Endoleak detection after endovascular aneurysm repair using unenhanced MRI with flow suppression technique: Feasibility study in comparison with contrast-enhanced CT

被引:5
作者
Mori, Kensaku [1 ]
Saida, Tsukasa [1 ]
Sato, Fujio [2 ]
Uchikawa, Yoko [3 ]
Konishi, Takahiro [4 ]
Ishiguro, Toshitaka [4 ]
Hiyama, Takashi [4 ]
Hoshiai, Sodai [5 ]
Okamoto, Yoshikazu [1 ]
Nasu, Katsuhiro [1 ]
Minami, Manabu [1 ]
机构
[1] Univ Tsukuba, Dept Radiol, Fac Med, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
[2] Univ Tsukuba, Dept Cardiovasc Surg, Fac Med, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
[3] Hitachi Gen Hosp, Dept Radiol, 2-1-1 Jonancho, Hitachi, Ibaraki 3170077, Japan
[4] Univ Tsukuba Hosp, Dept Radiol, 2-1-1 Amakubo, Tsukuba, Ibaraki 3058576, Japan
[5] Ibaraki Cent Hosp, Dept Radiol, 6528 Koibuchi, Kasama, Ibaraki 3091793, Japan
关键词
Aortic aneurysm; Iliac aneurysm; Endovascular procedures; Endoleak; Magnetic resonance imaging; ABDOMINAL AORTIC-ANEURYSM; NEPHROGENIC SYSTEMIC FIBROSIS; COMPUTED-TOMOGRAPHY; HELICAL CT; GUIDELINES; ANGIOGRAPHY; GADOLINIUM; SURGERY; AGENT;
D O I
10.1007/s00330-016-4315-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the feasibility of unenhanced motion-sensitized-driven equilibrium (MSDE)-prepared balanced turbo field echo (BTFE) sequences for detecting endoleaks after endovascular aneurysm repair (EVAR). Forty-six patients treated with EVAR for aortic and/or iliac arterial aneurysms underwent contrast-enhanced CT and MSDE-prepared BTFE sequences with and without flow suppression. Two independent observers reviewed these sequences and their subtraction images and assigned confidence levels for detecting endoleaks. Relative contrast values were calculated by dividing signal intensities by those of paraspinal muscles. CT provided the reference standard. CT showed types I and II endoleaks in one and ten patients, respectively. Areas under receiver operating characteristic curves were 0.92 and 0.97 for observers 1 and 2, respectively. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of both observers were 91 (10/11), 91(32/35), 91 (42/46), 77 (10/13) and 97 % (32/33), respectively. Relative contrast values of endoleaks and flowing blood significantly decreased by flow suppression on MSDE-prepared BTFE images (P = 0.002 and P < 0.0001 respectively), and were significantly higher than those of the excluded aneurysms on subtraction images (P = 0.003 and P = 0.001, respectively). Unenhanced MSDE-prepared BTFE sequences are feasible for detecting endoleaks. aEuro cent Flow suppression significantly reduces endoleak signals on MSDE-prepared BTFE images. aEuro cent Subtraction images of MSDE-prepared BTFE sequences +/- flow suppression demonstrate endoleaks. aEuro cent MSDE-prepared BTFE sequences indicate high diagnostic values (> 90 %) except PPV (77 %). aEuro cent MSDE-prepared BTFE sequences need further refinement to reduce false positives. aEuro cent Endoleaks can be detected without contrast injection using MSDE-prepared BTFE sequences.
引用
收藏
页码:336 / 344
页数:9
相关论文
共 23 条
  • [1] Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms
    Alerci, Mario
    Oberson, Michel
    Fogliata, Antonella
    Gallino, Augusto
    Vock, Peter
    Wyttenbach, Rolf
    [J]. EUROPEAN RADIOLOGY, 2009, 19 (05) : 1223 - 1231
  • [2] Detection of Occult Endoleaks After Endovascular Treatment of Abdominal Aortic Aneurysm Using Magnetic Resonance Imaging With a Blood Pool Contrast Agent Preliminary Observations
    Cornelissen, Sandra A. P.
    Prokop, Mathias
    Verhagen, Hence J.
    Adriaensen, Miraude E.
    Moll, Frans L.
    Bartels, Lambertus W.
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (09) : 548 - 553
  • [3] Long-term comparison of thoracic endovascular aortic repair (TEVAR) to open surgery for the treatment of thoracic aortic aneurysms
    Desai, Nimesh D.
    Burtch, Kristen
    Moser, William
    Moeller, Pat
    Szeto, Wilson Y.
    Pochettino, Alberto
    Woo, Edward Y.
    Fairman, Ronald M.
    Bavaria, Joseph E.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (03) : 604 - 611
  • [4] Endovascular versus Open Repair of Abdominal Aortic Aneurysm
    Greenhalgh, Roger M.
    Brown, Louise C.
    Powell, Janet T.
    Thompson, Simon G.
    Epstein, David
    Sculpher, Mark J.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 362 (20) : 1863 - 1871
  • [5] Gadolinium - a specific trigger for the development of nephrogenic fibrosing dermopathy and nephrogenic systemic fibrosis?
    Grobner, T
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 (04) : 1104 - 1108
  • [6] High incidence of renal failure in patients with aortic aneurysms
    Hagiwara, Shinji
    Saima, Shigeki
    Negishi, Kousuke
    Takeda, Ryo
    Miyauchi, Naoko
    Akiyama, Yurika
    Horikoshi, Satoshi
    Tomino, Yasuhiko
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2007, 22 (05) : 1361 - 1368
  • [7] Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms
    Haulon, S
    Lions, C
    McFadden, EP
    Koussa, M
    Gaxotte, V
    Halna, P
    Beregi, JP
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2001, 22 (01) : 62 - 69
  • [8] Preliminary experience with superparamagnetic iron oxide-enhanced dynamic magnetic resonance imaging and comparison with contrast-enhanced computed tomography in endoleak detection after endovascular aneurysm repair
    Ichihashi, Shigeo
    Marugami, Nagaaki
    Tanaka, Toshihiro
    Iwakoshi, Shinichi
    Kurumatani, Norio
    Kitano, Satoru
    Nogi, Akihiro
    Kichikawa, Kimihiko
    [J]. JOURNAL OF VASCULAR SURGERY, 2013, 58 (01) : 66 - 72
  • [9] Contrast-enhanced ultrasound versus color duplex ultrasound imaging in the follow-up of patients after endovascular abdominal aortic aneurysm repair
    Iezzi, Roberto
    Basilico, Raffaella
    Giancristofaro, Daniela
    Pascali, Danilo
    Cotroneo, Antonio Raffaele
    Storto, Maria Luigia
    [J]. JOURNAL OF VASCULAR SURGERY, 2009, 49 (03) : 552 - 560
  • [10] MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA
    LANDIS, JR
    KOCH, GG
    [J]. BIOMETRICS, 1977, 33 (01) : 159 - 174