The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation

被引:22
|
作者
Duan, Yonghong [1 ,2 ]
Zhu, Shu [3 ]
Guo, Fei [4 ]
Zhu, Jinyu [1 ]
Li, Mao [1 ]
Ma, Jie [5 ]
Zhu, Qingsheng [1 ]
机构
[1] Fourth Mil Med Univ, Xijing Hosp, Orthoped Inst Chinese Peoples Liberat Army, Xian 710032, Shanxi, Peoples R China
[2] 451 Hosp Chinese Peoples Liberat Army, Dept Orthopaed Surg, Xian, Shanxi, Peoples R China
[3] Fourth Mil Med Univ, Dept Dent, Chinese Peoples Liberat Army, Xian 710032, Shanxi, Peoples R China
[4] Linton Sanitarium Chinese Peoples Liberat Army, Dept Orthopaed Surg, Xian, Shanxi, Peoples R China
[5] Fourth Mil Med Univ, Tangdu Hosp, Dept Neurosurg, Xian 710032, Shanxi, Peoples R China
关键词
hydroxyapatite coating; artificial joints; stability; biomechanical; adhesive strength; FEMORAL COMPONENTS; PARTICLES;
D O I
10.5114/aoms.2012.28545
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: With the increase in joint revision surgery after arthroplasty, defects of hydroxyapatite (HA)-coated prostheses have been observed increasingly often. These defects adversely affect the prosthetic stability in vivo. This study has analyzed the potential effect of the adhesive strength of HA coating on the stability of HA-coated prostheses in vivo after its implantation. Material and methods: Sixty experimental rabbits were divided into HA- and Ti-coated groups. HA-coated prostheses were implanted into the bilateral epicondyle of rabbits femurs. Ti-coated prostheses were implanted as control. At different time points(4, 9, and 15 weeks) after implantation, bone tissue samples were fetched out respectively for histomorphometric analysis. Push-out testing was used to detect the ultimate shear strength at the bone-prosthesis interface. Scanning electron microscope (SEM) observation and energy-dispersive X-ray spectroscopy (EDX) analysis were used to observe the changes in surface composition of the prostheses after the ultimate shear strength testing. The coating adhesive strength of two kinds of coatings were also examined by scratch testing. Results: Hydroxyapatite coating has an obvious advantage in facilitating osteogenesis and its plays a critical role in the stability of prostheses. However, the ultimate shear strength of HA-coated prostheses is much lower than that of Ti-coated implants (p < 0.01). Further study has demonstrated that the stability of HA-coated prostheses in vivo is affected by the relatively low adhesive strength between coating and substrate. Conclusions: Obvious advantage in facilitating osteogenesis around HA-coated prostheses is not the only factor that determines the stability of prostheses in vivo.
引用
收藏
页码:199 / 208
页数:10
相关论文
共 50 条
  • [21] EARLY CLINICAL-EXPERIENCE WITH HYDROXYAPATITE-COATED FEMORAL IMPLANTS
    DANTONIO, JA
    CAPELLO, WN
    CROTHERS, OD
    JAFFE, WL
    MANLEY, MT
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07): : 995 - 1008
  • [22] Fixation strength and pin tract infection of hydroxyapatite-coated tapered pins
    Moroni, A
    Heikkila, J
    Magyar, G
    Toksvig-Larsen, S
    Giannini, S
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (388) : 209 - 217
  • [23] HYDROXYAPATITE COATING OF HIP PROSTHESES - EFFECT ON MIGRATION INTO THE FEMUR
    KROON, PO
    FREEMAN, MAR
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1992, 74 (04): : 518 - 522
  • [24] NEW OBSERVATIONS ON MIDDLE TERM HYDROXYAPATITE-COATED TITANIUM-ALLOY HIP PROSTHESES
    FRAYSSINET, P
    HARDY, D
    ROUQUET, N
    GIAMMARA, B
    GUILHEM, A
    HANKER, J
    BIOMATERIALS, 1992, 13 (10) : 668 - 674
  • [25] The contribution of coating microstructure to degradation and particle release in hydroxyapatite coated prostheses
    Gross, KA
    Ray, N
    Rokkum, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2002, 63 (02): : 106 - 114
  • [26] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF SOLID HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    HAYASHI, K
    INADOME, T
    MASHIMA, T
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (05): : 557 - 563
  • [27] NATURAL-HISTORY OF BONE RESPONSE TO HYDROXYAPATITE-COATED HIP PROSTHESES IMPLANTED IN HUMANS
    FRAYSSINET, P
    HARDY, D
    HANKER, JS
    GIAMMARA, BL
    CELLS AND MATERIALS, 1995, 5 (02): : 125 - 138
  • [28] INCREASE OF STABILITY IN EXTERNAL FRACTURE FIXATION BY HYDROXYAPATITE-COATED BONE SCREWS
    AUGAT, P
    CLAES, L
    HANSELMANN, KF
    SUGER, G
    FLEISCHMANN, W
    JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (02) : 99 - 104
  • [29] Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
    David Campbell
    Graham Mercer
    Kjell G. Nilsson
    Vanessa Wells
    John R. Field
    Stuart A. Callary
    International Orthopaedics, 2011, 35 : 483 - 488
  • [30] Early migration characteristics of a hydroxyapatite-coated femoral stem: an RSA study
    Campbell, David
    Mercer, Graham
    Nilsson, Kjell G.
    Wells, Vanessa
    Field, John R.
    Callary, Stuart A.