Regional lung perfusion:: Assessment with partially parallel three-dimensional MR imaging

被引:87
作者
Fink, C
Puderbach, M
Bock, M
Lodemann, KP
Zuna, I
Schmähl, A
Delorme, S
Kauczor, HU
机构
[1] Deutsch Krebsforschungszentrum, Dept Radiol, Innovat Krebsdiagnost & Therapie, D-69120 Heidelberg, Germany
[2] Deutsch Krebsforschungszentrum, Dept Med Phys Radiol, Innovat Krebsdiagnost & Therapie, D-69120 Heidelberg, Germany
[3] Deutsch Krebsforschungszentrum, Dept Radiat Therapy, Innovat Krebsdiagnost & Therapie, D-69120 Heidelberg, Germany
[4] Bracco Atlana Pharma, Constance, Germany
[5] Thoraxklin Heidelberg Germany, Heidelberg, Germany
关键词
lung; MR; perfusion; lung neoplasms; radionuclide studies; magnetic resonance (MR); perfusion study;
D O I
10.1148/radiol.2311030193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate partially parallel three-dimensional (3D) magnetic resonance (MR) imaging for assessment of regional lung perfusion in healthy volunteers and patients suspected of having lung cancer or metastasis. MATERIALS AND METHODS: Seven healthy volunteers and 20 patients suspected of having lung cancer or metastasis were examined with 3D gradient-echo MR imaging with partially parallel image acquisitions (fast low-angle shot 3D imaging; repetition time msec/echo time msec, 1.9/0.8; flip angle, 40degrees; acceleration factor, two; number of reference k-space lines for calibration, 24; field of view, 500 x 440 mm; matrix, 256 X 123; slab thickness, 160 mm; number of partitions, 32; voxel size, 3.6 X 2.0 x 5.0 mm(3); acquisition time, 1.5 seconds) after administration of 0.1 mmol/kg of gadobenate dimeglumine. In volunteers, 3D MR perfusion data sets were assessed for topographic and temporal distribution of regional lung perfusion. Sensitivity, specificity, accuracy, and positive and negative predictive values for perfusion MR imaging for detecting perfusion abnormalities in patients were calculated, with conventional radionuclide perfusion scintigraphy as the standard of reference. Interobserver and intermodality agreement was determined by using K statistics. RESULTS: Topographic analysis of lung perfusion in volunteers revealed a significantly higher signal-to-noise ratio (SNR) of up to 327% in gravity-dependent lung areas. Temporal analysis similarly revealed much shorter lag time to peak enhancement in gravity-dependent lung areas. In patients, perfusion MR imaging achieved high sensitivity (88%-94%), specificity (100%), and accuracy (90%-95%) for detection of perfusion abnormalities. Interobserver agreement (kappa = 0.86) was very good and intermodality agreement (kappa = 0.69-0.83) was good to very good for detection of perfusion defects. A significant difference (P < .0001) in SNR was observed between normally perfused lung (14 +/- 7 [SD]) and perfusion defects (7 +/- 4) in patients. CONCLUSION: Partially parallel MR imaging with high spatial and temporal resolution allows assessment of regional lung perfusion and has high diagnostic accuracy for detecting perfusion abnormalities. (C) RSNA, 2004.
引用
收藏
页码:175 / 184
页数:10
相关论文
共 29 条
  • [1] Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging - Application to unilateral lung transplantation
    Berthezene, Y
    Croisille, P
    Bertocchi, M
    Houzard, C
    Bendib, K
    Revel, D
    [J]. INVESTIGATIVE RADIOLOGY, 1997, 32 (06) : 351 - 356
  • [2] Bock M, 2000, MAGNET RESON MED, V43, P481, DOI 10.1002/(SICI)1522-2594(200003)43:3<481::AID-MRM21>3.0.CO
  • [3] 2-N
  • [4] Nuclear medicine procedures in lung cancer
    Chiti, A
    Schreiner, FAG
    Crippa, F
    Pauwels, EKJ
    Bombardieri, E
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1999, 26 (05) : 533 - 555
  • [5] CLINICAL VENTILATION-PERFUSION SCINTIGRAPHY
    FAZIO, F
    WOLLMER, P
    [J]. CLINICAL PHYSIOLOGY, 1981, 1 (04): : 323 - 337
  • [6] FISHMAN AP, 1963, HDB PHYSL 2, P1688
  • [7] Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA)
    Griswold, MA
    Jakob, PM
    Heidemann, RM
    Nittka, M
    Jellus, V
    Wang, JM
    Kiefer, B
    Haase, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) : 1202 - 1210
  • [8] THE RICIAN DISTRIBUTION OF NOISY MRI DATA
    GUDBJARTSSON, H
    PATZ, S
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (06) : 910 - 914
  • [9] Pulmonary perfusion: Qualitative assessment with dynamic contrast-enhanced MRI using ultra-short TE and inversion recovery turbo FLASH
    Hatabu, H
    Gaa, J
    Kim, D
    Li, W
    Prasad, PV
    Edelman, RR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (04) : 503 - 508
  • [10] Hatabu H, 1999, MAGNET RESON MED, V42, P1033, DOI 10.1002/(SICI)1522-2594(199912)42:6<1033::AID-MRM7>3.0.CO