Microwaves Doppler Transducer for Noninvasive Monitoring of the Cardiorespiratory Activity

被引:3
作者
Baltag, O. [1 ]
机构
[1] Gr T Popa Univ Med & Pharm, Iasi, Romania
关键词
Cardiorespiratory activity; Doppler frequency; microwave; noninvasive monitoring;
D O I
10.1109/TMAG.2008.2003125
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The cardiorespiratory monitoring is interesting in a number of situations, the most important being the case of intensive care patients, the patients that were given sedatives, which can result in diminished reflexes, for newborn babies, etc. At present, the cardiorespiratory activity is monitored by the direct contact of the patient with the respiration sensors using the tensometric marks, capacitive sensors of motion, or the electrodes that detects the heart bioelectric activity. The proposed method refers to noncontact detection of the cardiorespiratory activity, by means of a microwaves Doppler motion detector. Another problem is to identify in the complex Doppler signal, the two components: the signal due to the cardiac activity and the signals produced by the respiration activity.
引用
收藏
页码:4484 / 4487
页数:4
相关论文
共 13 条
[1]  
BALTAG O, 2004, SENSORS BIOSENSORS T
[2]   Unconstrained detection of respiration rhythm and pulse rate with one under-pillow sensor during sleep [J].
Chen, W ;
Zhu, X ;
Nemoto, T ;
Kanemitsu, Y ;
Kitamura, K ;
Yamakoshi, K .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) :306-312
[3]  
DARNALL R, 1977, PEDIATRICS, V100, P795
[4]   Measurement of thoracoabdominal asynchrony: importance of sensor sensitivity to cross section deformations [J].
De Groote, A ;
Verbandt, Y ;
Paiva, M ;
Mathys, P .
JOURNAL OF APPLIED PHYSIOLOGY, 2000, 88 (04) :1295-1302
[5]   Critical review of non-invasive respiratory monitoring in medical care [J].
Folke, M ;
Cernerud, L ;
Ekström, M ;
Hök, B .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (04) :377-383
[6]   Comparative provocation test of respiratory monitoring methods [J].
Folke M. ;
Granstedt F. ;
Hök B. ;
Scheer H. .
Journal of Clinical Monitoring and Computing, 2002, 17 (2) :97-103
[7]  
Harvey A.F., 1963, Microwave Engineering ~
[8]   Cardiopulmonary monitoring by textile electrodes without subject-awareness of being monitored [J].
Ishijima, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (06) :685-690
[9]   Inductive plethysmography components analysis and improved non-invasive postoperative apnoea monitoring [J].
Millard, RK .
PHYSIOLOGICAL MEASUREMENT, 1999, 20 (02) :175-186
[10]   Unconstrained cardiorespiratory and body movement monitoring system for home care [J].
Niizeki, K ;
Nishidate, I ;
Uchida, K ;
Kuwahara, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (06) :716-724