Gold-enhanced biomolecular surface imaging of cells and tissue by SIMS and MALDI mass spectrometry

被引:209
作者
Altelaar, AFM
Klinkert, I
Jalink, K
de Lange, RPJ
Adan, RAH
Heeren, RMA
Piersma, SR
机构
[1] FOM, Inst Atom & Mol Phys, NL-1098 SJ Amsterdam, Netherlands
[2] Netherlands Canc Inst, Div Cell Biol, NL-1066 CX Amsterdam, Netherlands
[3] Univ Utrecht, Med Ctr, Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CG Utrecht, Netherlands
关键词
D O I
10.1021/ac0513111
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Surface metallization by plasma coating enhances desorption/ionization of membrane components such as lipids and sterols in imaging time-of-flight secondary ion mass spectrometry (TOF-SIMS) of tissues and cells. High-resolution images of cholesterol and other membrane components were obtained for neuroblastoma cells and revealed subcellular details (resolving power 1.5 mu m). Alternatively, in matrix-enhanced SIMS, 2,5-dihydroxybenzoic acid electrosprayed on neuroblastoma cells allowed intact molecular ion imaging of phosphatidylcholine and sphingomyelin at the cellular level. Gold deposition on top of matrix-coated rat brain tissue sections strongly enhanced image quality and signal intensity in stigmatic matrix-assisted laser desorption/ionization imaging mass spectrometry. High-quality total ion count images were acquired, and the neuropeptide vasopressin was localized in the rat brain tissue section at the hypothalamic area around the third ventricle. Although the mechanism of signal enhancement by gold deposition is under debate, the results we have obtained for cells and tissue sections illustrate the potential of this sample preparation technique for biomolecular surface imaging by mass spectrometry.
引用
收藏
页码:734 / 742
页数:9
相关论文
共 58 条
[1]   Matrix-enhanced secondary ion mass spectrometry: the influence of MALDI matrices on molecular ion yields of thin organic films [J].
Adriaensen, L ;
Vangaever, F ;
Lenaerts, J ;
Gijbels, R .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (08) :1017-1024
[2]   Metal-assisted secondary ion mass spectrometry: Influence of Ag and Au deposition on molecular ion yields [J].
Adriaensen, L ;
Vangaever, F ;
Gijbels, R .
ANALYTICAL CHEMISTRY, 2004, 76 (22) :6777-6785
[3]   Mass spectrometry-based proteomics [J].
Aebersold, R ;
Mann, M .
NATURE, 2003, 422 (6928) :198-207
[4]   Direct molecular Imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry [J].
Altelaar, AFM ;
van Minnen, J ;
Jiménez, CR ;
Heeren, RMA ;
Piersma, SR .
ANALYTICAL CHEMISTRY, 2005, 77 (03) :735-741
[5]  
ALTELAAR AFM, IN PRESS APPL SURF S
[6]   Comparative study of the metabolic pools of sphingomyelin and phosphatidylcholine sensitive to tumor necrosis factor [J].
Andrieu, N ;
Salvayre, R ;
Levade, T .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1996, 236 (02) :738-745
[7]  
Benninghoven A., 1987, SECONDARY ION MASS S
[8]   Selective hydrolysis of a mitochondrial pool of sphingomyelin induces apoptosis [J].
Birbes, H ;
El Bawab, S ;
Hannun, YA ;
Obeid, LM .
FASEB JOURNAL, 2001, 15 (14) :2669-2679
[9]   Molecular imaging of biological samples: Localization of peptides and proteins using MALDI-TOF MS [J].
Caprioli, RM ;
Farmer, TB ;
Gile, J .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4751-4760
[10]   Subcellular imaging by dynamic SIMS ion microscopy [J].
Chandra, S ;
Smith, DR ;
Morrison, GH .
ANALYTICAL CHEMISTRY, 2000, 72 (03) :104A-114A