Simultaneous and combined detection of multiple tumor biomarkers for prostate cancer in human serum by suspension array technology

被引:39
|
作者
Liu, Nan [1 ]
Liang, Wenfa [1 ]
Ma, Xinhua [1 ]
Li, Xiaoli [1 ]
Ning, Baoan [1 ]
Cheng, Chaonan [1 ]
Ou, Guorong [1 ]
Wang, Baogui [2 ]
Zhang, Juan [3 ]
Gao, Zhixian [1 ]
机构
[1] Inst Hlth & Environm Med, Tianjin Key Lab Risk Assessment & Control Technol, Tianjin 300050, Peoples R China
[2] Tianjin Med Univ Canc Inst & Hosp, Dept Gastr Canc Surg, Tianjin Key Lab Canc Prevent & Therapy, Tianjin 300060, Peoples R China
[3] Tianjin Med Univ, Hosp 2, Dept Clin Lab, Tianjin 300211, Peoples R China
来源
关键词
Tumor markers (TMs); Prostate cancer (PCa); Suspension array; Median Fluorescent Intensity (MFI); STEM-CELL ANTIGEN; MEMBRANE ANTIGEN; ACID-PHOSPHATASE; RAPID DETECTION; IN-VIVO; MARKER; CHLORAMPHENICOL; MICROCARRIERS; IMMUNOASSAY; EXPRESSION;
D O I
10.1016/j.bios.2013.02.052
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Tumor markers (TMs) play an important role in clinical rapid screening and diagnosis for prostate cancer (PCa). In this study, we describe a competitive method to establish the multiplex suspension array by tumor biomarkers coated on distinguishable microbeads which competing with free biomarkers for their complementary antibodies (Ab) in one single reaction system for simultaneous and combined detection of prostate TMs in human serum. The volumes of the targets coupled onto the beads and their complementary Abs were optimized. The suspension array standard curves correlated well with PCa biomarkers (R-2 > 0.9968). PCa biomarker levels were quantified using median fluorescent intensities. The working ranges of prostate-specific antigen (PSA), prostate stem cell antigen (PSCA), prostate-specific membrane antigen (PSMA) and prostatic acid phosphatase (PAP) were 0.47-502.94, 1.00-923.35, 1.00-524.79, and 1.73-176.07 ng mL(-1) in serum samples, respectively. This method was compared to indirect competitive enzyme linked immunosorbent assay. It was found that high concordance between the two technologies resulted from serum samples of the eight PCa patients. The multiplex suspension array technology is specific to PCa biomarkers, displayed no significant cross-reactivity, and remains stable for 6 months. We also characterized the bead surface microstructures under different conditions employing a field emission scanning electron microscope. The suspension array is a straightforward and reliable method for analysis of multiple TMs with simple operation, high sensitivity at a low cost. (C) 2013 Elsevier E.V. All rights reserved.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [31] Detection of three tumor biomarkers in human lung cancer serum using single particle inductively coupled plasma mass spectrometry combined with magnetic immunoassay
    Cao, Yupin
    Feng, Jinsu
    Tang, Lifu
    Mo, Guichun
    Mo, Weiming
    Deng, Biyang
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 166
  • [32] Electro-nano Diagnostic Platforms for Simultaneous Detection of Multiple Cancer Biomarkers
    Kalyoncu, Dorukhan
    Tepeli, Yudum
    Kirgoz, Umut Can
    Buyrac, Arda
    Anik, Ulku
    ELECTROANALYSIS, 2017, 29 (12) : 2832 - 2838
  • [33] Simultaneous detection of multiple phosphorylated and total proteins from a Bio-Plex™ suspension array system
    Gao, Q
    Simonyi, K
    Suen, C
    Zhu-Shimoni, J
    Allauzen, S
    MOLECULAR BIOLOGY OF THE CELL, 2004, 15 : 17A - 17A
  • [34] The combined use of urine and serum biomarkers in early detection strategies for pancreatic cancer
    Nolen, Brian M.
    Lomakin, Aleksey
    Grizzle, William E.
    Jhala, Nirag
    Eloubeidi, Mohamad A.
    Christein, John D.
    Arnoletti, Juan P.
    Oelschlager, Denise K.
    Vickers, Selwyn M.
    Lokshin, Anna E.
    CANCER RESEARCH, 2011, 71
  • [35] Is there a role for serum human tissue kallikrein in detection of prostate cancer?
    Ochiai, Atsushi
    Shukla, Ashish
    Davis, John W.
    Fritsche, Herbert A.
    Bhadkamkar, Viju
    Babaian, R. Joseph
    UROLOGY, 2007, 70 (03) : 519 - 522
  • [36] Redox-labelled detection probe enabled immunoassay for simultaneous detection of multiple cancer biomarkers
    Chellachamy Anbalagan, Amarnath
    Sawant, Shilpa N.
    MICROCHIMICA ACTA, 2023, 190 (03)
  • [37] Redox-labelled detection probe enabled immunoassay for simultaneous detection of multiple cancer biomarkers
    Amarnath Chellachamy Anbalagan
    Shilpa N. Sawant
    Microchimica Acta, 2023, 190
  • [38] Search for human prostate cancer biomarkers in serum of xenograft-bearing mice
    Jansen, F.
    Krijgsveld, J.
    Van Den Bemd, G. J.
    Van Rijswijk, A.
    Demmers, J.
    Jenster, G.
    EUROPEAN UROLOGY SUPPLEMENTS, 2007, 6 (02) : 148 - 148
  • [39] Non-invasive SERS serum detection technology combined with multivariate statistical algorithm for simultaneous screening of cervical cancer and breast cancer
    Gao, Ningning
    Wang, Qing
    Tang, Jun
    Yao, Shengyuan
    Li, Hongmei
    Yue, Xiaxia
    Fu, Jihong
    Zhong, Furu
    Wang, Tao
    Wang, Jing
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2021, 413 (19) : 4775 - 4784
  • [40] Non-invasive SERS serum detection technology combined with multivariate statistical algorithm for simultaneous screening of cervical cancer and breast cancer
    Ningning Gao
    Qing Wang
    Jun Tang
    Shengyuan Yao
    Hongmei Li
    Xiaxia Yue
    Jihong Fu
    Furu Zhong
    Tao Wang
    Jing Wang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4775 - 4784