Removal of heavy metals from aqueous solution by polyacrylic acid enhanced ultrafiltration

被引:17
作者
Ennigrou, Dorra Jellouli [1 ]
Ali, Mourad Ben Sik [2 ]
Dhahbi, Mahmoud [3 ]
Ferid, Mokhtar [1 ]
机构
[1] Natl Ctr Res Mat Sci, Phys Chem Lab Mineral Mat & Their Applicat, Soliman, Tunisia
[2] Fac Sci Tunis, Desalinat & Water Treatment Res Unit, El Manar 2092 2, Tunisia
[3] Water Res & Technol Ctr, Soliman, Tunisia
关键词
Cadmium; Copper; Zinc; Polyacrylic acid; Removal of ions; Polyelectrolyte-enhanced ultrafiltration; IONS; POLYMER; SEPARATION; BINDING; PERFORMANCE; MECHANISMS; RETENTION;
D O I
10.1080/19443994.2014.982958
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
One of the recently developed water treatment processes is the polyelectrolyte-enhanced ultrafiltration (PEUF). This technique combines a membrane filtration process (ultratfiltration) and a cation-polyectrolyte complexation technique. PEUF is shown to be an efficient technology for the removal of heavy metals from liquid effluents even at low concentrations. In this proposal, the removal of three heavy metals (cadmium, copper and zinc) from aqueous solutions by PEUF process was investigated. The poly(acrylic acid) (PAA) with an average molecular weight 100kDa was used as complexing agent. The ultrafiltration experiments were performed using a tangential cell system equipped with a polyethersulphone membrane having a 10.000 molecular weight cut-off (MWCO). To improve the retention of the heavy metal ions, the effect of some operating parameters and solution characteristics were studied. For different PAA concentrations, this study showed that all permeate fluxes increased linearly by increasing transmembrane pressure. For the three studied metals, the best retentions were observed at 2x10(-3)mol L-1 PAA concentration, 3bar transmembrane pressure and pH above 5. The removal of cadmium, copper and zinc exceeded, respectively, 80, 93 and 70%.
引用
收藏
页码:2682 / 2688
页数:7
相关论文
共 27 条
[1]   Mercury removal from aqueous solutions by complexation-ultrafiltration [J].
Barron-Zambrano, J ;
Laborie, S ;
Viers, PH ;
Rakib, M ;
Durand, G .
DESALINATION, 2002, 144 (1-3) :201-206
[2]   Potentiometric titration of poly(acrylic acid) in mixed counterion systems: Chemical binding of Cd ions [J].
Benegas, JC ;
Cleven, FMJ ;
van den Hoop, MAGT .
ANALYTICA CHIMICA ACTA, 1998, 369 (1-2) :109-114
[3]   Influence of adsorption and concentration polarisation on membrane performance during ultrafiltration of a non-ionic surfactant [J].
Byhlin, H ;
Jönsson, AS .
DESALINATION, 2003, 151 (01) :21-31
[4]  
CHAUFER B, 1988, Nuclear and Chemical Waste Management, V8, P175, DOI 10.1016/0191-815X(88)90025-3
[5]   MEMBRANE FOULING IN THE ULTRAFILTRATION OF POLYELECTROLYTE SOLUTIONS - POLYACRYLIC-ACID AND BOVINE SERUM-ALBUMIN [J].
CHOE, TB ;
MASSE, P ;
VERDIER, A ;
CLIFTON, MJ .
JOURNAL OF MEMBRANE SCIENCE, 1986, 26 (01) :17-30
[6]   Investigation of process performance and fouling mechanisms in micellar-enhanced ultrafiltration of nickel-contaminated waters [J].
Danis, Ummuhan ;
Aydiner, Coskun .
JOURNAL OF HAZARDOUS MATERIALS, 2009, 162 (2-3) :577-587
[7]   Modeling of ultrafiltration process for a two-component aqueous solution of low and high (gel-forming) molecular weight solutes [J].
De, S ;
Bhattacharya, PK .
JOURNAL OF MEMBRANE SCIENCE, 1997, 136 (1-2) :57-69
[8]   Use of micellar-enhanced ultrafiltration at low surfactant concentrations and with anionic-nonionic surfactant mixtures [J].
Fillipi, BR ;
Brant, LW ;
Scamehorn, JF ;
Christian, SD .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1999, 213 (01) :68-80
[9]   Removal of chromate anions by micellar-enhanced ultrafiltration using cationic surfactants [J].
Gzara, L ;
Dhahbi, M .
DESALINATION, 2001, 137 (1-3) :241-250
[10]   Ultrafiltration rejection of dissolved ions using various weakly basic water-soluble polymers [J].
Juang, RS ;
Chiou, CH .
JOURNAL OF MEMBRANE SCIENCE, 2000, 177 (1-2) :207-214