Application of comprehensive two-dimensional gas chromatography to sterols analysis

被引:28
|
作者
Mitrevski, Blagoj S. [1 ]
Brenna, J. Thomas [2 ]
Zhang, Y. [2 ]
Marriott, Philip J. [1 ]
机构
[1] RMIT Univ, Sch Appl Sci, Australian Ctr Res Separat Sci, Melbourne, Vic 3001, Australia
[2] Cornell Univ, Div Nutr Sci, Ithaca, NY 14853 USA
关键词
Comprehensive two-dimensional gas chromatography; GCxGC; Modulator temperature T-M; Doping control; Steriods; Flame ionisation detector; Time-of-flight mass spectrometry; Minimum acceptable match (MAM);
D O I
10.1016/j.chroma.2008.10.045
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The applicability of comprehensive two-dimensional gas chromatography (GCxGC) for sterol analysis was investigated by separation and identification of endogenous sterols in standards, and spiked in human urine. The modulation temperature was optimized to achieve the best separation and signal enhancement. The separation pattern of trimethylsilyl (TMS) derivatives of sterols was compared on two complementary column sets. Whilst the BPX5/BPX50 column set offers better overall separation, BPX50/BPX5 provides better peak shape and sensitivity. Comparison of the identification power of GCxGC-TOFMS against both the NIST05 MS library and a laboratory created (in-house) TOFMS library was carried out on a free sterols extract of urine, derivatised and spiked at the World Anti-Doping Agency (WADA) limit of 2 ng mL(-1). The average match quality for 19 analysed sterols on the BPX50/BPX5 column set was 950/1000 when searched against the in-house library; only four were identified against the NIST05 library, at a match threshold of 800. The match quality of GCxGC-TOFMS spectra was superior to that for analysis using 1D GC-TOFMS for sterols spiked in urine at 10 ng mL-1. An r(2) > 0.997 was obtained for the concentration range between 0.25 ng mL(-1) and 10 ng mL(-1) for three selected sterols. The lowest limit of detection (LOD) was obtained for estrone (0.1 ng mL(-1)) and the highest LOD was for 5 alpha-androstan-3 alpha,11 beta-diol-17-one, epitestosterone and cholesteryl butyrate (1 ng mL-1), using a match threshold of at least 800 and signal-to-noise ratio of at least 10. TOFMS coupled to GCxGC enabled satisfactory identification of sterols in urine at their LOD. A minimum acceptable match (MAM) criterion for urinary sterols using 2D retention times and TOF mass spectra is introduced. This study shows that GCxGC-TOFMS yields high specificity for steroids derived from urine, with detection limits appropriate for use in doping control. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:134 / 142
页数:9
相关论文
共 50 条
  • [11] Impact of comprehensive two-dimensional gas chromatography with mass spectrometry on food analysis
    Tranchida, Peter Q.
    Purcaro, Giorgia
    Maimone, Mariarosa
    Mondello, Luigi
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (01) : 149 - 161
  • [12] Parallel comprehensive two-dimensional gas chromatography
    Yan, DanDan
    Tedone, Laura
    Koutoulis, Anthony
    Whittock, Simon P.
    Shellie, Robert A.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1524 : 202 - 209
  • [13] Modulators for comprehensive two-dimensional gas chromatography
    Tranchida, Peter Quinto
    Purcaro, Giorgia
    Dugo, Paola
    Mondello, Luigi
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2011, 30 (09) : 1437 - 1461
  • [14] Comprehensive two-dimensional gas chromatography in metabolomics
    Martin F. Almstetter
    Peter J. Oefner
    Katja Dettmer
    Analytical and Bioanalytical Chemistry, 2012, 402 : 1993 - 2013
  • [15] Comprehensive two-dimensional gas chromatography improves separation and identification of anabolic agents in doping control
    Mitrevski, Blagoj S.
    Wilairat, Prapin
    Marriott, Philip J.
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (01) : 127 - 135
  • [16] Comprehensive two-dimensional gas chromatography in metabolomics
    Almstetter, Martin F.
    Oefner, Peter J.
    Dettmer, Katja
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (06) : 1993 - 2013
  • [17] Comprehensive two-dimensional gas chromatography: A perspective on processes of modulation
    Tranchida, Peter Q.
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1536 : 2 - 5
  • [18] Comprehensive two-dimensional gas chromatography of polybrominated diphenyl ethers
    Korytár, P
    Covaci, A
    Leonards, PEG
    de Boer, J
    Brinkman, UAT
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1100 (02) : 200 - 207
  • [19] The application of comprehensive two-dimensional gas chromatography to the analysis of wildfire debris for ignitable liquid residue
    Kates, Lisa N.
    Richards, Philip, I
    Sandau, Court D.
    FORENSIC SCIENCE INTERNATIONAL, 2020, 310
  • [20] Comprehensive two-dimensional gas chromatography applied to illicit drug analysis
    Mitrevski, Blagoj
    Wynne, Paul
    Marriott, Philip J.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (08) : 2361 - 2371