Simultaneous, accurate measurement of the 3D position and orientation of single molecules

被引:151
作者
Backlund, Mikael P. [1 ]
Lew, Matthew D. [1 ,2 ]
Backer, Adam S. [1 ,3 ]
Sahl, Steffen J. [1 ]
Grover, Ginni [4 ]
Agrawal, Anurag [4 ]
Piestun, Rafael [4 ]
Moerner, W. E. [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
[3] Stanford Univ, Inst Computat & Math Engn, Stanford, CA 94305 USA
[4] Univ Colorado, Dept Elect Comp & Energy Engn, Boulder, CO 80309 USA
基金
美国国家科学基金会;
关键词
OPTICAL RECONSTRUCTION MICROSCOPY; POINT-SPREAD FUNCTION; SUPERRESOLUTION MICROSCOPY; FLUORESCENCE MICROSCOPY; DIFFRACTION-LIMIT; LOCALIZATION; SPECTROSCOPY; TRACKING; EMITTERS; MOTORS;
D O I
10.1073/pnas.1216687109
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule's 3D orientation and z position. Failure to account for this fact can lead to significant lateral (x, y) mislocalizations (up to similar to 50-200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from similar to 2x worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (similar to 4x worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit).
引用
收藏
页码:19087 / 19092
页数:6
相关论文
共 50 条
  • [21] Hybrid Visual and Inertial Position and Orientation Estimation based on Known Urban 3D Models
    Antigny, Nicolas
    Servieres, Myriam
    Renaudin, Valerie
    2016 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION (IPIN), 2016,
  • [22] Single-Molecule Real-Time 3D Imaging of the Transcription Cycle by Modulation Interferometry
    Wang, Guanshi
    Hauver, Jesse
    Thomas, Zachary
    Darst, Seth A.
    Pertsinidis, Alexandros
    CELL, 2016, 167 (07) : 1839 - +
  • [23] Development of 3D crystallographic orientation measurement for grain deformation analysis in aluminum alloy
    Kobayashi, M.
    Toda, H.
    Leclere, D. J.
    Kamiko, T.
    Uesugi, K.
    Takeuchi, A.
    Suzuki, Y.
    TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2014, 24 (07) : 2094 - 2101
  • [24] Computational correction of spatially variant optical aberrations in 3D single-molecule localization microscopy
    Yan, T.
    Richardson, C. J.
    Zhang, M.
    Gahlmann, A.
    OPTICS EXPRESS, 2019, 27 (09) : 12582 - 12599
  • [25] Combining 3D single molecule localization strategies for reproducible bioimaging
    Cabriel, Clement
    Bourg, Nicolas
    Jouchet, Pierre
    Dupuis, Guillaume
    Leterrier, Christophe
    Baron, Aurelie
    Badet-Denisot, Marie-Ange
    Vauzeilles, Boris
    Fort, Emmanuel
    Leveque-Fort, Sandrine
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [26] Radiation measurement and imaging using 3D position sensitive pixelated CZT detector
    Kim, Younghak
    Lee, Taewoong
    Lee, Wonho
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2019, 51 (05) : 1417 - 1427
  • [27] Cramer-Rao Lower Bounds on 3D Position and Orientation Estimation in Distributed Ranging Systems
    Srinivas, Sharanya
    Welker, Samuel
    Herschfelt, Andrew
    Bliss, Daniel W. W.
    APPLIED SCIENCES-BASEL, 2023, 13 (03):
  • [28] Optimal 3D single-molecule localization for superresolution microscopy with aberrations and engineered point spread functions
    Quirin, Sean
    Pavani, Sri Rama Prasanna
    Piestun, Rafael
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2012, 109 (03) : 675 - 679
  • [29] Localization microscopy of single molecules enhanced by 3D imaging and light sheet illumination
    Moerner, W. E.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2019, 52 (01)
  • [30] Maximizing the field of view and accuracy in 3D Single Molecule Localization Microscopy
    Rehman, Sohaib Abdul
    Carr, Alexander R.
    Lenz, Martin O.
    Lee, Steven F.
    O'Holleran, Kevin
    OPTICS EXPRESS, 2018, 26 (04): : 4631 - 4637