Liquid chromatography/tandem mass spectrometry (highly selective selected reaction monitoring) for the analysis of isopropylthioxanthone in packaged food

被引:32
作者
Gallart-Ayala, H. [1 ]
Moyano, E. [1 ]
Galceran, M. T. [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
ITX; LC-MS/MS; H-SRM; Food;
D O I
10.1016/j.chroma.2008.08.104
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isopropylthioxanthone (ITX), usually applied as a mixture of 2- and 4-isomers, is a common photo-initiator in UV inks used in paper- or plastic-based packaging materials. In this work a pentafluorophenylpropyl column (HS F5) has been used to achieve the chromatographic separation of the two isomers. A gradient elution with acetonitrile and a 25 mM formic acid-ammonium formate at pH 3.75 are required to provide an R-s of 1.3 between the two compounds. The fragmentation pattern of ITX was studied using two mass analyzers, an ion trap (IT) (multi-stage fragmentation) and a triple quadrupole mass analyzer of hyperbolic rods (accurate mass (AM) measurement). The protonated molecule [M+H](+) observed in the mass spectrometry (MS) spectrum lost an isopropyl group, [M+H-C3H6](+). Later, this ion fragmented, yielding the radical ion [M+H-C3H6-CHO](center dot+). The elemental composition of these product ions was confirmed by AM measurement. Electrospray ionization (ESI) was used as an ionization source to couple liquid chromatography (LC) to MS. Instrumental quality parameters of three acquisition modes provided by the triple quadrupole mass analyzer were studied and good run-to-run precision (relative standard deviation, RSD, lower than 10%) and limits of detection (LODs) down to 0.8 pg injected in the LC-MS/MS system were obtained. Finally the LC-MS/MS method using H-SRM Q1 acquisition mode was used to analyze 2- and 4-ITX in a range of food samples. The use of highly selective selected reaction monitoring (H-SRM on Q1) resulted in improved selectivity without sensitivity loss. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:182 / 188
页数:7
相关论文
共 12 条
[1]   A packaging contaminant: Isopropylthioxanthone (ITX) in dairy products [J].
Benetti, C. ;
Angeletti, R. ;
Binato, G. ;
Biancardi, A. ;
Biamotto, G. .
ANALYTICA CHIMICA ACTA, 2008, 617 (1-2) :132-138
[2]  
*EFSA, 2005, EFSA J, V293, P1, DOI DOI 10.2903/J.EFSA.2005.293
[3]   Determination of 2-isopropyl thioxanthone and 2-ethylhexyl-4-dimethylaminobenzoate in milk:: comparison of gas and liquid chromatography with mass spectrometry [J].
Gil-Vergara, Ana ;
Blasco, Cristina ;
Pico, Yolanda .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (02) :605-617
[4]  
Morlock G., 2006, CLB CHEM LABOR BIOTE, V57, P342
[5]   New coupling of planar chromatography with direct analysis in real time mass spectrometry [J].
Morlock, Gertrud ;
Ueda, Yoshihisa .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1143 (1-2) :243-251
[6]   Determination of isopropylthioxanthone (ITX) in milk, yoghurt and fat by HPTLC-FLD, HPTLC-ESI/MS and HPTLC-DART/MS [J].
Morlock, Gertrud ;
Schwack, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (03) :586-595
[7]   Migration tests for substrates printed with UV ink systems in aqueous simulants [J].
Papilloud, S ;
Baudraz, D .
PROGRESS IN ORGANIC COATINGS, 2002, 45 (2-3) :231-237
[8]   Analysis of food packaging UV inks for chemicals with potential to migrate into food simulants [J].
Papilloud, S ;
Baudraz, D .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (02) :168-175
[9]   2-Isopropylthioxanthone (2-ITX) in food and food packaging materials on the German market [J].
Rothenbacher, T. ;
Baumann, M. ;
Fuegel, D. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2007, 24 (04) :438-444
[10]   Determination of ink photoinitiators in packaged beverages by gas chromatography-mass spectrometry and liquid chromatography-mass spectrometry [J].
Sagratini, Gianni ;
Caprioli, Giovanni ;
Cristalli, Gloria ;
Giardina, Dario ;
Ricciutelli, Massimo ;
Volpini, Rosaria ;
Zuo, Yanting ;
Vittori, Sauro .
JOURNAL OF CHROMATOGRAPHY A, 2008, 1194 (02) :213-220