Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography

被引:6
作者
Li, Shan [1 ]
Gai, Luyue [2 ]
Yang, Tingshu [1 ]
Zhang, Li [1 ]
Xu, Xiuli [1 ]
Bai, Qicai [2 ]
Xu, Hang [1 ]
Wang, Yutang [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Div Geriatr Cardiol 1, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Div Cardiol, Beijing, Peoples R China
关键词
optical coherence tomography; Sirolimus-eluting stent; neointimal coverage; malapposition; INTRAVASCULAR ULTRASOUND ANALYSIS; THROMBOSIS; PREDICTORS; OUTCOMES; MARKER;
D O I
10.1002/ccd.24497
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Late stent thrombosis related to delayed endothelialization is a major concern after drug-eluting stent (DES) implantation. The long-term vascular response towards DES implantation remains unclear. Optical coherence tomography (OCT) is a high-resolution imaging modality which provides new opportunities for evaluating neointimal coverage and stent strut apposition after stent implantation. Methods Fifty two patients who accepted 64 sirolimus-eluting stents (SESs, Cypher Select) were enrolled in the study. The OCT procedure was performed in 20 patients at 12 months (group 1), 17 patients at 24 months (group 2), and 15 patients at 48 months (group 3) after SESs implantation, respectively. The neointimal hyperplasia (NIH) thickness and stent strut apposition were assessed at 1-mm interval, and the presence of thrombus was observed in each stent. Results The NIH thickness was significantly higher at 48 months than that of 12 months (0.1694 +/- 0.1455 mm in G3 vs. 0.1455 +/- 0.1373 mm in G1, P < 0.01) and 24 months (0.1514 +/- 0.1296 mm in G2, P <0.01) after SESs implantation, but no significant difference existed between that of 12 months and 24 months (P > 0.05). Longer follow-up time was associated with significant decrease in the prevalence of uncovered struts (17.3% in group 1 vs. 8.8% in group 2 vs. 2.6% in group 3, P < 0.01) and malapposed struts (14.2% in group 1 vs. 10.3% in group 2 vs. 4.7% in group 3, P < 0.01). The incidence of intracoronary thrombus steadily decreased from 3.6% at 12 months to 2.4% at 24 months, and to 0.8% at 48 months (P < 0.01). Conclusion Neointimal growth continued for as long as 48 months after SES implantation. NIH thickness increased insignificantly from 12 to 24 months, but markedly increased at 48 months after stent implantation. Late neointimal growth was accompanied by a higher rate of covered struts and lower rate of malapposed stent struts. (c) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:768 / 775
页数:8
相关论文
共 30 条
[1]   Late incomplete stent apposition after sirolimus-eluting stent implantation - A serial intravascular ultrasound analysis [J].
Ako, J ;
Morino, Y ;
Honda, Y ;
Hassan, A ;
Sonoda, S ;
Yock, PG ;
Leon, MB ;
Moses, JW ;
Bonneau, HN ;
Fitzgerald, PJ .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (06) :1002-1005
[2]   Incomplete stent apposition and very late stent thrombosis after drug-eluting stent implantation [J].
Cook, Stephane ;
Wenaweser, Peter ;
Togni, Mario ;
Billinger, Michael ;
Morger, Cyrill ;
Seiler, Christian ;
Vogel, Rolf ;
Hess, Otto ;
Meier, Bernhard ;
Windecker, Stephan .
CIRCULATION, 2007, 115 (18) :2426-2434
[3]  
Cutlip DE, 2001, CIRCULATION, V103, P1967
[4]   Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice:: data from a large two-institutional cohort study [J].
Daemen, Joost ;
Wenaweser, Peter ;
Tsuchida, Keiichi ;
Abrecht, Linda ;
Sophia, Vaina ;
Morger, Cyrill ;
Kukreja, Neville ;
Jueni, Peter ;
Sianos, Georgios ;
Hellige, Gerrit ;
van Domburg, Ron T. ;
Hess, Otto M. ;
Boersma, Eric ;
Meier, Bernhard ;
Windecker, Stephan ;
Serruys, Patrick W. .
LANCET, 2007, 369 (9562) :667-678
[5]   Shear stress biology of the endothelium [J].
Davies, PF ;
Spaan, JA ;
Krams, R .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (12) :1714-1718
[6]   THE DYNAMIC-RESPONSE OF VASCULAR ENDOTHELIAL-CELLS TO FLUID SHEAR-STRESS [J].
DEWEY, CF ;
BUSSOLARI, SR ;
GIMBRONE, MA ;
DAVIES, PF .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1981, 103 (03) :177-185
[7]   Pathological correlates of late drug-eluting stent thrombosis - Strut coverage as a marker of endothelialization [J].
Finn, Aloke V. ;
Joner, Michael ;
Nakazawa, Gaku ;
Kolodgie, Frank ;
Newell, John ;
John, Mike C. ;
Gold, Herman K. ;
Virmani, Renu .
CIRCULATION, 2007, 115 (18) :2435-2441
[8]  
GUAGLIUMI GMG, 2008, AM J CARDIOL, V102
[9]   Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: Comparative sequential assessment with optical coherence tomography until complete resorption of the polymer [J].
Gutierrez-Chico, Juan Luis ;
Jueni, Peter ;
Garcia-Garcia, Hector M. ;
Regar, Evelyn ;
Nueesch, Eveline ;
Borgia, Francesco ;
van der Giessen, Willem J. ;
Davies, Simon ;
van Geuns, Robert Jan ;
Secco, Gioel Gabrio ;
Meis, Susanne ;
Windecker, Stephan ;
Serruys, Patrick W. ;
di Mario, Carlo .
AMERICAN HEART JOURNAL, 2011, 162 (05) :922-931
[10]   Late stent malapposition after drug-eluting stent implantation - An intravascular ultrasound analysis with long-term follow-up [J].
Hong, MK ;
Mintz, GS ;
Lee, CW ;
Park, DW ;
Park, KM ;
Lee, BK ;
Kim, YH ;
Song, JM ;
Han, KH ;
Kang, DH ;
Cheong, SS ;
Song, JK ;
Kim, JJ ;
Park, SW ;
Park, SJ .
CIRCULATION, 2006, 113 (03) :414-419