Developments and Progress in Non-contact Eye Tonometer Calibration

被引:8
作者
Pavlasek, Peter [1 ,2 ]
Rybar, Jan [1 ]
Duris, Stanislav [1 ]
Hucko, Branislav [1 ]
Chytil, Miroslav [2 ]
Furdova, Alena [3 ]
Ferkova, Sylvia Lea [3 ]
Sekac, Juraj [3 ]
Suchy, Vitezslav [4 ]
Grosinger, Patrik [1 ]
机构
[1] Slovak Univ Technol Bratislava, Fac Mech Engn, Namestie Slobody 17, Bratislava 81231 1, Slovakia
[2] Slovak Inst Metrol, Karloveska 63, Bratislava 84255 4, Slovakia
[3] Comenius Univ, Fac Med, Dept Ophthalmol, Hosp Ruzinov, Ruzinovska 6, Bratislava 82606, Slovakia
[4] Czech Metrol Inst, Reg Inspectorate Most, Vladislava Vancury 1428-7, Most 43401, Czech Republic
关键词
Glaucoma; tonometry; IOP measurements; non-contact; calibration; standard; AIR-PUFF TONOMETER; INTRAOCULAR-PRESSURE; GOLDMANN APPLANATION; RELIABILITY;
D O I
10.2478/msr-2020-0021
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper focuses on the problematic of intraocular pressure (TOP) measurements, performed by non-invasive methods. More specifically, the devices that are connected with the presented finding are non-contact tonometers that use concentrated air stream and optical sensors to determine the TOP within a human's eye. The paper analyzes various influential factors that have an effect on the determination of the IOP values originating from the patients themselves and from the non-contact tonometer devices. The paper furthermore elaborates on the lack of independent methods of calibration and control of these devices. In order to fill this gap a measurement standard device that is capable of calibrating and testing these devices with traceability to the basic SI unit is presented. A detailed characterization and the determination of the expected uncertainty of the device are provided. By introducing an independent and traceable calibration method and control of non-contact tonometers into the clinical practice, the reliability of the measured IOP that is the primary indicator of glaucoma can be improved.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 2006, SYST INT UN
[2]   Comparative measurement of intraocular pressure by Icare tonometry and Airpuff tonometry in healthy subjects and patients wearing therapeutic soft contact lenses [J].
Anton, Alexandra ;
Neuburger, Matthias ;
Boehringer, Daniel ;
Jordan, Jens F. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (07) :1791-1795
[3]   Material Properties from Air Puff Corneal Deformation by Numerical Simulations on Model Corneas [J].
Bekesi, Nandor ;
Dorronsoro, Carlos ;
de la Hoz, Andres ;
Marcos, Susana .
PLOS ONE, 2016, 11 (10)
[4]   Comparative evaluation of intraocular pressure with an air-puff tonometer versus a Goldmann applanation tonometer [J].
Farhood, Qasim K. .
CLINICAL OPHTHALMOLOGY, 2013, 7 :23-27
[5]   Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact Tono/Pachymeter and Correlation of Central Corneal Thickness with Intraocular Pressure [J].
Fujimura, Fusako ;
Kamiya, Kazutaka ;
Fujiwara, Kazuko ;
Shoji, Nobuyuki ;
Shimizu, Kimiya .
BIOMED RESEARCH INTERNATIONAL, 2013, 2013
[6]   Reliability of the non-contact tono-pachymeter Tonopachy NT-530P in healthy eyes [J].
Garcia-Resua, Carlos ;
Pena-Verdeal, Hugo ;
Minones, Mercedes ;
Jesus Giraldez, M. ;
Yebra-Pimentel, Eva .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (03) :286-294
[7]  
Hornova J, 2013, Cesk Slov Oftalmol, V69, P175
[8]  
Hucko B., 2020, CURRENT METHODS CONS, P327
[9]  
International Organisation for Standardization, 2009, 86122009 ISO
[10]  
Jansson U., 2012, INT J OPHTHALMIC PRA, V3, P96