Temporal Trends in Strut-Level Optical Coherence Tomography Evaluation of Coronary Stent Coverage: A Systematic Review and Meta-Analysis

被引:12
|
作者
Lee, Kwan S. [1 ]
Lee, Justin Z. [1 ]
Hsu, Chiu-Hsieh [1 ]
Husnain, Muhammad [1 ]
Riaz, Haris [2 ]
Bin Riaz, Irbaz [1 ]
Thai, Hoang [1 ]
Cassese, Salvatore [3 ]
Finn, Aloke [4 ]
Samady, Habib [4 ]
Byrne, Robert A. [3 ]
机构
[1] Univ Arizona, Tucson, AZ USA
[2] Cleveland Clin, Cleveland, OH 44106 USA
[3] Tech Univ Munich, Deutsch Herzzentrum Munchen, Munich, Germany
[4] Emory Univ, Atlanta, GA 30322 USA
关键词
stents; coronary disease; meta-analysis; DRUG-ELUTING STENTS; THROMBOSIS; RESTENOSIS;
D O I
10.1002/ccd.26374
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectivesWe sought to pool data from all studies with reported strut-level data in human subjects evaluated by optical coherence tomography (OCT) surveillance and to compare the aggregate data of stent strut coverage on a longitudinal temporal timeline from initial implantation for different coronary stent subtypes. BackgroundDelayed strut coverage following drug-eluting stent (DES) implantation is an important contributor to late stent thrombosis (LST). OCT can detect stent strut coverage. MethodsWe conducted a systematic search of published or presented studies reporting OCT stent strut coverage of bare-metal stents (BMS) and DES in PubMed, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials to June 2014. Data from 3,515 patients with strut-level data on 731,761 struts were analyzed. ResultsThe temporal kinetics of strut coverage differed according to stent type. The rate of strut coverage, reflected by the calculated regression coefficient, was found to be the highest in BMS, followed by early generation zotarolimus-eluting stent, everolimus-eluting stent, newer-generation zotarolimus-eluting stent, paclitaxel-eluting stent, and sirolimus-eluting stent (p<0.0001). ConclusionsAggregate rates of stent strut coverage assessed by OCT surveillance differed according to stent type. The clinical implications of these differences require further study but may underlie the differences in rates of stent thrombosis observed in clinical trials with different stent types. (c) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1083 / 1093
页数:11
相关论文
共 50 条
  • [1] Optical coherence tomography (OCT) strut-level analysis of drug-eluting stents (DES) in human coronary bifurcations
    Kyono, Hiroyuki
    Guagliumi, Giulio
    Sirbu, Vasile
    Rosenthal, Noah
    Tahara, Satoko
    Musumeci, Giuseppe
    Trivisonno, Antonio
    Bezerra, Hiram G.
    Costa, Marco A.
    EUROINTERVENTION, 2010, 6 (01) : 69 - 77
  • [2] A Randomized Optical Coherence Tomography Study of Coronary Stent Strut Coverage and Luminal Protrusion With Rapamycin-Eluting Stents
    Moore, Philip
    Barlis, Peter
    Spiro, Jonathan
    Ghimire, Gopal
    Roughton, Michael
    Di Mario, Carlo
    Wallis, William
    Ilsley, Charles
    Mitchell, Andrew
    Mason, Mark
    Kharbanda, Rajesh
    Vincent, Peter
    Sherwin, Spencer
    Dalby, Miles
    JACC-CARDIOVASCULAR INTERVENTIONS, 2009, 2 (05) : 437 - 444
  • [3] Quantitative analysis of intracoronary optical coherence tomography measurements of stent strut apposition and tissue coverage
    Barlis, Peter
    Dimopoulos, Konstantinos
    Tanigawa, Jun
    Dzielicka, Ewa
    Ferrante, Giuseppe
    Del Furia, Francesca
    Di Mario, Carlo
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 141 (02) : 151 - 156
  • [4] Optical coherence tomography evaluation of intermediate-term healing of different stent types: systemic review and meta-analysis
    Iannaccone, Mario
    D'Ascenzo, Fabrizio
    Templin, Christian
    Omede, Pierluigi
    Montefusco, Antonio
    Guagliumi, Giulio
    Serruys, Patrick W.
    Di Mario, Carlo
    Kochman, Janusz
    Quadri, Giorgio
    Biondi-Zoccai, Giuseppe
    Luescher, Thomas F.
    Moretti, Claudio
    D'amico, Maurizio
    Gaita, Fiorenzo
    Stone, Gregg W.
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (02) : 159 - 166
  • [5] Impact of age on Stent Strut Coverage and Neointimal Remodeling as assessed by Optical Coherence Tomography
    Han, Zhigang
    Feng, Linxing
    Du, Hongwei
    Sun, Zhao
    Hu, Sining
    Dai, Jiannan
    Sun, Meng
    Xing, Lei
    Hou, Jingbo
    Zhang, Shaosong
    Yu, Bo
    MEDICINE, 2015, 94 (50)
  • [6] Strut apposition after coronary stent implantation visualised with optical coherence tomography
    Radu, Maria
    Jorgensen, Erik
    Kelbaek, Henning
    Helqvist, Steffen
    Skovgaard, Lene
    Saunamaki, Karl
    EUROINTERVENTION, 2010, 6 (01) : 86 - 93
  • [7] Difference in neointimal coverage at chronic stage between bare metal stent and sirolimus-eluting stent evaluated at stent-strut level by optical coherence tomography
    Ikuta, Shinichiro
    Kobuke, Kazuhiro
    Iwanaga, Yoshitaka
    Nakauchi, Yoshifumi
    Yamaji, Kenji
    Miyazaki, Shunichi
    HEART AND VESSELS, 2014, 29 (03) : 320 - 327
  • [8] Coronary Angiography, Intravascular Ultrasound, and Optical Coherence Tomography for Guiding of Percutaneous Coronary Intervention: A Systematic Review and Network Meta-Analysis
    Giacoppo, Daniele
    Laudani, Claudio
    Occhipinti, Giovanni
    Spagnolo, Marco
    Greco, Antonio
    Rochira, Carla
    Agnello, Federica
    Landolina, Davide
    Mauro, Maria Sara
    Finocchiaro, Simone
    Mazzone, Placido Maria
    Ammirabile, Nicola
    Imbesi, Antonino
    Raffo, Carmelo
    Buccheri, Sergio
    Capodanno, Davide
    CIRCULATION, 2024, 149 (14) : 1065 - 1086
  • [9] Initial findings of impact of strut width on stent coverage and apposition of sirolimus-eluting stents assessed by optical coherence tomography
    Nakatani, Shimpei
    Nishino, Masami
    Taniike, Masayuki
    Makino, Nobuhiko
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Tanouchi, Jun
    Yamada, Yoshio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 776 - 781
  • [10] Diagnostic accuracy of optical coherence tomography for bladder cancer: A systematic review and meta-analysis
    Xiong, Yi-Quan
    Tan, Jing
    Liv, Yan-Mei
    Li, Yong-Zhi
    You, Fang-Fei
    Zhang, Min-Yi
    Chen, Qing
    Zou, Kang
    Sun, Xin
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2019, 27 : 298 - 304