摘要
In the present work, a simple and effective method based on magnetic separation has been developed for the extraction of monocyclic aromatic amines in water and urine samples using poly(paraphenylenediamine) modified with Fe3O4 nanoparticles (PpPD/Fe3O4) as an adsorbent. The chemical structures of the sorbent were characterized by field emission scanning electron microscopy (FESEM) and Fourier transform infrared spectrophotometer (FT-IR). Various parameters affecting on the extraction efficiency of desired analytes, such as pH of solution, desorption conditions, extraction time, salt effect and amount of adsorbent have been investigated and optimized. The obtained optimal conditions were: sample pH, 6; amount of sorbent, 20 mg; sorption time, 2 min; elution solvent and its volume, dichloromethane and chloroform (3:1 v/v), 250 mu L; elution time, 30s and without addition of NaCI. Under the optimum conditions, detection limits in the range of 0,007-0.01 ngmL(-1) were obtained by gas chromatography-flame ionization detector (GC-FID). The calibration curves were linear in the range 0.05-100 ng mL(-1) with a correlation coefficient better than 0.9953. In addition, a satisfactory reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations (RSDs) less than 5.9 and 7.3%, respectively. The proposed procedure has been successfully applied to the determination of target analytes in water and urine samples. The results demonstrated that the developed method is simple, inexpensive, accurate and remarkably free from interference effects. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 24 条
[1]   Magnetic solids in analytical chemistry: A review [J].
Aguilar-Arteaga, K. ;
Rodriguez, J. A. ;
Barrado, E. .
ANALYTICA CHIMICA ACTA, 2010, 674 (02) :157-165
[2]   Novel proton-type ionic liquid doped polyaniline for the headspace solid-phase microextraction of amines [J].
Ai, Youhong ;
Zhao, Faqiong ;
Zeng, Baizhao .
ANALYTICA CHIMICA ACTA, 2015, 880 :60-66
[3]  
[Anonymous], 2009, IR SUBST LIST
[4]   Conductive polymer-based microextraction methods: A review [J].
Bagheri, Habib ;
Ayazi, Zahra ;
Naderi, Mehrnoush .
ANALYTICA CHIMICA ACTA, 2013, 767 :1-13
[5]   Emulsion polymerization mechanisms and kinetics [J].
Chern, C. S. .
PROGRESS IN POLYMER SCIENCE, 2006, 31 (05) :443-486
[6]   Magnetic materials as sorbents for metal/metalloid preconcentration and/or separation. A review [J].
Giakisikli, Georgia ;
Anthemidis, Aristidis N. .
ANALYTICA CHIMICA ACTA, 2013, 789 :1-16
[7]   Determination of UV-filter residues in bathing waters by liquid chromatography UV-diode array and gas chromatography mass spectrometry after micelle mediated extraction-solvent back extraction [J].
Giokas, DL ;
Sakkas, VA ;
Albanis, TA ;
Lampropoulou, DA .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1077 (01) :19-27
[8]  
Gold L.S., 1997, HDB CARCINOGENIC POT
[9]   Detection of carcinogenic aromatic amines in the urine of non-smokers [J].
Grimmer, G ;
Dettbarn, G ;
Seidel, A ;
Jacob, J .
SCIENCE OF THE TOTAL ENVIRONMENT, 2000, 247 (01) :81-90
[10]   Magnetic separation techniques in sample preparation for biological analysis: A review [J].
He, Jincan ;
Huang, Meiying ;
Wang, Dongmei ;
Zhang, Zhuomin ;
Li, Gongke .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 101 :84-101