Sliding multislice (SMS): A new technique for minimum FOV usage in axial continuously moving-table acquisitions

被引:24
作者
Fautz, HP
Kannengiesser, SAR
机构
[1] Univ Hosp Freiburg, Dept Diagnost Radiol Med Phys, D-79106 Freiburg, Germany
[2] Siemens Med Solut, MR Applicat Dev, Erlangen, Germany
关键词
continuously moving table; multislice; extended FOV; segmented k-space reordering; slice-phase encoding trajectory;
D O I
10.1002/mrm.20762
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A novel technique for axial continuously moving-table scans is described that minimizes the required extension of the scanner's field of view (FOV) along the direction of table motion (z) by applying a segmented multislice acquisition technique. Amy anatomical slice is acquired by applying the same phase-encoding steps at the same spatial positions along the scanner FOV. The full k-space data set of any anatomical slice is collected while the slice moves through the scanner from one scan position to the next. Simultaneous acquisition of multiple slices is realized by shifting the acquisition trajectories of different slices in time. It is demonstrated how the image artifact behavior that relates to varying imaging properties along the distance the table traverses during the acquisition of any given anatomical slice can be optimized simultaneously for all images. Discontinuities between the images along the slice axis are avoided because all z-dependent scan properties are encoded identically for all slices. Flexible spatial acquisition patterns are proposed to enable data oversampling and overlapping slice acquisitions at reduced table speeds. A framework of equations is presented by which matched parameter combinations for sliding multislice acquisitions can be applied to both single- and multiecho sequences. The new technique is validated on phantom and in vivo measurements using a T-1-weighted fast low-angle shot (FLASH) sequence as well as a T-2-weighted multispin-echo sequence of variable echo train lengths.
引用
收藏
页码:363 / 370
页数:8
相关论文
共 13 条
[1]   Whole-body MR imaging in 30 seconds with real-time true FISP and a continuously rolling table platform: Feasibility study [J].
Barkhausen, J ;
Quick, HH ;
Lauenstein, T ;
Goyen, M ;
Ruehm, SG ;
Laub, G ;
Debatin, JF ;
Ladd, ME .
RADIOLOGY, 2001, 220 (01) :252-256
[2]  
BRITTAIN JH, 2000, P 8 ANN M ISMRM DENV, P1726
[3]  
DIETRICH O, 1999, P 7 ANN M ISMRM PHIL, P1653
[4]   Signal behavior in continuously ramped 2D TrueFISP for whole-body imaging [J].
Fautz, HP ;
Leupold, J ;
Hennig, J ;
Scheffler, K .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :1085-1090
[5]   Homogeneous preparation encoding (HoPE) in multislice imaging [J].
Fautz, HP ;
Scheffler, K ;
Hennig, J .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (05) :745-752
[6]   Total-body MR imaging in as little as 18 seconds [J].
Johnson, KMR ;
Leavitt, GD ;
Kayser, HWM .
RADIOLOGY, 1997, 202 (01) :262-267
[7]   Continuously moving table data acquisition method for long FOV contrast-enhanced MRA and whole-body MRI [J].
Kruger, DG ;
Riederer, SJ ;
Grimm, RC ;
Rossman, PJ .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) :224-231
[8]  
LUDWIG U, 2004, P 12 ANN M ISMRM KYO, P2671
[9]   Time-resolved 3D contrast-enhanced MRA of an extended FOV using continuous table motion [J].
Madhuranthakam, AJ ;
Kruger, DG ;
Riederer, SJ ;
Glockner, JF ;
Hu, HCH .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :568-576
[10]   Correction for gradient nonlinearity in continuously moving table MR imaging [J].
Polzin, JA ;
Kruger, DG ;
Gurr, DH ;
Brittain, JH ;
Riederer, SJ .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (01) :181-187