Simultaneous and combined detection of multiple tumor biomarkers for prostate cancer in human serum by suspension array technology

被引:39
|
作者
Liu, Nan [1 ]
Liang, Wenfa [1 ]
Ma, Xinhua [1 ]
Li, Xiaoli [1 ]
Ning, Baoan [1 ]
Cheng, Chaonan [1 ]
Ou, Guorong [1 ]
Wang, Baogui [2 ]
Zhang, Juan [3 ]
Gao, Zhixian [1 ]
机构
[1] Inst Hlth & Environm Med, Tianjin Key Lab Risk Assessment & Control Technol, Tianjin 300050, Peoples R China
[2] Tianjin Med Univ Canc Inst & Hosp, Dept Gastr Canc Surg, Tianjin Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
[3] Tianjin Med Univ, Hosp 2, Dept Clin Lab, Tianjin 300211, Peoples R China
来源
关键词
Tumor markers (TMs); Prostate cancer (PCa); Suspension array; Median Fluorescent Intensity (MFI); STEM-CELL ANTIGEN; MEMBRANE ANTIGEN; ACID-PHOSPHATASE; RAPID DETECTION; IN-VIVO; MARKER; CHLORAMPHENICOL; MICROCARRIERS; IMMUNOASSAY; EXPRESSION;
D O I
10.1016/j.bios.2013.02.052
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Tumor markers (TMs) play an important role in clinical rapid screening and diagnosis for prostate cancer (PCa). In this study, we describe a competitive method to establish the multiplex suspension array by tumor biomarkers coated on distinguishable microbeads which competing with free biomarkers for their complementary antibodies (Ab) in one single reaction system for simultaneous and combined detection of prostate TMs in human serum. The volumes of the targets coupled onto the beads and their complementary Abs were optimized. The suspension array standard curves correlated well with PCa biomarkers (R-2 > 0.9968). PCa biomarker levels were quantified using median fluorescent intensities. The working ranges of prostate-specific antigen (PSA), prostate stem cell antigen (PSCA), prostate-specific membrane antigen (PSMA) and prostatic acid phosphatase (PAP) were 0.47-502.94, 1.00-923.35, 1.00-524.79, and 1.73-176.07 ng mL(-1) in serum samples, respectively. This method was compared to indirect competitive enzyme linked immunosorbent assay. It was found that high concordance between the two technologies resulted from serum samples of the eight PCa patients. The multiplex suspension array technology is specific to PCa biomarkers, displayed no significant cross-reactivity, and remains stable for 6 months. We also characterized the bead surface microstructures under different conditions employing a field emission scanning electron microscope. The suspension array is a straightforward and reliable method for analysis of multiple TMs with simple operation, high sensitivity at a low cost. (C) 2013 Elsevier E.V. All rights reserved.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [41] Identification and characterization of tumor-associated antigens as biomarkers in human prostate cancer
    Li, Jitian
    Dai, Liping
    Casiano, Carlos A.
    Zhang, Jianying
    CANCER RESEARCH, 2014, 74 (19)
  • [42] Prostate cancer detection and tumor characteristics in men with multiple biopsy sessions
    M Lujan
    A Paez
    C Santonja
    T Pascual
    I Fernandez
    A Berenguer
    Prostate Cancer and Prostatic Diseases, 2004, 7 : 238 - 242
  • [43] Prostate cancer detection and tumor characteristics in men with multiple biopsy sessions
    Lujan, M
    Paez, A
    Santonja, C
    Pascual, T
    Fernandez, I
    Berenguer, A
    PROSTATE CANCER AND PROSTATIC DISEASES, 2004, 7 (03) : 238 - 242
  • [44] Simultaneous quantification of carcinoembryonic antigen (CEA), alpha fetoprotein (AFP), and hepatitis B surface antigen (HBSAG) in human serum using suspension array technology
    Wei, C.
    Yinsong, W.
    Weiwen, X.
    Yunshan, N.
    Ming, L.
    MOLECULAR & CELLULAR PROTEOMICS, 2005, 4 (08) : S337 - S337
  • [45] Simultaneous and highly sensitive detection of six different foodborne pathogens by high-throughput suspension array technology
    Sun, Zhiyong
    Peng, Yuan
    Zhang, Manci
    Wang, Kun
    Bai, Jialei
    Li, Xiaoli
    Ning, Baoan
    Gao, Zhixian
    FOOD CONTROL, 2014, 40 : 300 - 309
  • [46] Multiplex analysis of serum biomarkers in colorectal cancer patients using Bio-Plex® suspension array system
    Gupta, Vinita
    Yamada, Yasuhide
    Arao, Tokuzo
    Nishio, Kazuto
    Tan, Woei
    Fedynyshyn, Joseph
    CANCER RESEARCH, 2009, 69
  • [47] Quantum-dots based simultaneous detection of multiple biomarkers of tumor stromal features to predict clinical outcomes in gastric cancer
    Peng, Chun-Wei
    Tian, Qian
    Yang, Gui-Fang
    Fang, Min
    Zhang, Zhi-Ling
    Peng, Jun
    Li, Yan
    Pang, Dai-Wen
    BIOMATERIALS, 2012, 33 (23) : 5742 - 5752
  • [48] A High-Throughput Cantilever Array Sensor for Multiple Liver Cancer Biomarkers Detection
    Wang, Jingjing
    Zhu, Yinfang
    Wang, Xing
    Wang, Shuaipeng
    Yang, Jinling
    Yang, Fuhua
    IEEE SENSORS JOURNAL, 2016, 16 (12) : 4675 - 4682
  • [49] Wearable Eye Patch Biosensor for Noninvasive and Simultaneous Detection of Multiple Biomarkers in Human Tears
    Xu, Jia
    Tao, Xiaoqin
    Liu, Xiaoxuan
    Yang, Li
    ANALYTICAL CHEMISTRY, 2022, 94 (24) : 8659 - 8667
  • [50] Nanomechanical Biomarkers of Single Circulating Tumor Cells for Detection of Castration Resistant Prostate Cancer
    Osmulski, Pawel
    Mahalingam, Devalingam
    Gaczynska, Maria E.
    Liu, Joseph
    Huang, Susan
    Horning, Aaron M.
    Wang, Chiou-Miin
    Thompson, Ian M.
    Huang, Tim H. -M.
    Chen, Chun-Liang
    PROSTATE, 2014, 74 (13): : 1297 - 1307