Ammonium ion sensor based on photocured and self-plasticising acrylic films for the analysis of sewage

被引:39
作者
Heng, LY [1 ]
Alva, S [1 ]
Ahmad, M [1 ]
机构
[1] Univ Kebangsaan Malaysia, Sch Chem Sci & Food Technol, Fac Sci & Technol, Bangi 43600, Malaysia
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2004年 / 98卷 / 2-3期
关键词
photocure; poly(butyl acrylate) membrane; self-plasticising; ammonium ion sensor; sewage;
D O I
10.1016/j.snb.2003.09.032
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Solid-state ammonium ion sensors based on photocured poly(n-butyl acrylate) membrane with immobilised nonactin is successfully used for the determination of ammonium ion. The sensor membrane does not require any plasticiser and gives Nernstian response (57-58 mV per decade) throughout the ammonium ion concentration range of 10(-1) to 10(-5) M with detection limits approaching 10(-6) M ammonium ion. The sensor also demonstrates good reproducibility (R.S.D. 2-4%, n = 15) and satisfactory selectivity with improved selectivity coefficients for sodium, lithium, calcium and magnesium over other ammonium sensors fabricated by similar photocuring technique. The ammonium ion sensor has potential application in the analysis of ammonium and ammonia in sewage samples. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:160 / 165
页数:6
相关论文
共 33 条
[21]   NEW PHOTOCURABLE COMPOSITION FOR ISFET POLYMER MEMBRANES [J].
LEVICHEV, SS ;
BRATOV, AV ;
VLASOV, YG .
SENSORS AND ACTUATORS B-CHEMICAL, 1994, 19 (1-3) :625-628
[22]   Flow-injection analysis of Kjeldahl nitrogen in milk and dairy products by potentiometric detection [J].
Lima, JFCC ;
Delerue-Matos, C ;
Vaz, MC .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :437-441
[23]   Array of potentiometric sensors for the analysis of creatinine in urine samples [J].
Magalhaes, JMCS ;
Machado, AASC .
ANALYST, 2002, 127 (08) :1069-1075
[24]   Novel approach of immobilization of calix[4]arene type ionophore in 'self-plasticized' polymeric membrane [J].
Malinowska, E ;
Gawart, L ;
Parzuchowski, P ;
Rokicki, G ;
Brzózka, Z .
ANALYTICA CHIMICA ACTA, 2000, 421 (01) :93-101
[25]   Detection limit of polymeric membrane potentiometric ion sensors: how can we go down to trace levels? [J].
Mi, YM ;
Mathison, S ;
Goines, R ;
Logue, A ;
Bakker, E .
ANALYTICA CHIMICA ACTA, 1999, 397 (1-3) :103-111
[26]  
MOODY GJ, 1988, SELECT ELECTR REV, V10, P71
[27]  
MOODY GJ, 1992, BIOSENSORS CHEM SENS, P100
[28]  
MOSTERT IA, 1985, MIKROCHIM ACTA, V1, P33
[29]   AMMONIUM ION SENSOR BASED ON IMMOBILIZED NITRIFYING BACTERIA AND A CATION-EXCHANGE MEMBRANE [J].
OKADA, T ;
KARUBE, I ;
SUZUKI, S .
ANALYTICA CHIMICA ACTA, 1982, 135 (01) :159-163
[30]  
PALLESCHI G, 1988, ANAL LETT, V21, P1115