Indoor and outdoor air quality assessment of four wastewater treatment plants

被引:21
作者
Lee, JA
Johnson, JC
Reynolds, SJ
Thorne, PS
O'Shaughnessy, PT
机构
[1] Univ Iowa, Dept Environm & Occupat Hlth, Iowa City, IA 52242 USA
[2] Iowa Dept Publ Hlth, Des Moines, IA USA
[3] Colorado State Univ, Dept Environm & Radiol Hlth Sci, Ft Collins, CO 80523 USA
关键词
endotoxin; hydrogen sulfide; wastewater treatment;
D O I
10.1080/15459620500455380
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The study assessed the air quality of four wastewater treatment plants (WWTPs) by monitoring levels of hydrogen sulfide (H2S) and endotoxin. Samples were taken over a 1-year period (2001-2002). The unit operations at each WWTP were categorized as: (a) grit removal, (b) primary clarification, (c) biological treatment, (d) secondary clarification, (e) sludge dewatering, and (f) digestion. Temperature and humidity were monitored simultaneously, whereas airborne H2S and endotoxin were monitored at each of the six unit operations in each plant. Carbonaceous biochemical oxygen demand (CBOD) and total incoming flow of the day of visit were also recorded. The geometric means of H2S concentration were less than 1 ppm and endotoxin ranged from 6-1247 EU/m(3). A mixed model analysis of covariance (ANCOVA) was used for the statistical analysis. While temperature was not associated with the levels of both contaminants, humidity was influential on the level of H2S (p < 0.01) but not of endotoxin. CBOD did not affect the levels of either contaminant; however incoming flows showed an association with the levels of H2S (p < 0.05). The concentrations of H2S in the six unit operations were statistically different, whereas endotoxin did not show any differences in concentrations between units. Individual comparisons proved that concentrations of H2S in the grit removal and sludge dewatering unit operations were statistically higher than the other operations. Overall, the concentrations of H2S varied depending on total incoming flow, humidity, and different unit operations. This trend was not observed for endotoxin. The results showed that the factors analyzed affected concentrations of H2S and endotoxin differently. Therefore, different control methods for endotoxin and H2S need to be considered to effectively reduce their concentrations at WWTPs.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 16 条
  • [1] Astrakianakis G, 1998, AM IND HYG ASSOC J, V59, P694, DOI 10.1202/0002-8894(1998)059<0694:IHAOAS>2.0.CO
  • [2] 2
  • [3] Evaluation of the environmental impact of microbial aerosols generated by wastewater treatment plants utilizing different aeration systems
    Brandi, G
    Sisti, M
    Amagliani, G
    [J]. JOURNAL OF APPLIED MICROBIOLOGY, 2000, 88 (05) : 845 - 852
  • [4] GALTONDE UB, 1987, BMJ-BRIT MED J, V294, P614
  • [5] HEEDERIK D, 1990, ANN AGR ENV MED, V4, P17
  • [6] Exposure to reduced sulfur gases impairs neurobehavioral function
    Kilburn, KH
    [J]. SOUTHERN MEDICAL JOURNAL, 1997, 90 (10) : 997 - 1006
  • [7] RELATIONSHIP BETWEEN BACTERIAL COUNTS AND ENDOTOXIN CONCENTRATIONS IN THE AIR OF WASTE-WATER TREATMENT PLANTS
    LAITINEN, S
    NEVALAINEN, A
    KOTIMAA, M
    LIESIVUORI, J
    MARTIKAINEN, PJ
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1992, 58 (11) : 3774 - 3776
  • [8] WORKERS EXPOSURE TO AIRBORNE BACTERIA AND ENDOTOXINS AT INDUSTRIAL WASTE-WATER TREATMENT PLANTS
    LAITINEN, S
    KANGAS, J
    KOTIMAA, M
    LIESIVUORI, J
    MARTIKAINEN, PJ
    NEVALAINEN, A
    SARANTILA, R
    HUSMAN, K
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1994, 55 (11): : 1055 - 1060
  • [9] AIRBORNE ENDOTOXIN CONCENTRATIONS IN DIFFERENT WORK CONDITIONS
    LIESIVUORI, J
    KOTIMAA, M
    LAITINEN, S
    LOUHELAINEN, K
    PONNI, J
    SARANTILA, R
    HUSMAN, K
    [J]. AMERICAN JOURNAL OF INDUSTRIAL MEDICINE, 1994, 25 (01) : 123 - 124
  • [10] LUNDHOLM M, 1983, BRIT J IND MED, V40, P325