI 10.1016/S1005-8885(16)60059-6
  • [9] Li Qingya, 2016, J CHINA U POSTS TELE, V23, P81
  • [10] Malucci RD, 2002, ELECTRICAL CONTACTS-2002: PROCEEDINGS OF THE FORTY-EIGHTH IEEE HOLM CONFERENCE ON ELECTRICAL CONTACTS, P212, DOI 10.1109/HOLM.2002.1040844