LV mechanical dispersion as a predictor of ventricular arrhythmia in patients with advanced systolic heart failure A pilot study

被引:2
作者
Banasik, G. [1 ]
Segiet, O. [1 ]
Elwart, M. [1 ]
Szulik, M. [2 ]
Lenarczyk, R. [2 ]
Kalarus, Z. [2 ,3 ]
Kukulski, T. [2 ,3 ]
机构
[1] Med Univ Silesia, Sch Med, Div Dent Zabrze, Zabrze, Poland
[2] Silesian Ctr Heart Dis, Dept Cardiol Congenital Heart Dis & Electrotherap, Zabrze, Poland
[3] Med Univ Silesia, Katowice, Poland
关键词
CORONARY-ARTERY-DISEASE; SUDDEN CARDIAC DEATH; MYOCARDIAL-INFARCTION; EJECTION FRACTION; LONG-TERM; HIGH-RISK; DYSFUNCTION; REGISTRY; DEFIBRILLATOR; PREVENTION;
D O I
10.1007/s00059-015-4398-9
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myocardial mechanical dyssynchrony induced by the presence of postinfarction scar and/or conduction abnormalities in patients with a left ventricular ejection fraction (LVEF) of < 35 % may be associated with a greater propensity toward inducing serious ventricular arrhythmia [(ventricular tachycardia (VT), ventricular fibrillation (VF)] and sudden cardiac death. The assessment of regional myocardial function using tissue Doppler echocardiography (TDE) allows for noninvasive analysis of regional mechanical dysfunction (LV mechanical dispersion). The aim of this study was to evaluate the TDE-based mechanical dispersion as a potential echocardiographic predictor of VT/VF. The study group consisted of 47 consecutive ambulatory patients with implanted cardiac resynchronization therapy-defibrillator (CRT-D) devices who were divided into two groups: Group 1 (n = 29) comprised patients with recorded episodes of VT/VF, in whom baseline TDE data were available, and group 2 (n = 18) comprised patients without registered VT/VF in the device memory within 4 years after implantation. LV mechanical dispersion was defined as the standard deviation of the time measured from the beginning of the QRS complex to the peak longitudinal strain in apical four-chamber and two-chamber views. A retrospective quantitative assessment of LV regional deformation was based on the color tissue velocity recordings. The average time to event after implantation was 345 days. Patients with electrical events demonstrated greater mechanical dispersion: 99.14 +/- 33.60 vs. 72.98 +/- 19.70, p=0.002. During the 4-year follow-up, patients with documented VT/VF were characterized by significantly higher LV mechanical dispersion as compared with patients without electrical events. Measurement of LV mechanical dispersion might be helpful in determining the risk of sudden cardiac death.
引用
收藏
页码:599 / 604
页数:6
相关论文
共 50 条
  • [1] LV mechanical dispersion as a predictor of ventricular arrhythmia in patients with advanced systolic heart failure: A pilot study; [LV mechanische Dispersion als Prädiktor ventrikulärer Arrhythmie bei Patienten mit fortgeschrittener systolischer Herzinsuffizienz: Eine Pilotstudie]
    Banasik G.
    Segiet O.
    Elwart M.
    Szulik M.
    Lenarczyk R.
    Kalarus Z.
    Kukulski T.
    Herz, 2016, 41 (7) : 599 - 604
  • [2] Mechanical Dispersion Assessed by Myocardial Strain in Patients After Myocardial Infarction for Risk Prediction of Ventricular Arrhythmia
    Haugaa, Kristina H.
    Smedsrud, Marit Kristine
    Steen, Torkel
    Kongsgaard, Erik
    Loennechen, Jan Pal
    Skjaerpe, Terje
    Voigt, Jens-Uwe
    Willems, Rik
    Smith, Gunnar
    Smiseth, Otto A.
    Amlie, Jan P.
    Edvardsen, Thor
    JACC-CARDIOVASCULAR IMAGING, 2010, 3 (03) : 247 - 256
  • [3] Risk stratification of ventricular arrhythmias in patients with systolic heart failure
    Vest, Richard N., III
    Gold, Michael R.
    CURRENT OPINION IN CARDIOLOGY, 2010, 25 (03) : 268 - 275
  • [4] An Impaired Renal Function: A Predictor of Ventricular Arrhythmia and Mortality in Patients with Nonischemic Cardiomyopathy and Heart Failure
    Kreuz, Jens
    Horlbeck, Fritz
    Hoyer, Felix
    Mellert, Fritz
    Fimmers, Rolf
    Lickfett, Lars
    Nickenig, Georg
    Schwab, Joerg O.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (07): : 894 - 899
  • [5] Right Ventricular Systolic Pressure Trajectory as a Predictor of Hospitalization and Mortality in Patients With Chronic Heart Failure
    Kotrri, Gynter
    Youngson, Erik
    Fine, Nowell M.
    Howlett, Jonathan G.
    Lyons, Kristin
    Paterson, D. Ian
    Ezekowitz, Justin
    Mcalister, Finlay A.
    Miller, Robert J. H.
    CJC OPEN, 2023, 5 (09) : 671 - 679
  • [6] Global longitudinal strain for prediction of ventricular arrhythmia in patients with heart failure
    Nikoo, Mohammad Hossein
    Naeemi, Razieh
    Moaref, Alireza
    Attar, Armin
    ESC HEART FAILURE, 2020, 7 (05): : 2956 - 2961
  • [7] Impact of Improved Left Ventricular Systolic Function on the Recurrence of Ventricular Arrhythmia in Heart Failure Patients With an Implantable Cardioverter-Defibrillator
    Kim, Minsu
    Kim, Jun
    Lee, Ji Hyun
    Hwang, You Mi
    Kim, Min-Seok
    Nam, Gi-Byoung
    Choi, Kee-Joon
    Kim, Jae-Joong
    Kim, You-Ho
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (10) : 1191 - 1198
  • [8] Racial differences in mortality in patients with advanced systolic heart failure: Potential role of right ventricular ejection fraction
    White, Michel
    Patel, Kanan
    Caldentey, Guillem
    Deedwania, Prakash
    Kheirbek, Raya
    Fletcher, Ross D.
    Aban, Inmaculada B.
    Lo, Alexander
    Aronow, Wilbert S.
    Fonarow, Gregg C.
    Anker, Stefan D.
    Ahmed, Ali
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2014, 177 (01) : 255 - 260
  • [9] Atrial resynchronization therapy in patients with atrial fibrillation and heart failure with and without systolic left ventricular dysfunction: a pilot study
    Saksena, Sanjeev
    Slee, April
    Saad, Marwan
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2018, 53 (01) : 9 - 17
  • [10] Prognostic Value of Left Ventricular End-Systolic Volume Index as a Predictor of Heart Failure Hospitalization in Stable Coronary Artery Disease: Data from the Heart and Soul Study
    McManus, David D.
    Shah, Sanjiv J.
    Fabi, Mary Rose
    Rosen, Alisa
    Whooley, Mary A.
    Schiller, Nelson B.