A Figure-of-Merit for Design and Optimization of Inductive Power Transmission Links for Millimeter-Sized Biomedical Implants

被引:74
作者
Ibrahim, Ahmed [1 ]
Kiani, Mehdi [1 ]
机构
[1] Penn State Univ, Dept Elect Engn, University Pk, PA 16802 USA
关键词
Inductive links; mm-sized biomedical implants; optimal operating frequency; wireless power transmission; PRINTED SPIRAL COILS; FREQUENCY;
D O I
10.1109/TBCAS.2016.2515541
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Power transmission efficiency (PTE) has been the key parameter for wireless power transmission (WPT) to biomedical implants with millimeter (mm) dimensions. It has been suggested that for mm-sized implants increasing the power carrier frequency (f(p)) of the WPT link to hundreds of MHz improves PTE. However, increasing f(p) significantly reduces the maximum allowable power that can be transmitted under the specific absorption rate (SAR) constraints. This paper presents a new figure-of-merit (FoM) and a design methodology for optimal WPT to mm-sized implants via inductive coupling by striking a balance between PTE and maximum delivered power under SAR constraints (P-L,P-SAR). First, the optimal mm-sized receiver (Rx) coil geometry is identified for a wide range of f(p) to maximize the Rx coil quality factor. Secondly, the optimal transmitter (Tx) coil geometry and f(p) are found to maximize the proposed FoM under a low-loss Rx matched-load condition. Finally, proper Tx coil and tissue spacing is identified based on FoM at the optimal f(p). We demonstrate that f(p) in order of tens of MHz still offer higher P-L,P-SAR and FoM, which is key in applications that demand high power such as optogenetics. An inductive link to power a 1 mm(3) implant was designed based on our FoM and verified through full-wave electromagnetic field simulations and measurements using de-embedding method. In our measurements, an Rx coil with 1 mm diameter, located 10 mm inside the tissue, achieved PTE and P-L,P-SAR of 1.4% and 2.2 mW at f(p) of 20 MHz, respectively.
引用
收藏
页码:1100 / 1111
页数:12
相关论文
共 39 条
[1]   Optimal Design of Wireless Power Transmission Links for Millimeter-Sized Biomedical Implants [J].
Ahn, Dukju ;
Ghovanloo, Maysam .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2016, 10 (01) :125-137
[2]  
[Anonymous], 2011, 2011 DESIGN AUTOMATI, DOI DOI 10.1109/DATE.2011.5763123
[3]  
[Anonymous], 2019, IEEEC951
[4]  
[Anonymous], FCC OET B SC, V65
[5]  
[Anonymous], 2003, RFID HDB FUNDAMENTAL
[6]   Feedback Analysis and Design of RF Power Links for Low-Power Bionic Systems [J].
Baker, Michael W. ;
Sarpeshkar, Rahul .
IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2007, 1 (01) :28-38
[7]   A Fully-Integrated, Miniaturized (0.125 mm2) 10.5 μW Wireless Neural Sensor [J].
Biederman, William ;
Yeager, Daniel J. ;
Narevsky, Nathan ;
Koralek, Aaron C. ;
Carmena, Jose M. ;
Alon, Elad ;
Rabaey, Jan M. .
IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2013, 48 (04) :960-970
[8]   Design of Wireless Links to Implanted Brain-Machine Interface Microelectronic Systems [J].
Bjorninen, Toni ;
Muller, Rikky ;
Ledochowitsch, Peter ;
Sydanheimo, Lauri ;
Ukkonen, Leena ;
Maharbiz, Michel M. ;
Rabaey, Jan M. .
IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2012, 11 :1663-1666
[9]   A 3-STEP METHOD FOR THE DE-EMBEDDING OF HIGH-FREQUENCY S-PARAMETER MEASUREMENTS [J].
CHO, HJ ;
BURK, DE .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1991, 38 (06) :1371-1375
[10]   Assessing Human Exposure to Electromagnetic Fields From Wireless Power Transmission Systems [J].
Christ, Andreas ;
Douglas, Mark ;
Nadakuduti, Jagadish ;
Kuster, Niels .
PROCEEDINGS OF THE IEEE, 2013, 101 (06) :1482-1493