Early Outcomes of Intuity Rapid Deployment Aortic Valve Replacement Compared With Conventional Biological Valves in Japanese Patients

被引:4
作者
Ono, Yoshikazu [1 ]
Yajima, Shin [1 ]
Kainuma, Satoshi [1 ]
Kawamoto, Naonori [1 ]
Tadokoro, Naoki [1 ]
Kakuta, Takashi [1 ]
Koga-Ikuta, Ayumi [1 ]
Fujita, Tomoyuki [1 ]
Fukushima, Satsuki [1 ]
机构
[1] Natl Cerebral & Cardiovasc Ctr, Dept Cardiac Surg, 6-1 Kishibe Shinmachi, Suita, Osaka 5648565, Japan
关键词
Aortic valve replacement; Intuity; Rapid deployment; PROSPECTIVE MULTICENTER; MORTALITY; BIOPROSTHESIS; PERFORMANCE; MANAGEMENT; MISMATCH; IMPACT;
D O I
10.1253/circj.CJ-21-0959
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to elucidate the short-term surgical outcomes and hemodynamics of the Intuity valve compared to the standard bioprosthesis in Japanese patients. Methods and Results: Among the 307 consecutive patients who underwent aortic valve replacement (AVR) between February 2019 and March 2021, the Intuity valve was implanted in 95 patients (Intuity group) and a conventional stented bioprosthesis was implanted in 193 patients (conventional group). After propensity score matching, there was no significant difference in in-hospital mortality between the Intuity (n=2, 3%) and conventional groups (n=0, P=0.490). Operation, cardiopulmonary bypass, and aortic cross-clamping times were significantly shorter in the Intuity group. Although the effective orifice area index, trans-prosthetic mean pressure gradient, and peak velocity were similar between the 2 groups at 1 week postoperatively, the Intuity group showed a better mean pressure gradient and peak velocity at 1 year postoperatively. Complete atrioventricular block requiring permanent pacemaker implantation developed in 2 patients (3%) in the Intuity group and none in the conventional group (P=0.476). Mild or greater paravalvular leakage was present in 8 patients (13%) in the Intuity group and 2 patients (3%) in the conventional group (P=0.095). Conclusions: AVR using the Intuity valve in Japanese patients is satisfactory, with a better valve performance and a low incidence of complete atrioventricular block at 1 year postoperatively.
引用
收藏
页码:1710 / +
页数:12
相关论文
共 29 条
  • [1] Conventional versus rapid-deployment aortic valve replacement: a single-centre comparison between the Edwards Magna valve and its rapid-deployment successor
    Andreas, Martin
    Wallner, Stephanie
    Habertheuer, Andreas
    Rath, Claus
    Schauperl, Martin
    Binder, Thomas
    Beitzke, Dietrich
    Rosenhek, Raphael
    Loewe, Christian
    Wiedemann, Dominik
    Kocher, Alfred
    Laufer, Guenther
    [J]. INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2016, 22 (06) : 799 - 805
  • [2] Propensity-score matching in the cardiovascular surgery literature from 2004 to 2006: A systematic review and suggestions for improvement
    Austin, Peter C.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2007, 134 (05) : 1128 - U7
  • [3] Impact of valve prosthesis-patient mismatch on short-term mortality after aortic valve replacement
    Blais, C
    Dumesnil, JG
    Baillot, R
    Simard, S
    Doyle, D
    Pibarot, P
    [J]. CIRCULATION, 2003, 108 (08) : 983 - 988
  • [4] Aortic valve replacement in geriatric patients: Determinants of in-hospital mortality
    Bloomstein, LZ
    Gielchinsky, I
    Bernstein, AD
    Parsonnet, V
    Saunders, C
    Karanam, R
    Graves, B
    [J]. ANNALS OF THORACIC SURGERY, 2001, 71 (02) : 597 - 600
  • [5] Haemodynamic benefits of rapid deployment aortic valve replacement via a minimally invasive approach: 1-year results of a prospective multicentre randomized controlled trialaEuro
    Borger, Michael A.
    Dohmen, Pascal M.
    Knosalla, Christoph
    Hammerschmidt, Robert
    Merk, Denis R.
    Richter, Markus
    Doenst, Torsten
    Conradi, Lenard
    Treede, Hendrik
    Moustafine, Vadim
    Holzhey, David M.
    Duhay, Francis
    Strauch, Justus
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2016, 50 (04) : 713 - 720
  • [6] David I, 2020, INTERACT CARDIOVASC, V31, P1
  • [7] Relation between aortic cross-clamp time and mortality - not as straightforward as expected
    Doenst, Torsten
    Borger, Michael A.
    Weisel, Richard D.
    Yau, Terrence M.
    Maganti, Manjula
    Rao, Vivek
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) : 660 - 665
  • [8] The impact of gender on in-hospital mortality and morbidity after isolated aortic valve replacement
    Duncan, Andra Ibrahim
    Lin, Jia
    Koch, Colleen G.
    Gillinov, A. Marc
    Xu, Meng
    Starr, Norman J.
    [J]. ANESTHESIA AND ANALGESIA, 2006, 103 (04) : 800 - 808
  • [9] Eudailey KW, 2016, OPER TECH THORAC CAR, V21, P306
  • [10] Rapid-deployment aortic valve replacement versus standard bioprosthesis implantation
    Ferrari, Enrico
    Roduit, Christelle
    Salamin, Pauline
    Caporali, Elena
    Demertzis, Stefanos
    Tozzi, Piergiorgio
    Berdajs, Denis
    von Segesser, Ludwig
    [J]. JOURNAL OF CARDIAC SURGERY, 2017, 32 (06) : 322 - 327