Accuracy of oscillometric blood pressure monitors for the detection of atrial fibrillation: a systematic review

被引:0
|
作者
Verberk, Willem J. [1 ]
de Leeuw, Peter W.
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, Maastricht, Netherlands
关键词
arrhythmia; atrial fibrillation; blood pressure measurement; oscillometric blood pressure monitor; primary care; screening; stroke; EUROPEAN-SOCIETY; GENERAL-PRACTICE; PREVALENCE; GUIDELINES; MANAGEMENT; TRENDS; HOME; ESC;
D O I
10.1586/ERD.12.46
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Atrial fibrillation (AF) is a significant risk factor for stroke and early detection of AF may help to identify patients in need of treatment. Automated blood pressure (BP) monitors with implemented AF or arrhythmia detection systems may be a useful tool for early diagnosis of AF. A systematic review (Medline/PubMed, Embase, Cochrane) of studies was performed to assess the accuracy of modified BP monitors (for diagnosing AF). A total of five studies (four tests in the physician's office and one at home) were selected. For the most accurate AF detection, three sequential BP measurements should be performed. Direct comparison against a 12-lead ECG showed that the highest sensitivity, 97% (95% CI: 94-100%), for detecting AF was obtained when three readings were assessed with two or three AF-positive readings. The highest specificity (97%) was obtained when performing three measurements, of which all three must be AF positive. The modified BP monitor (Microlife Corporation, Taipei, Taiwan) has high potential in improving AF screening.
引用
收藏
页码:635 / 640
页数:6
相关论文
共 50 条
  • [21] Accuracy and feasibility of portable blood pressure monitoring in the detection of atrial fibrillation in hemodialysis patients
    AlAwwa, Izzat
    Saleh, Akram
    Wahbeh, Ayman M.
    Jallad, Shatha
    Ibrahim, Sarah
    Al-Awwa, Ahmad
    Farah, Randa I.
    REVIEWS IN CARDIOVASCULAR MEDICINE, 2021, 22 (01) : 225 - 229
  • [22] Auscultatory versus oscillometric blood pressure measurement in patients with atrial fibrillation and arterial hypertension
    Selmyte-Besuspare, Aisteja
    Barysiene, Jurate
    Petrikonyte, Dovile
    Aidietis, Audrius
    Marinskis, Germanas
    Laucevicius, Aleksandras
    BMC CARDIOVASCULAR DISORDERS, 2017, 17 : 87
  • [23] Effect of cuff positioning on the accuracy of blood pressure measurement with automated electronic blood pressure monitors
    Li, Ya
    Li, Fang
    Li, Yi
    Cui, Xiaoran
    Li, Jing
    Zhi, Hua
    Wang, Weidong
    Sun, Yanyan
    Cui, Wei
    JOURNAL OF CLINICAL HYPERTENSION, 2020, 22 (07): : 1163 - 1172
  • [24] Lifestyle risk reduction interventions in atrial fibrillation: a systematic review
    Lowres, Nicole
    Neubeck, Lis
    Ben Freedman, S.
    Briffa, Tom
    Bauman, Adrian
    Redfern, Julie
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2012, 19 (05) : 1091 - 1100
  • [25] Screening for Atrial Fibrillation During Routine Automated Blood Pressure Measurement in General Population Aged 65 Years and Above: EMENO National Epidemiological Survey in Greece
    Menti, Ariadni
    Kalpourtzi, Natasa
    Kyriakoulis, Konstantinos G.
    Kollias, Anastasios
    Touloumi, Giota
    Stergiou, George S.
    HIGH BLOOD PRESSURE & CARDIOVASCULAR PREVENTION, 2024, 31 (06) : 649 - 655
  • [26] Prognostic value of office blood pressure measurement in patients with atrial fibrillation on anticoagulation therapy: systematic review and meta-analysis
    Kollias, Anastasios
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Stergiou, George S.
    JOURNAL OF HYPERTENSION, 2020, 38 (01) : 13 - 20
  • [27] Diagnostic accuracy for detecting atrial fibrillation using a novel machine learning algorithm in a blood pressure monitor
    Janik, Matthew
    Raad, George
    Nijmeh, George
    O'Steen, Matthew
    Rasmussen, Jason
    HEART RHYTHM, 2024, 21 (10) : 2023 - 2027
  • [28] Diagnostic Performance of Automated Blood Pressure Monitor for Detection of Atrial Fibrillation
    Othman, Rasid
    Suliman, Ayman
    Yusof, Zurkurnai
    Isa, W. Yus Haniff W.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [29] Accuracy of methods for detecting an irregular pulse and suspected atrial fibrillation: A systematic review and meta-analysis
    Taggar, Jaspal S.
    Coleman, Tim
    Lewis, Sarah
    Heneghan, Carl
    Jones, Matthew
    EUROPEAN JOURNAL OF PREVENTIVE CARDIOLOGY, 2016, 23 (12) : 1330 - 1338
  • [30] Impact of Mobile Health Devices for the Detection of Atrial Fibrillation: Systematic Review
    Biersteker, Tom E.
    Schalij, Martin J.
    Treskes, Roderick W.
    JMIR MHEALTH AND UHEALTH, 2021, 9 (04):