An original multi-objective criterion for the design of small-scale polygeneration systems based on realistic operating conditions

被引:74
作者
Piacentino, A. [1 ]
Cardona, F. [1 ]
机构
[1] Univ Palermo, Fac Engn, DREAM Dept Energet & Environm Res, I-90128 Palermo, Italy
关键词
Cogeneration; Trigeneration; Management strategy; Energy saving; Optimization; Plant design;
D O I
10.1016/j.applthermaleng.2008.01.017
中图分类号
O414.1 [热力学];
学科分类号
摘要
The optimal design and operation of cogeneration and trigeneration systems for buildings applications is a complex issue, which has been investigated by several different approaches. Both the two basic management strategies, namely heat-tracking and electricity-tracking, have advantages and drawbacks in terms of operating results and may lead the plant designer either to undersize or oversize the CHP unit with respect to the optimal lay-out. Experimental works have demonstrated how the actual on-site performance of small-scale poly-generation systems significantly differs from their expected operation, due to the need for a regular plant operation and the effects of outages for scheduled or unscheduled maintenance activities. After pointing out that heuristic approaches based on demand duration curve are weak instruments for plant design optimization, a more refined method is proposed, based on realistic operating conditions. The method integrates results of previous researches, like the proven convenience in using a duration curve of the "aggregate thermal demand" and in adopting flexible and techno-economically feasible management strategies; it is also based on original indicators to be used for the real time optimization of plant operation. The proposed hybrid management criterion represents a good compromise between profit-oriented and emergo-environment-oriented solutions, ensuring the combined production system to be eligible for support mechanisms. Finally, the method is applied for demonstrative purposes to a large hotel situated in Italy; implementing the innovative phases of the method by successive steps allowed to recognize what margins for profitability and energy saving each phase provides, (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2391 / 2404
页数:14
相关论文
共 18 条
[1]   Experimental analysis of the actual behaviour of a natural gas fueled engine Caterpillar (CAT)-3516 [J].
Bidini, G ;
Grimaldi, CN ;
Mariani, F .
APPLIED THERMAL ENGINEERING, 2000, 20 (05) :455-470
[2]   A methodology for sizing a trigeneration plant in mediterranean areas [J].
Cardona, E ;
Piacentino, A .
APPLIED THERMAL ENGINEERING, 2003, 23 (13) :1665-1680
[3]  
Cardona E, 2001, CHOSE ENERGY SAVING
[4]  
CARDONA E, 2005, DABASI WWW PROMOTION
[5]   Matching economical, energetic and environmental benefits: An analysis for hybrid CHCP-heat pump systems [J].
Cardona, Ennio ;
Piacentino, Antonio ;
Cardona, Fabio .
ENERGY CONVERSION AND MANAGEMENT, 2006, 47 (20) :3530-3542
[6]   Scheduling of cogeneration plants considering electricity wheeling using enhanced immune algorithm [J].
Chen, SL ;
Tsay, MT ;
Gow, HJ .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2005, 27 (01) :31-38
[7]  
*COG EUR, ENK5CT200120544 COG
[8]   Optimal operation of a complex thermal system: a case study [J].
d'Accadia, MD .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2001, 24 (04) :290-301
[9]   Influences of thermal and electric load fluctuations in the cogeneration attractiveness [J].
Ernst, Mario A. Basulto ;
Balestieri, Jose A. Perrella .
APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) :1500-1505
[10]   Optimal unit sizing of cogeneration systems in consideration of uncertain energy demands as continuous random variables [J].
Gamou, S ;
Yokoyama, R ;
Ito, K .
ENERGY CONVERSION AND MANAGEMENT, 2002, 43 (9-12) :1349-1361