Current Review: Multifocal Intraocular Lenses and Extended Depth of Focus Intraocular Lenses

被引:9
作者
Breyer, Detlev R. H. [1 ,2 ,3 ]
Beckers, Lena [1 ,2 ,3 ]
Ax, Timon [1 ,2 ,3 ]
Kaymak, Hakan [1 ,2 ,3 ]
Klabe, Karsten [1 ,2 ,3 ]
Kretz, Florian Tobias Alwin [3 ,4 ]
机构
[1] Breyer Kaymak & Klabe Augenchirurg, Dusseldorf, Germany
[2] Int Innovat Ophthalmochirurg, IIO, Dusseldorf, Germany
[3] Heidelberg Univ, Int Vis Correct Res Ctr Network IVCRC Net, Augenheilkunde, Heidelberg, Germany
[4] PVK Precise Vis GmbH, Precise Vis Augenarzte, Augenheilkunde, Rheine, Germany
关键词
presbyopia; refractive surgery; cataract; OPTICAL BENCH PERFORMANCE; MIX-AND-MATCH; VISUAL OUTCOMES; BILATERAL IMPLANTATION; PATIENT SATISFACTION; CLINICAL-OUTCOMES; DEFOCUS CURVES; HALO SIZE; CATARACT; QUALITY;
D O I
10.1055/a-1111-9380
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Presbyopia and cataract patients' wish to be increasingly independent of spectacles after surgery and this is one of the main drivers for the development of multifocal intraocular lenses (MIOL) and extended depth of focus (EDOF) intraocular lenses (IOL). As education, biometry, diagnostics, surgical techniques, and MIOL/EDOF IOL designs have improved over the past decade, an increasing number of cataract surgeons have become cataract refractive surgeons to help address this need. There is not one single MIOL/EDOF IOL, however, that suits all patients' needs. The wide variety of MIOL and EDOF IOL, their optics, and their impact on our patients' quality of vision have to be fully understood if we have to choose the appropriate IOL for each individual; MIOL/EDOF IOL surgery has to be customized. This review article looks at the different optical aspects and clinical consequences of MIOL/EDOF IOL, in order to help surgeons find an appropriate solution for each of their individual patients.
引用
收藏
页码:943 / 957
页数:15
相关论文
共 83 条
[1]   Clinical outcomes of a new diffractive trifocal intraocular lens with Enhanced Depth of Focus (EDOF) [J].
Acar, Banu Torun ;
Duman, Erkan ;
Simsek, Saban .
BMC OPHTHALMOLOGY, 2016, 16
[2]   Distance and Near Visual Acuity Improvement After Implantation of Multifocal Intraocular Lenses in Cataract Patients With Presbyopia: A Systematic Review [J].
Agresta, Blaise ;
Knorz, Michael C. ;
Kohnen, Thomas ;
Donatti, Christina ;
Jackson, Daniel .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (06) :426-435
[3]   Preclinical metrics to predict through-focus visual acuity for pseudophakic patients [J].
Alarcon, Aixa ;
Canovas, Carmen ;
Rosen, Robert ;
Weeber, Henk ;
Tsai, Linda ;
Hileman, Kendra ;
Piers, Patricia .
BIOMEDICAL OPTICS EXPRESS, 2016, 7 (05) :1877-1888
[4]  
Alba-Bueno F, 2014, Arch Soc Esp Oftalmol, V89, P397, DOI 10.1016/j.oftal.2014.01.002
[5]   Visual outcomes with a single-optic accommodating intraocular lens and a low-addition-power rotational asymmetric multifocal intraocular lens [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Montalban, Raul ;
Javaloy, Jaime .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06) :978-985
[6]   Comparison of the Visual and Intraocular Optical Performance of a Refractive Multifocal IOL With Rotational Asymmetry and an Apodized Diffractive Multifocal IOL [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Javaloy, Jaime ;
Ayala, Maria Jose .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (02) :100-U84
[7]   Comparative analysis of the clinical outcomes with 2 multifocal intraocular lens models with rotational asymmetry [J].
Alio, Jorge L. ;
Plaza-Puche, Ana B. ;
Pinero, David P. ;
Javaloy, Jaime ;
Jose Ayala, Maria .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (09) :1605-1614
[8]   FRESNEL LENSES [J].
ANICIN, BA ;
BABOVIC, VM ;
DAVIDOVIC, DM .
AMERICAN JOURNAL OF PHYSICS, 1989, 57 (04) :312-316
[9]   Visual Performance of a New Bi-aspheric, Segmented, Asymmetric Multifocal IOL [J].
Berrow, Emma J. ;
Wolffsohn, James S. ;
Bilkhu, Paramdeep S. ;
Dhallu, Sandeep ;
Naroo, Shehzad A. ;
Shah, Sunil .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (09) :584-U10
[10]  
Born M, 1975, PRINCIPLES OPTICS, P5