Sleep Quality and Sleepiness in Persons with Implantable Cardioverter Defibrillators: Outcome from a Clinical Randomized Longitudinal Trial

被引:16
作者
Berg, Selina Kikkenborg [1 ]
Higgins, Melinda [2 ]
Reilly, Carolyn M. [2 ]
Langberg, Jonathan J. [3 ]
Dunbar, Sandra B. [2 ]
机构
[1] Rigshosp, Ctr Heart, DK-2100 Copenhagen, Denmark
[2] Emory Univ, Nell Hodgson Woodruff Sch Nursing, Atlanta, GA 30322 USA
[3] Emory Univ, Sch Med, Dept Med, Div Cardiol, Atlanta, GA USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2012年 / 35卷 / 04期
关键词
defibrillation-ICD; clinical trials; ARTERY-BYPASS-SURGERY; OF-LIFE ASSESSMENT; HEART-FAILURE; VENTRICULAR-ARRHYTHMIAS; TELEPHONE INTERVENTION; BREATHING DISORDERS; CARDIAC-SURGERY; HEALTH; ASSOCIATION; SYMPTOMS;
D O I
10.1111/j.1540-8159.2011.03328.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Patients receiving an implantable cardioverter defibrillator (ICD) report various types and degree of sleep disruptions, but little is known regarding their characteristics, duration, and associated factors. The purposes of this study were: (1) to describe the effect of a psychoeducational intervention on sleep quality and daytime sleepiness, (2) to describe patterns of sleep over time, and (3) to identify predictors of poor sleep in an ICD population. Methods: A randomized longitudinal intervention trial was designed to test the effects of a psychoeducational intervention, which included a sleep education and counseling session in patients receiving their initial ICD. Patients (n= 236; 75% men; mean age 58.4 [+/- 11.2] from the PsychoEducationAl Intervention for ICD PatiEnts (PEACE) trial comprised the study population. Variables related to sleep were measured by the Pittsburgh Sleep Quality Inventory (PSQI) and Epworth Sleepiness Scale (ESS). Results: No psychoeducational intervention effects on sleep outcomes were observed. However, 67.2% of the patients reported poor sleep quality at baseline, and 56.8% had low sleep quality at 6 months based on PSQI scores > 5; one-third (32.6%) were excessively sleepy based on ESS scores = 10 at 6 months. Anxiety, depression, physical function, pain intensity, and pain severity were all highly correlated to each other across time. Female gender was a significant covariate for the PSQI. New York Heart Association (NYHA) class was a significant covariate for sleepiness (Epworth). Conclusions: Low sleep quality and daytime sleepiness are found at time of insertion and over time in patients with ICD. Female gender, higher NYHA class, as well as two latent factors encompassing increased anxiety, depressive symptoms, and decreased physical function and increased pain, were significant predictors of poor sleep quality and sleepiness over time. These data help identify those at higher risk for sleep problems after ICD. (PACE 2012; 35: 431-443)
引用
收藏
页码:431 / 443
页数:13
相关论文
共 56 条
[1]  
[Anonymous], 1996, SAN ANTONIO TX PSYCH
[2]  
[Anonymous], 1983, STATE TRAIT ANXIETY
[3]   The association of sleep-disordered breathing and sleep symptoms with quality of life in the sleep heart health study [J].
Baldwin, CM ;
Griffith, KA ;
Nieto, FJ ;
O'Connor, GT ;
Walsleben, JA ;
Redline, S .
SLEEP, 2001, 24 (01) :96-105
[4]  
Brostrom Anders, 2004, J Cardiovasc Nurs, V19, P234
[5]   THE PITTSBURGH SLEEP QUALITY INDEX - A NEW INSTRUMENT FOR PSYCHIATRIC PRACTICE AND RESEARCH [J].
BUYSSE, DJ ;
REYNOLDS, CF ;
MONK, TH ;
BERMAN, SR ;
KUPFER, DJ .
PSYCHIATRY RESEARCH, 1989, 28 (02) :193-213
[6]  
Cleeland C S, 1985, Semin Oncol Nurs, V1, P87, DOI 10.1016/S0749-2081(85)80041-3
[7]   Comparison of Actigraphic and Subjective Measures of Sleep in Implantable Cardioverter Defibrillator and Coronary Artery Disease Patients [J].
Cross, Natalie J. ;
McCrae, Christina S. ;
Smith, Karen M. ;
Conti, Jamie B. ;
Sears, Samuel F. .
CLINICAL CARDIOLOGY, 2010, 33 (12) :753-759
[8]   Long-term outcomes of a telephone intervention after an ICD [J].
Dougherty, CM ;
Thompson, EA ;
Lewis, FM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (11) :1157-1167
[9]   Short-term efficacy of a telephone intervention by expert nurses after an implantable cardioverter defibrillator [J].
Dougherty, CM ;
Lewis, FM ;
Thompson, EA ;
Baer, JD ;
Kim, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2004, 27 (12) :1594-1602
[10]  
Dunbar S B, 1999, Depress Anxiety, V9, P163, DOI 10.1002/(SICI)1520-6394(1999)9:4<163::AID-DA3>3.0.CO