Temporal Trends in Strut-Level Optical Coherence Tomography Evaluation of Coronary Stent Coverage: A Systematic Review and Meta-Analysis

被引:12
|
作者
Lee, Kwan S. [1 ]
Lee, Justin Z. [1 ]
Hsu, Chiu-Hsieh [1 ]
Husnain, Muhammad [1 ]
Riaz, Haris [2 ]
Bin Riaz, Irbaz [1 ]
Thai, Hoang [1 ]
Cassese, Salvatore [3 ]
Finn, Aloke [4 ]
Samady, Habib [4 ]
Byrne, Robert A. [3 ]
机构
[1] Univ Arizona, Tucson, AZ USA
[2] Cleveland Clin, Cleveland, OH 44106 USA
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Munich, Germany
[4] Emory Univ, Atlanta, GA 30322 USA
关键词
stents; coronary disease; meta-analysis; DRUG-ELUTING STENTS; THROMBOSIS; RESTENOSIS;
D O I
10.1002/ccd.26374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesWe sought to pool data from all studies with reported strut-level data in human subjects evaluated by optical coherence tomography (OCT) surveillance and to compare the aggregate data of stent strut coverage on a longitudinal temporal timeline from initial implantation for different coronary stent subtypes. BackgroundDelayed strut coverage following drug-eluting stent (DES) implantation is an important contributor to late stent thrombosis (LST). OCT can detect stent strut coverage. MethodsWe conducted a systematic search of published or presented studies reporting OCT stent strut coverage of bare-metal stents (BMS) and DES in PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials to June 2014. Data from 3,515 patients with strut-level data on 731,761 struts were analyzed. ResultsThe temporal kinetics of strut coverage differed according to stent type. The rate of strut coverage, reflected by the calculated regression coefficient, was found to be the highest in BMS, followed by early generation zotarolimus-eluting stent, everolimus-eluting stent, newer-generation zotarolimus-eluting stent, paclitaxel-eluting stent, and sirolimus-eluting stent (p<0.0001). ConclusionsAggregate rates of stent strut coverage assessed by OCT surveillance differed according to stent type. The clinical implications of these differences require further study but may underlie the differences in rates of stent thrombosis observed in clinical trials with different stent types. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1083 / 1093
页数:11
相关论文
共 50 条
  • [21] Characteristics of optical coherence tomography in patients with iron deficiency anemia : a systematic review and meta-analysis
    Ghasemi, Mohammadreza
    Ghasemi, Alireza
    Khorasani, Saleheh
    Zare, Sama
    Sazgar, Amir Keyvan
    Nikkhah, Homayoun
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [22] Diagnostic accuracy of optical coherence tomography angiography for choroidal neovascularization: a systematic review and meta-analysis
    Wang, Rui
    Liang, Zhenzhen
    Liu, Xin
    BMC OPHTHALMOLOGY, 2019, 19 (1)
  • [23] Diagnostic accuracy of optical coherence tomography angiography for choroidal neovascularization: a systematic review and meta-analysis
    Rui Wang
    Zhenzhen Liang
    Xin Liu
    BMC Ophthalmology, 19
  • [24] Evaluation of retinal microvascular features in patients with amblyopia based on optical coherence tomography angiography: a systematic review and Meta-analysis
    Feng, Kangchun
    Yu, Xuelin
    Jingyue, Zhang
    Yang, Zhenghua
    Xing, Chen
    Kang, Gangjing
    OPHTHALMIC RESEARCH, 2023, : 39 - 47
  • [25] Neointimal coverage and stent strut apposition six months after implantation of a paclitaxel eluting stent in acute coronary syndromes: An optical coherence tomography study
    Davlouros, Periklis A.
    Nikokiris, George
    Karantalis, Vasileios
    Mavronasiou, Eleni
    Xanthopoulou, Ioanna
    Damelou, Anastasia
    Tsigkas, Grigorios
    Alexopoulos, Dimitrios
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 151 (02) : 155 - 159
  • [26] The Relationship Between Post-Stent Strut Apposition and Follow-Up Strut Coverage Assessed by a Contour Plot Optical Coherence Tomography Analysis
    Kim, Jung-Sun
    Ha, Jinyong
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (06) : 641 - 651
  • [27] Incidence of coronary drug-eluting stent fracture: A systematic review and meta-analysis
    Chen, Yang
    Li, Dandan
    Liao, Yanhui
    Yao, Xiongda
    Ruan, Yuehua
    Zou, Kai
    Liao, Hanhui
    Ding, Jingwen
    Qin, Hao
    Yu, Zuozhong
    Zhao, Yuanbin
    Hu, Longlong
    Yang, Renqiang
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [28] Accuracy of Optical Coherence Tomography in the Evaluation of Neointimal Coverage After Stent Implantation
    Murata, Akira
    Wallace-Bradley, David
    Tellez, Armando
    Alviar, Carlos
    Aboodi, Michael
    Sheehy, Alexander
    Coleman, Leslie
    Perkins, Laura
    Nakazawa, Gaku
    Mintz, Gary
    Kaluza, Greg L.
    Virmani, Renu
    Granada, Juan F.
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (01) : 76 - 84
  • [29] Associations of refractive errors and retinal changes measured by optical coherence tomography: A systematic review and meta-analysis
    Salehi, Mohammad Amin
    Nowroozi, Ali
    Gouravani, Mahdi
    Mohammadi, Soheil
    Arevalo, J. Fernando
    SURVEY OF OPHTHALMOLOGY, 2022, 67 (02) : 591 - 607
  • [30] The relationship between coronary stent strut thickness and the incidences of clinical outcomes after drug-eluting stent implantation: A systematic review and meta-regression analysis
    Saito, Akira
    Dai, Zhehao
    Ono, Masafumi
    Kanie, Takayoshi
    Takaoka, Yoshimitsu
    Mizuno, Atsushi
    Komiyama, Nobuyuki
    Asano, Taku
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 575 - 582