A multicenter study on radiomic features from T2-weighted images of a customized MR pelvic phantom setting the basis for robust radiomic models in clinics

被引:27
作者
Bianchini, Linda [1 ,2 ]
Santinha, Joao [3 ,4 ]
Loucao, Nuno [5 ]
Figueiredo, Mario [4 ]
Botta, Francesca [6 ]
Origgi, Daniela [6 ]
Cremonesi, Marta [7 ]
Cassano, Enrico [8 ]
Papanikolaou, Nikolaos [3 ]
Lascialfari, Alessandro [9 ,10 ]
机构
[1] Univ Milan, Dept Phys, Via Celoria 16, I-20133 Milan, Italy
[2] INSTM RU, Via Celoria 16, I-20133 Milan, Italy
[3] Champalimaud Fdn, Ctr Unknown CCU, Computat Clin Imaging Grp, Lisbon, Portugal
[4] Univ Lisbon, Inst Telecomunicacoes, Inst Super Tecn, Lisbon, Portugal
[5] Philips Healthcare, Lisbon, Portugal
[6] European Inst Oncol IRCSS, Med Phys Unit, IEO, Milan, Italy
[7] European Inst Oncol IRCSS, Radiat Res Unit, IEO, Milan, Italy
[8] European Inst Oncol IRCSS, Breast Imaging Div, IEO, Milan, Italy
[9] Univ Pavia, Dept Phys, Pavia, Italy
[10] INSTM RU, Pavia, Italy
关键词
radiomic phantom; radiomics; repeatability; reproducibility; robustness; T-2-weighted magnetic resonance imaging; QUANTITATIVE IMAGING BIOMARKERS; STATISTICAL-METHODS; ACQUISITION; SIZE;
D O I
10.1002/mrm.28521
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To investigate the repeatability and reproducibility of radiomic features extracted from MR images and provide a workflow to identify robust features. Methods T-2-weighted images of a pelvic phantom were acquired on three scanners of two manufacturers and two magnetic field strengths. The repeatability and reproducibility of features were assessed by the intraclass correlation coefficient and the concordance correlation coefficient, respectively, and by the within-subject coefficient of variation, considering repeated acquisitions with and without phantom repositioning, and with different scanner and acquisition parameters. The features showing intraclass correlation coefficient or concordance correlation coefficient >0.9 were selected, and their dependence on shape information (Spearman's rho > 0.8) analyzed. They were classified for their ability to distinguish textures, after shuffling voxel intensities of images. Results From 944 two-dimensional features, 79.9% to 96.4% showed excellent repeatability in fixed position across all scanners. A much lower range (11.2% to 85.4%) was obtained after phantom repositioning. Three-dimensional extraction did not improve repeatability performance. Excellent reproducibility between scanners was observed in 4.6% to 15.6% of the features, at fixed imaging parameters. In addition, 82.4% to 94.9% of the features showed excellent agreement when extracted from images acquired with echo times 5 ms apart, but decreased with increasing echo-time intervals, and 90.7% of the features exhibited excellent reproducibility for changes in pulse repetition time. Of nonshape features, 2.0% was identified as providing only shape information. Conclusion We showed that radiomic features are affected by MRI protocols and propose a general workflow to identify repeatable, reproducible, and informative radiomic features to ensure robustness of clinical studies.
引用
收藏
页码:1713 / 1726
页数:14
相关论文
共 43 条
  • [1] MR Imaging Biomarkers in Oncology Clinical Trials
    Abramson, Richard G.
    Arlinghaus, Lori R.
    Dula, Adrienne N.
    Quarles, C. Chad
    Stokes, Ashley M.
    Weis, Jared A.
    Whisenant, Jennifer G.
    Chekmenev, Eduard Y.
    Zhukov, Igor
    Williams, Jason M.
    Yankeelov, Thomas E.
    [J]. MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2016, 24 (01) : 11 - +
  • [2] Highly efficient carrier multiplication in PbS nanosheets
    Aerts, Michiel
    Bielewicz, Thomas
    Klinke, Christian
    Grozema, Ferdinand C.
    Houtepen, Arjan J.
    Schins, Juleon M.
    Siebbeles, Laurens D. A.
    [J]. NATURE COMMUNICATIONS, 2014, 5
  • [3] Robustness and Reproducibility of Radiomics in Magnetic Resonance Imaging A Phantom Study
    Baessler, Bettina
    Weiss, Kilian
    dos Santos, Daniel Pinto
    [J]. INVESTIGATIVE RADIOLOGY, 2019, 54 (04) : 221 - 228
  • [4] PETER PHAN: An MRI phantom for the optimisation of radiomic studies of the female pelvis
    Bianchini, Linda
    Botta, Francesca
    Origgi, Daniela
    Rizzo, Stefania
    Mariani, Manuel
    Summers, Paul
    Garcia-Polo, Pablo
    Cremonesi, Marta
    Lascialfari, Alessandro
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 71 - 81
  • [5] Multisite evaluation of radiomic feature reproducibility and discriminability for identifying peripheral zone prostate tumors on MRI
    Chirra, Prathyush
    Leo, Patrick
    Yim, Michael
    Bloch, B. Nicolas
    Rastinehad, Ardeshir R.
    Purysko, Andrei
    Rosen, Mark
    Madabhushi, Anant
    Viswanath, Satish E.
    [J]. JOURNAL OF MEDICAL IMAGING, 2019, 6 (02)
  • [6] Gray-level discretization impacts reproducible MRI radiomics texture features
    Duron, Loic
    Balvay, Daniel
    Perre, Saskia Vande
    Bouchouicha, Afef
    Savatovsky, Julien
    Sadik, Jean-Claude
    Thomassin-Naggara, Isabelle
    Fournier, Laure
    Lecler, Augustin
    [J]. PLOS ONE, 2019, 14 (03):
  • [7] ExxonMobil, 2019, SPECTRASYN 4 POL PAO
  • [8] 3D Slicer as an image computing platform for the Quantitative Imaging Network
    Fedorov, Andriy
    Beichel, Reinhard
    Kalpathy-Cramer, Jayashree
    Finet, Julien
    Fillion-Robin, Jean-Christophe
    Pujol, Sonia
    Bauer, Christian
    Jennings, Dominique
    Fennessy, Fiona
    Sonka, Milan
    Buatti, John
    Aylward, Stephen
    Miller, James V.
    Pieper, Steve
    Kikinis, Ron
    [J]. MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1323 - 1341
  • [9] Repeatability and reproducibility of MRI-based radiomic features in cervical cancer
    Fiset, Sandra
    Welch, Mattea L.
    Weiss, Jessica
    Pintilie, Melania
    Conway, Jessica L.
    Milosevic, Michael
    Fyles, Anthony
    Traverso, Alberto
    Jaffra, David
    Metser, Ur
    Xie, Jason
    Han, Kathy
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 135 : 107 - 114
  • [10] Maximum tumor diameter: a simple independent predictor for biochemical recurrence after radical prostatectomy
    Fukuhara, H.
    Kume, H.
    Suzuki, M.
    Fujimura, T.
    Enomoto, Y.
    Nishimatsu, H.
    Ishikawa, A.
    Homma, Y.
    [J]. PROSTATE CANCER AND PROSTATIC DISEASES, 2010, 13 (03) : 244 - 247