Examination of Knee Joint Moments on the Function of Knee-Ankle-Foot Orthoses During Walking

被引:8
作者
Andrysek, Jan [1 ,2 ]
Klejman, Susan [1 ]
Kooy, John [1 ,3 ]
机构
[1] Holland Bloorview Kids Rehabil Hosp, Bloorview Res Inst, Toronto, ON, Canada
[2] Univ Toronto, Inst Biomat & Biomed Engn, Toronto, ON, Canada
[3] Holland Bloorview Kids Rehabil Hosp, Clin Technol Dept, Toronto, ON, Canada
基金
加拿大健康研究院;
关键词
gait; lower limb; stance phase control; rehabilitation; stance control orthosis; GAIT; PARAMETERS; LOADS;
D O I
10.1123/jab.29.4.474
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this study was to investigate clinically relevant biomechanical conditions relating to the setup and alignment of knee-ankle-foot orthoses and the influence of these conditions on knee extension moments and orthotic stance control during gait. Knee moments were collected using an instrumented gait laboratory and concurrently a load transducer embedded at the knee-ankle-foot orthosis knee joint of four individuals with poliomyelitis. We found that knee extension Moments were not typically produced in late stance-phase of gait. Adding a dorsiflexion stop at the orthotic ankle significantly decreased the knee flexion moments in late stance-phase, while slightly flexing the knee in stance-phase had a variable effect. The findings suggest that where users of orthoses have problems initiating swing-phase flexion with stance control orthoses, an ankle dorsiflexion stop may be used to enhance function. Furthermore, the use of stance control knee joints that lock while under flexion may contribute to more inconsistent unlocking of the stance control orthosis during gait.
引用
收藏
页码:474 / 480
页数:7
相关论文
共 26 条
[1]   A method to measure the accuracy of loads in knee-ankle-foot orthoses using conventional gait analysis, applied to persons with poliomyelitis [J].
Andrysek, Jan ;
Redekop, Susan ;
Matsui, Naomi C. ;
Kooy, John ;
Hubbard, Sheila .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2008, 89 (07) :1372-1379
[2]  
[Anonymous], 2005, SCOTT ORTH SERV REV
[3]   Loads on the uprights of a knee-ankle-foot orthosis [J].
Bernhardt, K. A. ;
Kaufman, K. R. .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2011, 35 (01) :106-112
[4]  
Bernhardt KA, 2010, P 13 WORLD C INT SOC, P16
[5]   The effect of stance control orthoses on gait characteristics and energy expenditure in knee-ankle-foot orthosis users [J].
Davis, Priya Chantal ;
Bach, Timothy Michael ;
Pereira, Darren Mark .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2010, 34 (02) :206-215
[6]  
DiBello TV., 2007, ORTHOTICS PROSTHET, P237
[7]   Gait evaluation of an automatic stance-control knee orthosis in a patient with postpoliomyelitis [J].
Hebert, JS ;
Liggins, AB .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2005, 86 (08) :1676-1680
[8]   Biomechanical effect of electromechanical knee-ankle-foot-orthosis on knee joint control in patients with poliomyelitis [J].
Hwang, Sungjae ;
Kang, Sungjae ;
Cho, Kanghee ;
Kim, Youngho .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (06) :541-549
[9]   Gait of stance control orthosis users: The Dynamic Knee Brace System [J].
Irby, SE ;
Bernhardt, KA ;
Kaufman, KR .
PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2005, 29 (03) :269-282
[10]  
Jerrell ML, 2003, O P BUSINESS NEW OCT