Early Studies of a Transmission Mechanism for MR-Guided Interventions

被引:0
|
作者
Zhao, Haoran [1 ]
Liu, Xin [2 ]
Zaid, Habib M. [2 ]
Shah, Dipan J. [3 ]
Heffernan, Michael J. [4 ]
Becker, Aaron T. [1 ]
Tsekos, Nikolaos V. [2 ]
机构
[1] Univ Houston, Dept Elect & Comp Engn, Houston, TX 77004 USA
[2] Univ Houston, Dept Comp Sci, Houston, TX 77204 USA
[3] Methodist DeBakey Heart & Vasc Ctr, Cardiovasc MRI Lab, Houston, TX USA
[4] GuidaBot LLC, Houston, TX USA
来源
2017 IEEE 17TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE) | 2017年
基金
美国国家科学基金会;
关键词
Solid media transmission; MR compatible; Robotic Actuator; COMPATIBLE ROBOTIC SYSTEM; MAGNETIC-RESONANCE; BRACHYTHERAPY; MOTION;
D O I
10.1109/BIBE.2017.00082
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnetic resonance imaging (MRI)-guided, manipulator-assisted interventions have the potential to improve patient outcomes. This work presents a force transmission mechanism, called solid-media transmission (SMT), for actuating manipulators inside MRI scanners. The SMT mechanism is based on conduits filled with spheres and spacers made of a nonmagnetic, nonconductive material that forms a backbone for bidirectional transmission. Early modeling and experimental studies assessed SMT and identified limitations and improvements. Simulations demonstrated the detrimental role of friction, which can be alleviated with a choice of low friction material and long spacers. However, the length of spacer is limited by the desired bending of the conduit. A closed-loop control law was implemented to drive the SMT. The 3rd order system fit ratio is 92.3%. A 1-m long SMT was experimentally tested under this closed-loop controller with heuristically set parameters using a customized benchtop setup. For commanded displacements of 1 to 50 mm, the SMT-actuated 1 degree of freedom stage exhibited sub-millimeter accuracy, which ranged from 0.109 +/- 0.057 mm to 0.045 +/- 0.029 mm depending on the commanded displacement. However, such accuracy required long control times inversely proportional to displacement ranging from 7.56 +/- 1.85s to 2.53 +/- 0.11s. This was attributed to friction as well as backlash which is due to suboptimal packing of the media. In MR studies, a 4-m long SMT-actuated 1 DoF manipulator was powered by a servo motor located inside the scanner room but outside the 5 Gauss line of the magnet. With shielding and filtering, the SNR of MR images during the operation of the servo motor and SMT-actuation was found to be 89 +/- 9% of the control case.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 50 条
  • [31] Sarcoma of the Heart Treated with Stereotactic MR-Guided Online Adaptive Radiation Therapy
    Pomp, Jacquelien
    van Asselen, Bram
    Tersteeg, Robbert H. A.
    Vink, Aryan
    Hassink, Rutger J.
    van der Kaaij, Niels P.
    van Aarnhem, Guido E. E. H. L.
    Verhoeff, Joost J. C.
    CASE REPORTS IN ONCOLOGY, 2021, 14 (01): : 453 - 458
  • [32] Safety of MR-guided focused ultrasound treatment of pedunculated subserosal uterine leiomyomas
    Brown, Douglas L.
    Hesley, Gina K.
    Gorny, Krzysztof R.
    Stewart, Elizabeth A.
    JOURNAL OF THERAPEUTIC ULTRASOUND, 2013, 1
  • [33] MR-guided SBRT boost for patients with locally advanced or recurrent gynecological cancers ineligible for brachytherapy: feasibility and early clinical experience
    Hadi, Indrawati
    Eze, Chukwuka
    Schoenecker, Stephan
    von Bestenbostel, Rieke
    Rogowski, Paul
    Nierer, Lukas
    Bodensohn, Raphael
    Reiner, Michael
    Landry, Guillaume
    Belka, Claus
    Niyazi, Maximilian
    Corradini, Stefanie
    RADIATION ONCOLOGY, 2022, 17 (01)
  • [34] MR-guided SBRT boost for patients with locally advanced or recurrent gynecological cancers ineligible for brachytherapy: feasibility and early clinical experience
    Indrawati Hadi
    Chukwuka Eze
    Stephan Schönecker
    Rieke von Bestenbostel
    Paul Rogowski
    Lukas Nierer
    Raphael Bodensohn
    Michael Reiner
    Guillaume Landry
    Claus Belka
    Maximilian Niyazi
    Stefanie Corradini
    Radiation Oncology, 17
  • [35] CT-guided versus MR-guided radiotherapy: Impact on gastrointestinal sparing in adrenal stereotactic body radiotherapy
    Rodriguez, Lori L.
    Kotecha, Rupesh
    Tom, Martin C.
    Chuong, Michael D.
    Contreras, Jessika A.
    Romaguera, Tino
    Alvarez, Diane
    McCulloch, James
    Herrera, Robert
    Hernandez, Rene J.
    Mercado, Jairo
    Mehta, Minesh P.
    Gutierrez, Alonso N.
    Mittauer, Kathryn E.
    RADIOTHERAPY AND ONCOLOGY, 2022, 166 : 101 - 109
  • [36] Prospective feasibility analysis of a novel off-line approach for MR-guided radiotherapy
    Bostel, Tilman
    Pfaffenberger, Asja
    Delorme, Stefan
    Dreher, Constantin
    Echner, Gernot
    Haering, Peter
    Lang, Clemens
    Splinter, Mona
    Laun, Frederik
    Mueller, Marco
    Jaekel, Oliver
    Debus, Juergen
    Huber, Peter E.
    Sterzing, Florian
    Nicolay, Nils H.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 (05) : 425 - 434
  • [37] MR-guided 125I seed implantation treatment for maxillofacial malignant tumor
    Wang, Ying
    Kang, Peng
    He, Wei
    Li, Rui
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (01): : 92 - 99
  • [38] Simulation-based graduate medical education in MR-guided brachytherapy for cervical cancer
    Singer, Lisa
    Mclaughlin, Pierre-Yves
    Alban, Gabriela
    Joyner, Melissa
    King, Martin
    Lee, Larissa
    BRACHYTHERAPY, 2020, 19 (06) : 725 - 731
  • [39] MR Imaging-Guided Cardiovascular Interventions in Young Children
    Tzifa, Aphrodite
    Schaeffter, Tobias
    Razavi, Reza
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2012, 20 (01) : 117 - +
  • [40] A Novel Concept of a Phased-Array HIFU Transducer Optimized for MR-Guided Hepatic Ablation: Embodiment and First In-Vivo Studies
    Lorton, Orane
    Guillemin, Pauline C.
    M'Rad, Yacine
    Peloso, Andrea
    Boudabbous, Sana
    Charbonnier, Caecilia
    Holman, Ryan
    Crowe, Lindsey A.
    Gui, Laura
    Poletti, Pierre-Alexandre
    Ricoeur, Alexis
    Terraz, Sylvain
    Salomir, Rares
    FRONTIERS IN ONCOLOGY, 2022, 12