Validation of a portable system for spatial-temporal gait parameters based on a single inertial measurement unit and a mobile application

被引:6
作者
Aqueveque, Pablo [1 ]
Gomez, Britam [1 ]
Saavedra, Francisco [1 ]
Canales, Cristian [2 ]
Contreras, Simon [2 ]
Ortega-Bastidas, Paulina [3 ]
Cano-de-la-Cuerda, Roberto [4 ]
机构
[1] Univ Concepcion, Elect Engn Dept, Fac Engn, Edmundo Larenas 219, Concepcion 4030000, Biobio, Chile
[2] Univ Concepcion, Mech Engn Dept, Fac Engn, Concepcion, Biobio, Chile
[3] Univ Concepcion, Fac Med, Kinesiol Dept, Concepcion, Biobio, Chile
[4] Univ Rey Juan Carlos, Occupat Therapy, Physiotherapy, Madrid, Spain
关键词
Gait analysis; Spatial-temporal gait parameters; Inertial sensors; ACCELEROMETER; GYROSCOPE;
D O I
10.4081/ejtm.2020.9002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
There is a lack of commercially available low-cost technologies to assess gait clinically in non-controlled environments. As a consequence of this, there has been poor massification of motion measurement technologies that are both objective and reliable in nature. Advances about the study of gait and its interpretation in recent years using inertial sensors have allowed proposing acceptable alternatives for the development of portable and low-cost systems that contribute to people's health in places and institutions that cannot acquire or maintain the operation of commercially available systems. A system based on a custom single Inertial Measurement Unit and a mobile application is proposed. Thus, an investigation is carried out using methodologies and algorithms found in the literature in order to get the main gait events and the spatial-temporal gait parameters. Twenty healthy Chilean subjects were assessed using a motion capture system simultaneously with the proposed tool. The results show that it is possible to estimate temporal gait parameters with slight differences respect gold--standard. We reach maximum mean differences of -2.35 +/- 5.02[step/min] for cadence, 0.03 +/- 0.04[sec] for stride time,0.02 +/- 0.03[sec] for step time, +/- 0.02[sec] for a single support time, 0.01 +/- 0.02[sec] for double support time and 0.01 +/- 0.03[m] for step length. As a result of experimental findings, we propose a new technological tool that can perform gait analysis. Our proposed system is user-friendly, low-cost, and portable. Therefore, we suggest that it could be an attractive technological tool that healthcare professionals could harness to objectively measure gait in environments that are either within the community or controlled. We also suggest that the tool could be used in countries where advanced clinical tools cannot be acquired. Therefore, we propose in this paper that our system is an attractive, alternative system that can be used for gait analysis by health professionals worldwide.
引用
收藏
页码:268 / U136
页数:9
相关论文
共 33 条
  • [1] Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
    Aminian, K
    Najafi, B
    Büla, C
    Leyvraz, PF
    Robert, P
    [J]. JOURNAL OF BIOMECHANICS, 2002, 35 (05) : 689 - 699
  • [2] Temporal feature estimation during walking using miniature accelerometers: an analysis of gait improvement after hip arthroplasty
    Aminian, K
    Rezakhanlou, K
    De Andres, E
    Fritsch, C
    Leyvraz, PF
    Robert, P
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (06) : 686 - 691
  • [3] SINGULARITIES OF EULER AND ROLL-PITCH-YAW REPRESENTATIONS
    ANG, MH
    TOURASSIS, VD
    [J]. IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 1987, 23 (03) : 317 - 324
  • [4] [Anonymous], 2019, BNO055
  • [5] A Systematic Review of Access to Rehabilitation for People with Disabilities in Low- and Middle-Income Countries
    Bright, Tess
    Wallace, Sarah
    Kuper, Hannah
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2018, 15 (10)
  • [6] Quantification of upper body movements during gait in older adults and in those with Parkinson's disease: impact of acceleration realignment methodologies
    Buckley, Christopher
    Galna, Brook
    Rochester, Lynn
    Mazza, Claudia
    [J]. GAIT & POSTURE, 2017, 52 : 265 - 271
  • [7] What is the Best Configuration of Wearable Sensors to Measure Spatiotemporal Gait Parameters in Children with Cerebral Palsy?
    Carcreff, Lena
    Gerber, Corinna N.
    Paraschiv-Ionescu, Anisoara
    De Coulon, Geraldo
    Newman, Christopher J.
    Armand, Stephane
    Aminian, Kamiar
    [J]. SENSORS, 2018, 18 (02):
  • [8] Pedestrian Navigation Based on a Waist-Worn Inertial Sensor
    Carlos Alvarez, Juan
    Alvarez, Diego
    Lopez, Antonio
    Gonzalez, Rafael C.
    [J]. SENSORS, 2012, 12 (08) : 10536 - 10549
  • [9] A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE
    DAVIS, RB
    OUNPUU, S
    TYBURSKI, D
    GAGE, JR
    [J]. HUMAN MOVEMENT SCIENCE, 1991, 10 (05) : 575 - 587
  • [10] A single gyroscope method for spatial gait analysis
    Doheny, Emer P.
    Foran, Timothy G.
    Greene, Barry R.
    [J]. 2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 1300 - 1303