The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation

被引:22
|
作者
Duan, Yonghong [1 ,2 ]
Zhu, Shu [3 ]
Guo, Fei [4 ]
Zhu, Jinyu [1 ]
Li, Mao [1 ]
Ma, Jie [5 ]
Zhu, Qingsheng [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Orthoped Inst Chinese Peoples Liberat Army, Xian 710032, Shanxi, Peoples R China
[2] 451 Hosp Chinese Peoples Liberat Army, Dept Orthopaed Surg, Xian, Shanxi, Peoples R China
[3] Fourth Mil Med Univ, Dept Dent, Chinese Peoples Liberat Army, Xian 710032, Shanxi, Peoples R China
[4] Linton Sanitarium Chinese Peoples Liberat Army, Dept Orthopaed Surg, Xian, Shanxi, Peoples R China
[5] Fourth Mil Med Univ, Tangdu Hosp, Dept Neurosurg, Xian 710032, Shanxi, Peoples R China
关键词
hydroxyapatite coating; artificial joints; stability; biomechanical; adhesive strength; FEMORAL COMPONENTS; PARTICLES;
D O I
10.5114/aoms.2012.28545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: With the increase in joint revision surgery after arthroplasty, defects of hydroxyapatite (HA)-coated prostheses have been observed increasingly often. These defects adversely affect the prosthetic stability in vivo. This study has analyzed the potential effect of the adhesive strength of HA coating on the stability of HA-coated prostheses in vivo after its implantation. Material and methods: Sixty experimental rabbits were divided into HA- and Ti-coated groups. HA-coated prostheses were implanted into the bilateral epicondyle of rabbits femurs. Ti-coated prostheses were implanted as control. At different time points(4, 9, and 15 weeks) after implantation, bone tissue samples were fetched out respectively for histomorphometric analysis. Push-out testing was used to detect the ultimate shear strength at the bone-prosthesis interface. Scanning electron microscope (SEM) observation and energy-dispersive X-ray spectroscopy (EDX) analysis were used to observe the changes in surface composition of the prostheses after the ultimate shear strength testing. The coating adhesive strength of two kinds of coatings were also examined by scratch testing. Results: Hydroxyapatite coating has an obvious advantage in facilitating osteogenesis and its plays a critical role in the stability of prostheses. However, the ultimate shear strength of HA-coated prostheses is much lower than that of Ti-coated implants (p < 0.01). Further study has demonstrated that the stability of HA-coated prostheses in vivo is affected by the relatively low adhesive strength between coating and substrate. Conclusions: Obvious advantage in facilitating osteogenesis around HA-coated prostheses is not the only factor that determines the stability of prostheses in vivo.
引用
收藏
页码:199 / 208
页数:10
相关论文
共 50 条
  • [31] RADIOGRAPHIC PATTERNS IN TOTAL HIP-ARTHROPLASTY - HYDROXYAPATITE-COATED AND UNCOATED FEMORAL STEM PROSTHESES
    FOX, MG
    RAK, KM
    LISECKI, EJ
    CASTELLO, PH
    RADIOLOGY, 1995, 197 : 396 - 396
  • [32] In vitro and in vivo studies on bioactive hydroxyapatite-coated magnesium for glaucoma drainage implant
    Gao, Huanhuan
    Chen, Yi
    Chen, Xia
    Huang, Liandi
    Yao, Hao
    Zhu, Xiaomin
    Tang, Min
    Wang, Yong
    Li, Xiangji
    Xie, Lin
    JOURNAL OF MAGNESIUM AND ALLOYS, 2025, 13 (01) : 442 - 455
  • [33] Preoperative radiotherapy without femoral shielding for prevention of heterotopic ossification in hydroxyapatite-coated hip prostheses
    Taussky, D
    Cserhati, M
    Pescia, R
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2001, 121 (05) : 271 - 273
  • [34] Preoperative radiotherapy without femoral shielding for prevention of heterotopic ossification in hydroxyapatite-coated hip prostheses
    D. Taussky
    M. Cserhati
    R. Pescia
    Archives of Orthopaedic and Trauma Surgery, 2001, 121 : 271 - 273
  • [35] EFFECT OF DICLOFENAC ON FIXATION OF HYDROXYAPATITE-COATED IMPLANTS - AN EXPERIMENTAL-STUDY
    JACOBSSON, SA
    DJERF, K
    IVARSSON, I
    WAHLSTROM, O
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (05): : 831 - 833
  • [36] Ten-year results of ALIZE acetabular cup with hydroxyapatite coating and AURA hydroxyapatite-coated stem in total hip arthroplasty
    Fayard, Jean-Philippe
    Chalencon, Francois
    Passot, Jean-Paul
    Latour, Laurent Dupre
    Edorh, Gregoire
    JOURNAL OF ARTHROPLASTY, 2006, 21 (07): : 1021 - 1025
  • [37] Effect of morselized bones on binding of the canine hydroxyapatite-coated femoral stem
    SONG KeguanMA DeshengHOU JianwenWANG HuanYAN JinglongYU Zhange and LIANG Zhizhong Department of Orthopaedic SurgeryFirst Clinical Hospital of Harbin Medical UniversityHarbinHeilongjiang China Department of Orthopaedics Lianyungang No Hospital LianyungangJiangsu China
    中华医学杂志(英文版), 2010, (09) : 1163 - 1169
  • [38] THE EFFECT OF WARFARIN ON THE ATTACHMENT OF BONE TO HYDROXYAPATITE-COATED AND UNCOATED POROUS IMPLANTS
    CALLAHAN, BC
    LISECKI, EJ
    BANKS, RE
    DALTON, JE
    COOK, SD
    WOLFF, JD
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (02): : 225 - 230
  • [39] Evaluation of stability of titanium and hydroxyapatite-coated osseointegrated dental implants: a pilot study
    Simunek, A
    Vokurkova, J
    Kopecka, D
    Celko, M
    Mounajjed, R
    Krulichova, I
    Skrabkova, Z
    CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (01) : 75 - 79
  • [40] Enhanced Stability of Hydroxyapatite-coated Liposomes for Ultrasound-triggered Drug Release
    Ha, Jueng
    Cho, Sung Keun
    Park, Eun Seok
    Han, Kun
    Han, Hee Dong
    Shin, Byung Cheol
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2015, 36 (01): : 83 - 87