Seismic performance evaluation of RC columns reinforced by GFRP composite sheets with clip connectors

被引:18
作者
Kim, Jinsup [1 ]
Kwon, Minho [2 ]
Jung, Wooyoung [3 ]
Limkatanyu, Suchart [4 ]
机构
[1] Gyeongsang Natl Univ, Dept Civil Engn, Jinju, South Korea
[2] Gyeongsang Natl Univ, ERI, Dept Civil Engn, Jinju, South Korea
[3] Gangneung Wonju Natl Univ, Dept Civil Engn, Kangnung, South Korea
[4] Prince Songkla Univ, Fac Engn, Dept Civil Engn, Hat Yai, Thailand
关键词
RC-column; FRP composite; Ductility; Seismic retrofitting; Glass fiber; RETROFIT; STRENGTH; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2013.02.023
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper performs experimental and numerical studies on the seismic performance of non-seismically detailed RC columns retrofitted with the proposed GFRP strengthening device. The primary goal of this study was to improve the shear strength and ductility of weak-in-shear columns. It was proposed a strengthening device that was consisted of a prefabricated GFRP composite sheet and aluminum clip connectors. This device was designed to speed up the installation time and to minimize the disturbance to adjacent walls and non-structural components. Efficiency of the proposed GFRP strengthening installation is evaluated through a series of experiments on non-strengthened and strengthened 3:4 scale RC column specimens. Comparisons between experimental results of the non-strengthened and strengthened column specimens are conducted in terms of column strength, ultimate displacement ductility, amount of hysteretic dissipated energy, and column shear behavior. So, comparisons focused on ultimate displacement ductility and hysteretic dissipated energy. A series of finite element analyses are performed to confirm the efficiency of the proposed GFRP strengthening device. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:563 / 574
页数:12
相关论文
共 21 条
  • [1] ABAQUS, 2011, ABAQUS THEOR US MAN
  • [2] ACI Manual of Concrete Practice, 2012, 440 ACI 6, P25
  • [3] American Concrete Institute, 2012, 318 ACI
  • [4] [Anonymous], ACI STRUCT J
  • [5] ASTM, 2017, D3039D3039M17 ASTM, DOI DOI 10.1520/D3039_D3039M-17
  • [6] Comparative assessment of seismic rehabilitation techniques on a full scale 3-story RC moment frame structure
    Di Ludovico, M.
    Balsamo, A.
    Prota, A.
    Manfredi, G.
    [J]. STRUCTURAL ENGINEERING AND MECHANICS, 2008, 28 (06) : 727 - 747
  • [7] Seismic Resistance of RC Bent Caps in Elevated Mass Transit Structures
    Kwon, Minho
    Shing, P. Benson
    Mallare, Chip
    Restrepo, Jose
    [J]. EARTHQUAKE SPECTRA, 2011, 27 (01) : 67 - 88
  • [8] Plastic-damage model for cyclic loading of concrete structures
    Lee, JH
    Fenves, GL
    [J]. JOURNAL OF ENGINEERING MECHANICS-ASCE, 1998, 124 (08): : 892 - 900
  • [9] A PLASTIC-DAMAGE MODEL FOR CONCRETE
    LUBLINER, J
    OLIVER, J
    OLLER, S
    ONATE, E
    [J]. INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 1989, 25 (03) : 299 - 326
  • [10] Matsuda T, 1990, 1 US JAP WORKSH SEIS