Multiscale segmentation of the skull in MR images for MRI-based attenuation correction of combined MR/PET

被引:24
|
作者
Yang, Xiaofeng [1 ]
Fei, Baowei [1 ,2 ,3 ,4 ,5 ]
机构
[1] Emory Univ, Ctr Syst Imaging, Dept Radiol & Imaging Sci, Atlanta, GA 30329 USA
[2] Emory Univ, Dept Biomed Engn, Atlanta, GA 30329 USA
[3] Georgia Inst Technol, Atlanta, GA 30332 USA
[4] Emory Univ, Winship Canc Inst, Atlanta, GA 30329 USA
[5] Emory Univ, Dept Math & Comp Sci, Atlanta, GA 30329 USA
关键词
Image segmentation; Attenuation correction; Multimodality Imaging; Combined MR; PET; Radon transform; multiscale bilateral filter; MEANS CLASSIFICATION METHOD; RESONANCE BRAIN IMAGES; AUTOMATIC SEGMENTATION; INTERVENTIONAL MRI; THERMAL ABLATION; PROSTATE-CANCER; LEVEL SET; REGISTRATION; EXTRACTION; MODEL;
D O I
10.1136/amiajnl-2012-001544
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Background and objective Combined magnetic resonance/positron emission tomography (MR/PET) is a relatively new, hybrid imaging modality. MR-based attenuation correction often requires segmentation of the bone on MR images. In this study, we present an automatic segmentation method for the skull on MR images for attenuation correction in brain MR/PET applications. Materials and methods Our method transforms T1-weighted MR images to the Radon domain and then detects the features of the skull image. In the Radon domain we use a bilateral filter to construct a multiscale image series. For the repeated convolution we increase the spatial smoothing in each scale and make the width of the spatial and range Gaussian function doubled in each scale. Two filters with different kernels along the vertical direction are applied along the scales from the coarse to fine levels. The results from a coarse scale give a mask for the next fine scale and supervise the segmentation in the next fine scale. The use of the multiscale bilateral filtering schemeis to improve the robustness of the method for noise MR images. After combining the two filtered sinograms, the reciprocal binary sinogram of the skull is obtained for the reconstruction of the skull image. Results This method has been tested with brain phantom data, simulated brain data, and real MRI data. For real MRI data the Dice overlap ratios are 92.2%1.9% between our segmentation and manual segmentation. Conclusions The multiscale segmentation method is robust and accurate and can be used for MRI-based attenuation correction in combined MR/PET.
引用
收藏
页码:1037 / 1045
页数:9
相关论文
共 50 条
  • [1] Skull segmentation of UTE MR images by probabilistic neural network for attenuation correction in PET/MR
    Santos Ribeiro, A.
    Kops, E. Rota
    Herzog, H.
    Almeida, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 702 : 114 - 116
  • [2] Validation of model-based pelvis bone segmentation from MR images for PET/MR attenuation correction
    Renisch, S.
    Blaffert, T.
    Tang, J.
    Hu, Z.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [3] MRI-based attenuation correction and quantification tools for combined MRI/PET
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon
    Jones, Margie
    Aarsvold, John
    Raghunath, Nivedita
    Meltzer, Carolyn
    Votaw, John
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [4] MR-Based PET Attenuation Correction for PET/MR Imaging
    Bezrukov, Ilja
    Mantlik, Frederic
    Schmidt, Holger
    Schoelkopf, Bernhard
    Pichler, Bernd J.
    SEMINARS IN NUCLEAR MEDICINE, 2013, 43 (01) : 45 - 59
  • [5] MR/PET quantification tools: Registration, segmentation, classification, and MR-based attenuation correction
    Fei, Baowei
    Yang, Xiaofeng
    Nye, Jonathon A.
    Aarsvold, John N.
    Raghunath, Nivedita
    Cervo, Morgan
    Stark, Rebecca
    Meltzer, Carolyn C.
    Votaw, John R.
    MEDICAL PHYSICS, 2012, 39 (10) : 6443 - 6454
  • [6] Evaluation of Segmentation Based Attenuation Correction Methods for PET/MR in the Thorax
    Ai, H.
    Pan, T.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] A Skull Segmentation Method for Brain MR Images Based on Multiscale Bilateral Filtering Scheme
    Yang, Xiaofeng
    Fei, Baowei
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [8] Toward Implementing an MRI-Based PET Attenuation-Correction Method for Neurologic Studies on the MR-PET Brain Prototype
    Catana, Ciprian
    van der Kouwe, Andre
    Benner, Thomas
    Michel, Christian J.
    Hamm, Michael
    Fenchel, Matthias
    Fischl, Bruce
    Rosen, Bruce
    Schmand, Matthias
    Sorensen, A. Gregory
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51 (09) : 1431 - 1438
  • [9] Attenuation Correction of PET/MR Using Deep Neural Network Based on Dixon and ZTE MR Images
    Gong, Kuang
    Yang, Jaewon
    Kim, Kyungsang
    El Fakhri, Georges
    Seo, Youngho
    Li, Quanzheng
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [10] Attenuation correction of the PET data with average MR in PET/MR
    Ai, Hua
    Pan, Tinsu
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53