EXPERIMENTAL INVESTIGATION ON INFLUENCE OF INTEGRATED HEAT PUMP IN PERFORMANCE OF DOMESTIC WATER HEATERS

被引:0
作者
Ison, Jarrod [1 ]
Madadnia, Jafar [1 ]
Vakiloroaya, Vahid [1 ]
机构
[1] Univ Technol Sydney, Fac Engn & IT, Broadway, NSW 2007, Australia
来源
PROCEEDINGS OF THE ASME SUMMER HEAT TRANSFER CONFERENCE, 2012, VOL 1 | 2012年
关键词
HOT-WATER;
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Air Sourced Heat pump Hot Water Heaters (ASHPWH) are integrated in buildings as a multitask system to act as both a water heater and air cooler with a lower carbon footprint. The cost effectiveness of the ASHPWH systems relative to the conventional water-heaters is a challenging issue which is researched in this project. A refined heat pump was integrated into a water heater tank and tested using the Australian testing standard AS/NZS 5125. Experiments included measurement of flow rate, temperature and pressure of water, air and refrigerant (R410a) to determine Coefficient of Performance (COP) and cost-effectiveness of the ASHPWH relative to the current 310L-ASHPWH and a standard electric water heater, of similar size. The leaving water location of the condenser was also studied to reduce scalding / to destroy Legionella bacteria, to improve mixing and the delivery of hot water to the storage-tank, to enhance heat transfer stratification, buoyancy, or pumping. the relative position of the water from the storage-tank was varied and coefficient of performance (COP) of the Heat-pump and effectiveness of the ater heater were determined. Experiments included measuring water heater were determined. Experiments included measuring water, air and refrigerants flow-rates and temperatures and power consumed in compressor. This research in progress will recommend on the condition this method is reasonable. The operational cost of 310L was 38% cheaper than the standard electric. The design (claimed) heat pump would operate 52% cheaper than the electric water heater. Carbon tax was not included but it is estimated that carbon footprint of the tested heat pump and the Standard 310L-ASHPWH were lower due to lower consumption of 40% and 33% electricity respectively relative to the electric water heater.
引用
收藏
页码:151 / 155
页数:5
相关论文
共 8 条
  • [1] Simulation of hybrid ground-coupled heat pump with domestic hot water heating systems using HVACSIM
    Cui, Ping
    Yang, Hongxing
    Spitler, Jeffrey D.
    Fang, Zhaohong
    [J]. ENERGY AND BUILDINGS, 2008, 40 (09) : 1731 - 1736
  • [2] Ison Jarrod, 2011, THESIS U TECHNOLOGY
  • [3] Transient thermal behavior of a water heater system driven by a heat pump
    Kim, M
    Kim, MS
    Chung, JD
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (04): : 415 - 421
  • [4] Study on performance of solar assisted air source heat pump systems for hot water production in Hong Kong
    Li, Hong
    Yang, Hongxing
    [J]. APPLIED ENERGY, 2010, 87 (09) : 2818 - 2825
  • [5] Theoretical and experimental analysis of a CO2 heat pump for domestic hot water
    Minetto, Silvia
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (03): : 742 - 751
  • [6] Rheem Australia Pty Ltd, PROJ AZT HEAT PUMP T
  • [7] A new inverter heat pump operated all year round with domestic hot water
    Shao, SQ
    Shi, WX
    Li, XT
    Ma, J
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2004, 45 (13-14) : 2255 - 2268
  • [8] unfccc, Global Warming Potentials (IPCC Second Assessment Report)